Literature DB >> 28942053

Modelling with a meshfree approach the cornea-aqueous humor interaction during the air puff test.

Andrea Montanino1, Maurizio Angelillo2, Anna Pandolfi3.   

Abstract

The air puff test is an in-vivo investigative procedure commonly utilized in ophthalmology to estimate the intraocular pressure. Potentially the test, quick and painless, could be combined with inverse analysis methods to characterize the patient-specific mechanical properties of the human cornea. A rapid localized air jet applied on the anterior surface induces the inward motion of the cornea, that interacts with aqueous humor-the fluid filling the narrow space between cornea and iris-with a strong influence on the dynamics of the cornea. While models of human cornea reproduce accurately patient-specific geometries and have reached a considerable level of complexity in the description of the material, yet scant attention has been paid to the aqueous humor, and no eye models accounting for the physically correct fluid-solid interaction are currently available. The present study addresses this gap by proposing a fluid-structure interaction approach based on a simplified two-dimensional axis-symmetric geometry to simulate the anterior chamber of the eye undergoing the air puff test. We regard the cornea as a membrane described through an analytical model and discretize the fluid with a mesh-free particle approach. The membrane is assumed to be nonlinear elastic and isotropic, and the fluid weakly compressible Newtonian. Numerical analyses reveal a marked influence of the fluid on the dynamics of the cornea. We perform a parametric analysis to assess the quantitative influence of geometrical and material parameters on the mechanical response of the model. Additionally, we investigate the possibility to use the dynamics of the test to estimate the intraocular pressure.
Copyright © 2017 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Air puff test; Collocation methods; Fluid-dynamics; Fluid-solid interaction; Meshfree methods; Particle methods

Mesh:

Year:  2017        PMID: 28942053     DOI: 10.1016/j.jmbbm.2017.05.042

Source DB:  PubMed          Journal:  J Mech Behav Biomed Mater        ISSN: 1878-0180


  4 in total

1.  Estimations of Critical Clear Corneal Incisions Required for Lens Insertion in Cataract Surgery: A Mathematical Aspect.

Authors:  Nan Qi; David Lockington; Lei Wang; Kanna Ramaesh; Xiaoyu Luo
Journal:  Front Physiol       Date:  2022-04-08       Impact factor: 4.755

2.  Cornea modelling.

Authors:  Anna Pandolfi
Journal:  Eye Vis (Lond)       Date:  2020-01-07

3.  A detailed methodology to model the Non Contact Tonometry: a Fluid Structure Interaction study.

Authors:  Elena Redaelli; Jorge Grasa; Begoña Calvo; Jose Felix Rodriguez Matas; Giulia Luraghi
Journal:  Front Bioeng Biotechnol       Date:  2022-10-04

4.  Simulation of Air Puff Tonometry Test Using Arbitrary Lagrangian-Eulerian (ALE) Deforming Mesh for Corneal Material Characterisation.

Authors:  Osama Maklad; Ashkan Eliasy; Kai-Jung Chen; Vassilios Theofilis; Ahmed Elsheikh
Journal:  Int J Environ Res Public Health       Date:  2019-12-19       Impact factor: 3.390

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.