Literature DB >> 28951640

Minimally invasive plate osteosynthesis on anterior pelvic ring injury and anterior column acetabular fracture.

Hadisoebroto Dilogo Ismail1, Yoshi Pratama Djaja1, Jessica Fiolin1.   

Abstract

INTRODUCTION: In performing surgery for fractures of the pelvis and acetabulum, various surgical approaches have been introduced with their own advantages and drawbacks. The extensile nature of ilioinguinal approach gives excellent exposure but was related to wound healing problems. Modified stoppa has a higher difficulty and poses a risk for neurovascular injury. In this study, we elaborate our experience using the Modified Stoppa approach with additional lateral window while adding few modifications to simplify the procedure and facilitate future implant removal.
METHODS: A prospective-retrospective cohort involving 30 anterior pelvic ring and/or anterior column acetabulum fracture patients were conducted from 2012-2016. Fifteen cases were prospectively treated using the modified approach since 2014, while the remaining fifteen cases that were treated using Ilioinguinal approach were retrospectively reviewed. Intraoperative parameters such as blood loss, duration of surgery, quality of reduction (Matta) and postoperative functional outcome (Majeed and Hannover score) at 12 months period were recorded and evaluated by a blinded reviewer. RESULT: There were no significant differences between the two groups in mean age, sex and fracture type. The mean blood loss in the MIPO group were 325 ± 225 mL versus 710.67 ± 384.51 mL in the control group (p = 0.002). Duration of surgery were 149.33 ± 91.92 minutes in MIPO group versus 235.71 ± 65.79 minutes in ilioinguinal group (p = 0.014). There were no significant differences noted between the two groups in the quality of reduction and postoperative functional outcome, either by using Majeed or Hannover pelvic score. No complications were found after a 12-months follow up period. Two modified cases already had their implant removed and during the procedure, fibrotic tissue were minimal making the implant removal was less complicated and easier.
CONCLUSIONS: Modified stoppa and lateral window technique can be used as a safe and effective alternative approach for anterior pelvic ring fracture and/or anterior column acetabulum fracture. This approach decreased the duration of surgery and blood loss without compromising the quality of reduction and functional outcome in patients.

Entities:  

Keywords:  Acetabular fracture; Anterior column; MIPO; Modified stoppa and lateral window; Pelvic fracture

Year:  2017        PMID: 28951640      PMCID: PMC5605749          DOI: 10.1016/j.jcot.2017.06.007

Source DB:  PubMed          Journal:  J Clin Orthop Trauma        ISSN: 0976-5662


  29 in total

1.  Fractures of the acetabulum: accuracy of reduction and clinical results in patients managed operatively within three weeks after the injury.

Authors:  J M Matta
Journal:  J Bone Joint Surg Am       Date:  1996-11       Impact factor: 5.284

2.  Minimally invasive ilioinguinal approach to the acetabulum.

Authors:  H Wolf; T Wieland; G Pajenda; V Vécsei; M Mousavi
Journal:  Injury       Date:  2006-09-18       Impact factor: 2.586

3.  Internal fixation of unstable pelvic ring injuries.

Authors:  J M Matta; P Tornetta
Journal:  Clin Orthop Relat Res       Date:  1996-08       Impact factor: 4.176

4.  Anterior intrapelvic modification to the ilioinguinal approach.

Authors:  Jennifer E Hagen; Brian M Weatherford; Jason W Nascone; Marcus F Sciadini
Journal:  J Orthop Trauma       Date:  2015-02       Impact factor: 2.512

5.  The two-incision, minimally invasive approach in the treatment of acetabular fractures.

Authors:  Steffen Ruchholtz; Benjamin Buecking; Anne Delschen; Ulrike Lewan; Georg Taeger; Christian Kuehne; Ralph Zettl
Journal:  J Orthop Trauma       Date:  2013-05       Impact factor: 2.512

6.  Operative treatment of acetabular fractures through the ilioinguinal approach. A 10-year perspective.

Authors:  J M Matta
Journal:  Clin Orthop Relat Res       Date:  1994-08       Impact factor: 4.176

7.  Corona mortis: incidence and location.

Authors:  Lokman Karakurt; Ilgin Karaca; Erhan Yilmaz; Oktay Burma; Erhan Serin
Journal:  Arch Orthop Trauma Surg       Date:  2002-01-17       Impact factor: 3.067

8.  The anterior intra-pelvic (modified rives-stoppa) approach for fixation of acetabular fractures.

Authors:  H Claude Sagi; Alan Afsari; Daniel Dziadosz
Journal:  J Orthop Trauma       Date:  2010-05       Impact factor: 2.512

9.  Modified and new approaches for pelvic and acetabular surgery.

Authors:  Eero Hirvensalo; Jan Lindahl; Veikko Kiljunen
Journal:  Injury       Date:  2007-04       Impact factor: 2.586

Review 10.  The treatment of acetabular fractures through the ilioinguinal approach.

Authors:  E Letournel
Journal:  Clin Orthop Relat Res       Date:  1993-07       Impact factor: 4.176

View more
  7 in total

1.  Complications of surgical approaches for stabilization of pelvic ring injuries: Analysis of pitfalls and how to avoid them.

Authors:  Markus A Küper; Alexander Trulson; Fabian M Stuby; Ulrich Stöckle; Christian Konrads
Journal:  J Orthop       Date:  2020-05-11

2.  The influence of bone quality on radiological outcome in 50 consecutive acetabular fractures treated with a pre-contoured anatomic suprapectineal plate.

Authors:  Maximilian J Hartel; Tareq Naji; Florian Fensky; Frank O Henes; Darius M Thiesen; Wolfgang Lehmann; Karl-Heinz Frosch; Dimitris Ntalos
Journal:  Arch Orthop Trauma Surg       Date:  2021-03-24       Impact factor: 2.928

3.  Conventional plate fixation versus minimally invasive modified pedicle screw-rod fixation for anterior pelvic ring fractures.

Authors:  Yao-Tung Tsai; Chun-Liang Hsu; Chun-Chi Hung; Yu-Ching Chou; Chia-Chun Wu; Tsu-Te Yeh
Journal:  PLoS One       Date:  2019-04-08       Impact factor: 3.240

4.  Minimally Invasive Percutaneous TightRope® System Fixation for an Unstable Posterior Pelvic Ring: Clinical Follow-up and Biomechanical Studies.

Authors:  Feng Gu; Jiting Zhang; Zhenjiang Sui; Ke Zhang; Xiaoping Xie; Tiecheng Yu
Journal:  Orthop Surg       Date:  2022-04-26       Impact factor: 2.279

5.  Digital Anatomy to Improve Screw Insertion Techniques for Plate-Screw Fixation of the Pubic Body.

Authors:  Wenlong Li; Futing Zhao; Zhaoyun Sun; Xing Wang; Shenglong Gao; Bo Xu; Weidong Mu
Journal:  Biomed Res Int       Date:  2018-12-12       Impact factor: 3.411

6.  Meta-analysis of modified Stoppa approach and ilioinguinal approach in anterior pelvic ring and acetabular fractures.

Authors:  Hao Wu; LiJun Zhang; XiaoMin Guo; XiaoJun Jiang
Journal:  Medicine (Baltimore)       Date:  2020-01       Impact factor: 1.817

7.  Clinical research on minimally invasive internal fixation for the treatment of anterior ring injury in tile C pelvic fracture.

Authors:  Xiaochen Sun; Huimin Yan; Jianmin Wang; Zhaojie Liu; Wei Tian; Jian Jia
Journal:  Medicine (Baltimore)       Date:  2020-07-24       Impact factor: 1.817

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.