Device Management in Heart Failure.

Brett G Angel1, Heath Saltzman2, Luke S Kusmirek2.   

Abstract

PURPOSE OF REVIEW: Medical devices have become an integral part of comprehensive heart failure management. Not all heart failure patients, however, accrue benefit from every new device, and even with extensive practice guidelines, this remains an evolving field. RECENT
FINDINGS: The addition of implantable devices, like internal cardioverter defibrillators (ICDs), and novel pacing technologies, including cardiac resynchronization therapy (CRT), have helped to compliment goal-directed medical therapy and positively impact prognosis in multiple high-quality clinical trials. This review attempts to summarize the rapidly evolving literature with respect to existing device guidelines for routine implantable devices as well as some available and future technologies that are not yet a part of routine guidelines. ICD, CRT, and other implantable devices continue to save lives, decrease hospitalizations, and evolve the management of patients with heart failure beyond the capabilities of optimal guideline-directed medical therapy alone.

Entities:  

Keywords:  Cardiac resynchronization therapy (CRT); Dyssynchrony; Internal cardioverter defibrillator (ICD); Left bundle branch block (LBBB); Sudden cardiac death (SCD); Systolic heart failure; Ventricular tachycardia and fibrillation

Mesh:

Year:  2017        PMID: 28948481     DOI: 10.1007/s11886-017-0914-2

Source DB:  PubMed          Journal:  Curr Cardiol Rep        ISSN: 1523-3782            Impact factor:   2.931


  93 in total

1.  Sudden death in heart failure: vascular or electrical?

Authors:  J G Cleland; B M Massie; M Packer
Journal:  Eur J Heart Fail       Date:  1999-03       Impact factor: 15.534

2.  Randomized comparison of antiarrhythmic drug therapy with implantable defibrillators in patients resuscitated from cardiac arrest : the Cardiac Arrest Study Hamburg (CASH).

Authors:  K H Kuck; R Cappato; J Siebels; R Rüppel
Journal:  Circulation       Date:  2000-08-15       Impact factor: 29.690

3.  Time dependence of defibrillator benefit after coronary revascularization in the Multicenter Automatic Defibrillator Implantation Trial (MADIT)-II.

Authors:  Ilan Goldenberg; Arthur J Moss; Scott McNitt; Wojciech Zareba; W Jackson Hall; Mark L Andrews; David J Wilber; Helmut U Klein
Journal:  J Am Coll Cardiol       Date:  2006-04-17       Impact factor: 24.094

Review 4.  Atrial fibrillation and congestive heart failure: specific considerations at the intersection of two common and important cardiac disease sets.

Authors:  Joachim R Ehrlich; Stanley Nattel; Stefan H Hohnloser
Journal:  J Cardiovasc Electrophysiol       Date:  2002-04

5.  A comparison of antiarrhythmic-drug therapy with implantable defibrillators in patients resuscitated from near-fatal ventricular arrhythmias.

Authors: 
Journal:  N Engl J Med       Date:  1997-11-27       Impact factor: 91.245

6.  Canadian implantable defibrillator study (CIDS) : a randomized trial of the implantable cardioverter defibrillator against amiodarone.

Authors:  S J Connolly; M Gent; R S Roberts; P Dorian; D Roy; R S Sheldon; L B Mitchell; M S Green; G J Klein; B O'Brien
Journal:  Circulation       Date:  2000-03-21       Impact factor: 29.690

7.  Effect of QRS duration and morphology on cardiac resynchronization therapy outcomes in mild heart failure: results from the Resynchronization Reverses Remodeling in Systolic Left Ventricular Dysfunction (REVERSE) study.

Authors:  Michael R Gold; Christophe Thébault; Cecilia Linde; William T Abraham; Bart Gerritse; Stefano Ghio; Martin St John Sutton; Jean-Claude Daubert
Journal:  Circulation       Date:  2012-07-10       Impact factor: 29.690

8.  Discrimination of ventricular tachycardia from sinus tachycardia and atrial fibrillation in a tiered-therapy cardioverter-defibrillator.

Authors:  C D Swerdlow; P S Chen; R M Kass; J R Allard; C T Peter
Journal:  J Am Coll Cardiol       Date:  1994-05       Impact factor: 24.094

9.  Implantable cardioverter defibrillator compared with antiarrhythmic drug treatment in cardiac arrest survivors (the Cardiac Arrest Study Hamburg).

Authors:  J Siebels; K H Kuck
Journal:  Am Heart J       Date:  1994-04       Impact factor: 4.749

10.  Prophylactic defibrillator implantation in patients with nonischemic dilated cardiomyopathy.

Authors:  Alan Kadish; Alan Dyer; James P Daubert; Rebecca Quigg; N A Mark Estes; Kelley P Anderson; Hugh Calkins; David Hoch; Jeffrey Goldberger; Alaa Shalaby; William E Sanders; Andi Schaechter; Joseph H Levine
Journal:  N Engl J Med       Date:  2004-05-20       Impact factor: 91.245

View more
  1 in total

1.  Left ventricular lead misplacement discovered a decade after cardiac resynchronization therapy-defibrillator implantation: a case report.

Authors:  Lisa W M Leung; Banu Evranos; Rajay Narain; Mark M Gallagher
Journal:  Eur Heart J Case Rep       Date:  2018-06-21