Literature DB >> 28941235

Flexible wide-field optical micro-angiography based on Fourier-domain multiplexed dual-beam swept source optical coherence tomography.

Shaozhen Song1, Jingjiang Xu1, Ruikang K Wang1,2.   

Abstract

Wide-field optical coherence tomography angiography (OCTA) is gaining interest in clinical imaging applications. In this pursuit, it is challenging to maintain the imaging resolution and sensitivity throughout the wide field of view (FoV). Here, we propose a novel method/system of dual-beam arrangement and Fourier-domain multiplexing to achieve wide-field OCTA when imaging the uneven surface samples. The proposed system provides 2 separate FoVs, with flexibility that the imaging area, focus of the imaging beam and imaging depth range can be individually adjusted for each FoV, leading to either (1) increased system imaging FoV or (2) capability of targeting 2 regions of interests that locate at depths with large difference between each other. We demonstrate this novel method by employing 100 kHz laser source in a swept source OCTA to achieve an effective 200 kHz sweeping rate, covering a 22 × 22 mm FoV. The results are verified by a SS-OCTA system employing a 200 kHz laser source, together with the experimental demonstrations when imaging whole brain vasculature in rodent models and skin blood perfusion in human fingers, show-casing the capability of proposed system to image live large samples with complex surface topography.
© 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

Entities:  

Keywords:  3-dimensional image acquisition; imaging systems; medical and biological imaging; multiplexing; optical coherence tomography

Mesh:

Year:  2017        PMID: 28941235      PMCID: PMC5839934          DOI: 10.1002/jbio.201700203

Source DB:  PubMed          Journal:  J Biophotonics        ISSN: 1864-063X            Impact factor:   3.207


  39 in total

1.  Extended focus depth for Fourier domain optical coherence microscopy.

Authors:  R A Leitgeb; M Villiger; A H Bachmann; L Steinmann; T Lasser
Journal:  Opt Lett       Date:  2006-08-15       Impact factor: 3.776

2.  Megahertz OCT for ultrawide-field retinal imaging with a 1050 nm Fourier domain mode-locked laser.

Authors:  Thomas Klein; Wolfgang Wieser; Christoph M Eigenwillig; Benjamin R Biedermann; Robert Huber
Journal:  Opt Express       Date:  2011-02-14       Impact factor: 3.894

3.  Compensation of spectral and RF errors in swept-source OCT for high extinction complex demodulation.

Authors:  Meena Siddiqui; Serhat Tozburun; Ellen Ziyi Zhang; Benjamin J Vakoc
Journal:  Opt Express       Date:  2015-03-09       Impact factor: 3.894

4.  Long-range and wide field of view optical coherence tomography for in vivo 3D imaging of large volume object based on akinetic programmable swept source.

Authors:  Shaozhen Song; Jingjiang Xu; Ruikang K Wang
Journal:  Biomed Opt Express       Date:  2016-10-27       Impact factor: 3.732

5.  Akinetic all-semiconductor programmable swept-source at 1550 nm and 1310 nm with centimeters coherence length.

Authors:  M Bonesi; M P Minneman; J Ensher; B Zabihian; H Sattmann; P Boschert; E Hoover; R A Leitgeb; M Crawford; W Drexler
Journal:  Opt Express       Date:  2014-02-10       Impact factor: 3.894

6.  Robust numerical phase stabilization for long-range swept-source optical coherence tomography.

Authors:  Shaozhen Song; Jingjiang Xu; Shaojie Men; Tueng T Shen; Ruikang K Wang
Journal:  J Biophotonics       Date:  2017-05-09       Impact factor: 3.207

7.  Impaired Collateral Flow Compensation During Chronic Cerebral Hypoperfusion in the Type 2 Diabetic Mice.

Authors:  Yasuo Nishijima; Yosuke Akamatsu; Shih Yen Yang; Chih Cheng Lee; Utku Baran; Shaozhen Song; Ruikang K Wang; Teiji Tominaga; Jialing Liu
Journal:  Stroke       Date:  2016-11-10       Impact factor: 7.914

8.  Visualization of real-time intraoperative maneuvers with a microscope-mounted spectral domain optical coherence tomography system.

Authors:  Justis P Ehlers; Yuankai K Tao; Sina Farsiu; Ramiro Maldonado; Joseph A Izatt; Cynthia A Toth
Journal:  Retina       Date:  2013-01       Impact factor: 4.256

9.  Acoustic micro-tapping for non-contact 4D imaging of tissue elasticity.

Authors:  Łukasz Ambroziński; Shaozhen Song; Soon Joon Yoon; Ivan Pelivanov; David Li; Liang Gao; Tueng T Shen; Ruikang K Wang; Matthew O'Donnell
Journal:  Sci Rep       Date:  2016-12-23       Impact factor: 4.379

10.  Ultrahigh speed endoscopic optical coherence tomography using micromotor imaging catheter and VCSEL technology.

Authors:  Tsung-Han Tsai; Benjamin Potsaid; Yuankai K Tao; Vijaysekhar Jayaraman; James Jiang; Peter J S Heim; Martin F Kraus; Chao Zhou; Joachim Hornegger; Hiroshi Mashimo; Alex E Cable; James G Fujimoto
Journal:  Biomed Opt Express       Date:  2013-06-14       Impact factor: 3.732

View more
  2 in total

Review 1.  Optical coherence elastography in ophthalmology.

Authors:  Mitchell A Kirby; Ivan Pelivanov; Shaozhen Song; Łukasz Ambrozinski; Soon Joon Yoon; Liang Gao; David Li; Tueng T Shen; Ruikang K Wang; Matthew O'Donnell
Journal:  J Biomed Opt       Date:  2017-12       Impact factor: 3.170

2.  Visualization of skin microvascular dysfunction of type 1 diabetic mice using in vivo skin optical clearing method.

Authors:  Wei Feng; Rui Shi; Chao Zhang; Shaojun Liu; Tingting Yu; Dan Zhu
Journal:  J Biomed Opt       Date:  2018-08       Impact factor: 3.170

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.