Literature DB >> 28940444

Accurate representation of interference colours (Michel-Lévy chart): from rendering to image colour correction.

S A Linge Johnsen1, J Bollmann1, H W Lee2, Y Zhou2.   

Abstract

Here a work flow towards an accurate representation of interference colours (Michel-Lévy chart) digitally captured on a polarised light microscope using dry and oil immersion objectives is presented. The work flow includes accurate rendering of interference colours considering the colour temperature of the light source of the microscope and chromatic adaptation to white points of RGB colour spaces as well as the colour correction of the camera using readily available colour targets. The quality of different colour correction profiles was tested independently on an IT8.7/1 target. The best performing profile was using the XYZ cLUT algorithm and it revealed a ΔE00 of 1.9 (6.4 no profile) at 5× and 1.1 (8.4 no profile) at 100× magnification, respectively. The overall performance of the workflow was tested by comparing rendered interference colours with colour-corrected images of a quartz wedge captured over a retardation range from 80-2500 nm at 5× magnification. Uncorrected images of the quartz wedge in sRGB colour space revealed a mean ΔE00 of 12.3, which could be reduced to a mean of 4.9 by applying a camera correction profile based on an IT8.7/1 target and the Matrix only algorithm (ΔE00 < 1.0 signifies colour differences imperceptible by the human eye). ΔE00 varied significantly over the retardation range of 80-2500 nm of the quartz wedge, but the reasons for this variation is not well understood and the quality of colour correction might be further improved in future by using custom made colour targets specifically designed for the analysis of high-order interference colours.
© 2017 The Authors Journal of Microscopy © 2017 Royal Microscopical Society.

Entities:  

Keywords:  Colour correction; Michel-Lévy chart; digital imaging; interference colours; polarised light microscopy

Year:  2017        PMID: 28940444     DOI: 10.1111/jmi.12641

Source DB:  PubMed          Journal:  J Microsc        ISSN: 0022-2720            Impact factor:   1.758


  2 in total

1.  Miniaturized flow cell with pneumatically-actuated vertical nanoconfinement for single-molecule imaging and manipulation.

Authors:  Daniel J Berard; Sabrina R Leslie
Journal:  Biomicrofluidics       Date:  2018-09-28       Impact factor: 2.800

2.  Coccolith mass and morphology of different Emiliania huxleyi morphotypes: A critical examination using Canary Islands material.

Authors:  Simen Alexander Linge Johnsen; Jörg Bollmann
Journal:  PLoS One       Date:  2020-03-27       Impact factor: 3.240

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.