A Parametric Level Set Method for Electrical Impedance Tomography.

Dong Liu, Anil Kumar Khambampati, Jiangfeng Du.   

Abstract

This paper presents an image reconstruction method based on parametric level set (PLS) method using electrical impedance tomography. The conductivity to be reconstructed was assumed to be piecewise constant and the geometry of the anomaly was represented by a shape-based PLS function, which we represent using Gaussian radial basis functions (GRBF). The representation of the PLS function significantly reduces the number of unknowns, and circumvents many difficulties that are associated with traditional level set (TLS) methods, such as regularization, re-initialization and use of signed distance function. PLS reconstruction results shown in this article are some of the first ones using experimental EIT data. The performance of the PLS method was tested with water tank data for two-phase visualization and with simulations which demonstrate the most popular biomedical application of EIT: lung imaging. In addition, robustness studies of the PLS method w.r.t width of the Gaussian function and GRBF centers were performed on simulated lung imaging data. The experimental and simulation results show that PLS method has significant improvement in image quality compared with the TLS reconstruction.

Entities:  

Mesh:

Year:  2017        PMID: 28952939     DOI: 10.1109/TMI.2017.2756078

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  5 in total

1.  An In Situ Electrical Impedance Tomography Sensor System for Biomass Estimation of Tap Roots.

Authors:  Rinku Basak; Khan A Wahid
Journal:  Plants (Basel)       Date:  2022-06-28

2.  Reconstruction of conductivity distribution with electrical impedance tomography based on hybrid regularization method.

Authors:  Yanyan Shi; Xiaoyue He; Meng Wang; Bin Yang; Feng Fu; Xiaolong Kong
Journal:  J Med Imaging (Bellingham)       Date:  2021-06-17

3.  Improved resolution of D-bar images of ventilation using a Schur complement property and an anatomical atlas.

Authors:  Talles Batista Rattis Santos; Rafael Mikio Nakanishi; Erick Dario León Bueno de Camargo; Marcelo Brito Passos Amato; Jari P Kaipio; Raul Gonzalez Lima; Jennifer L Mueller
Journal:  Med Phys       Date:  2022-05-05       Impact factor: 4.506

4.  Introduction of Sample Based Prior into the D-Bar Method Through a Schur Complement Property.

Authors:  Talles Batista Rattis Santos; Rafael Mikio Nakanishi; Jari P Kaipio; Jennifer L Mueller; Raul Gonzalez Lima
Journal:  IEEE Trans Med Imaging       Date:  2020-11-30       Impact factor: 11.037

5.  Focusing Sensor Design for Open Electrical Impedance Tomography Based on Shape Conformal Transformation.

Authors:  Yu Wang; Shangjie Ren; Feng Dong
Journal:  Sensors (Basel)       Date:  2019-05-02       Impact factor: 3.576

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.