| Literature DB >> 28943759 |
Juri Lee1, Cheol Woo Lee1, Hae In Yong2, Hyun Jung Lee2, Cheorun Jo2,3, Samooel Jung1.
Abstract
Novel, effective methods to control and prevent spoilage and contamination by pathogenic microorganisms in meat and meat products are in constant demand. Non-thermal pasteurization is an ideal method for the preservation of meat and meat products because it does not use heat during the pasteurization process. Atmospheric pressure cold plasma (APCP) is a new technology for the non-thermal pasteurization of meat and meat products. Several recent studies have shown that APCP treatment reduces the number of pathogenic microorganisms in meat and meat products. Furthermore, APCP treatment can be used to generate nitrite, which is an essential component of the curing process. Here, we introduce the effectiveness of APCP treatment as a pasteurization method and/or curing process for use in the meat and meat product processing industry.Entities:
Keywords: atmospheric pressure cold plasma; meat; meat products; nitrite; pasteurization
Year: 2017 PMID: 28943759 PMCID: PMC5599567 DOI: 10.5851/kosfa.2017.37.4.477
Source DB: PubMed Journal: Korean J Food Sci Anim Resour ISSN: 1225-8563 Impact factor: 2.622
Fig. 1.Plasma classification (Nehra ).
Inactivation of microorganism in meat and meat products by atmospheric pressure cold plasma with dielectric barrier discharge
| Microbes | Reduction rate (Log CFU/g) / Substrate | Discharge gas | Power / Frequency | Exposure time | Type / Distance | Reference |
|---|---|---|---|---|---|---|
| Gram-positive | ||||||
| 6.52 / ham | Nitrogen / oxygen | 2 kV / 50 kHz | 2 min | Closed / - | ||
| 4.73 / chicken breast | Nitrogen / oxygen | 2 kV / 50 kHz | 2 min | Closed / - | ||
| 2.60 / bacon | Helium / oxygen | 125 W | 90 s | Open / 3 mm | ||
| 0.59 / pork loin | Helium / oxygen | 3 kV / 30 kHz | 10 min | Open / 3 mm | ||
| 2.04 / pork butt | Nitrogen / oxygen | 100 W / 15 kHz | 10 min | Closed / - | ||
| 1.90 / beef loin | Nitrogen / oxygen | 100 W / 15 kHz | 10 min | Closed / - | ||
| 2.36 / beef jerky | Ambient air | 15 kHz | 10 min | Closed / - | ||
| 3.30 / chicken breast | Oxygen / helium | 16 kV / 30 kHz | 8 min | Open / 1 cm | ||
| Gram-negative | ||||||
| 3.00 / bacon | Helium / oxygen | 125 W | 90 s | Open / 3 mm | ||
| 0.35 / pork loin | Helium / oxygen | 3 kV / 30 kHz | 10 min | Open / 3 mm | ||
| 2.54 / pork butt | Nitrogen / oxygen | 100 W / 15 kHz | 10 min | Closed / - | ||
| 2.57 / beef loin | Nitrogen / oxygen | 100 W / 15 kHz | 10 min | Closed / - | ||
| 2.65 / beef jerky | Ambient air | 15 kHz | 10 min | Closed / - | ||
| 1.7 / bacon | Helium / oxygen | 125 W | 90 s | Open / 3 mm | ||
| 2.68 / pork butt | Nitrogen / oxygen | 100 W / 15 kHz | 10 min | Closed / - | ||
| 2.28 / beef loin | Nitrogen / oxygen | 100 W / 15 kHz | 10 min | Closed / - | ||
| 3.03 / beef jerky | Ambient air | 15 kHz | 10 min | Closed / - | ||
| 2.54 / chicken breast | Ambient air | 30 kV / 0.5 kHz | 3 min | Open / 2 mm | ||
| 2.45 / chicken breast | Ambient air | 30 kV / 0.5 kHz | 3 min | Open / 2 mm | ||
The development of new nitrite sources and the direct curing of meat products by atmospheric pressure cold plasma with dielectric barrier discharge
| Substrate | Discharge gas | Power / Frequency | Exposure time | Nitrite content | Reference |
|---|---|---|---|---|---|
| Distilled water | Ambient air | 200 W / 15 kHz | 120 min | 782 mg L−1 | |
| Red perilla extract | Ambient air | 550 W / 25 kHz | 60 min | 3.74 g kg−1 | |
| Meat batter | Ambient air | 550 W / 25 kHz | 30 min | 65.96 mg kg−1 | |
| Meat batter | Ambient air | 600 W / 25 kHz | 30 min | 42 mg kg−1 |
Fig. 2.Plasma curing system (Lee ).