Literature DB >> 28951267

Effectiveness and Limitations of Intraoperative Monitoring with Combined Motor and Somatosensory Evoked Potentials During Surgical Clipping of Unruptured Intracranial Aneurysms.

Hyun Ho Choi1, Eun Jin Ha2, Won-Sang Cho3, Hyun-Seung Kang2, Jeong Eun Kim2.   

Abstract

OBJECTIVE: Postoperative neurologic deficits are one of the devastating complications that can result from surgical clipping of unruptured intracranial aneurysms. Intraoperative monitoring (IOM) of motor and somatosensory evoked potentials (EPs) has been used to reduce neurologic sequelae. We evaluated the effectiveness and limitations of IOM in prevention of surgical complications during aneurysm clipping.
METHODS: A retrospective analysis was performed, involving 386 operations for 429 unruptured intracranial aneurysms in 386 patients with consecutively collected IOM data.
RESULTS: Significant EP changes were detected during clipping of 23 aneurysms in 23 patients (5.4% of aneurysms). Among them, 8 patients (accounting for 2.1% of operations and 1.9% of aneurysms) experienced postoperative motor deficits, including 3 permanent and 5 temporary motor deficits with corresponding radiologic lesions. In detecting postoperative motor deficits, the sensitivity and specificity of motor EP monitoring were 0.38 and 0.99, respectively, and those of somatosensory EP monitoring were 0.25 and 0.96, respectively. Seven patients (1.8% of operations) with unchanged EPs had other kinds of postoperative neurologic complications, including altered mentality in 5 cases, motor aphasia in 1, and gaze limitation in 1, with corresponding radiologic abnormalities. However, all 7 patients with other neurologic symptoms recovered within 6 months after surgery.
CONCLUSIONS: IOM of motor and somatosensory EPs was useful and reliable in predicting and preventing postoperative motor deficits. However, it also showed some limitations in the significance of positive EP changes and detection of neurologic deficits other than motor function.
Copyright © 2017 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Clipping; Intraoperative monitoring; Postoperative neurologic deficits; Unruptured intracranial aneurysms

Mesh:

Year:  2017        PMID: 28951267     DOI: 10.1016/j.wneu.2017.09.096

Source DB:  PubMed          Journal:  World Neurosurg        ISSN: 1878-8750            Impact factor:   2.104


  2 in total

1.  Prediction of postoperative motor deficits using intraoperative motor-evoked potentials in middle cerebral artery aneurysm.

Authors:  Dongze Guo; Xing Fan; Hao You; Xiaorong Tao; Lei Qi; Miao Ling; Zhibao Li; Jiajia Liu; Hui Qiao
Journal:  Neurosurg Rev       Date:  2020-01-22       Impact factor: 3.042

2.  Usefulness of Intraoperative Neurophysiological Monitoring During the Clipping of Unruptured Intracranial Aneurysm: Diagnostic Efficacy and Detailed Protocol.

Authors:  Dougho Park; Byung Hee Kim; Sang-Eok Lee; Eunhwan Jeong; Kwansang Cho; Ji Kang Park; Yeon-Ju Choi; Suntak Jin; Daeyoung Hong; Mun-Chul Kim
Journal:  Front Surg       Date:  2021-02-26
  2 in total