Literature DB >> 28938032

Efficacy of Sealing Agents on Preload Maintenance of Screw-Retained Implant-Supported Prostheses.

Camila Berbel Seloto, Henrico Badaoui Strazzi Sahyon, Paulo Henrique Dos Santos, Juliana Aparecida Delben, Wirley Gonçalves Assunção.   

Abstract

PURPOSE: The aim of this study was to evaluate the effect of sealing agents on preload maintenance of screw joints.
MATERIALS AND METHODS: A total of four groups (n = 10 in each group) of abutment/implant systems, including external hexagon implants and antirotational UCLA abutments with a metallic collar in cobalt-chromium alloy, were assessed. In the control group (CG), no sealing agent was used at the abutment screw/implant interface. In the other groups, three different sealing agents were used at the abutment screw/implant interface: anaerobic sealing agent for medium torque (ASMT), anaerobic sealing agent for high torque (ASHT), and cyanoacrylate-based bonding agent (CYAB). All abutments were attached to the implants at 32 ± 1 N.cm. After 48 ± 2 hours of initial tightening, loosing torque (detorque) was measured using a digital torque wrench. Data were analyzed using Shapiro-Wilk, Wilcoxon, and Kruskal-Wallis tests, at 5% level of significance.
RESULTS: In the CG and ASMT groups, detorque was lower than the insertion torque (24.6 ± 1.5 N.cm and 24.3 ± 1.1 N.cm, respectively). In the ASHT and CYAB groups, mean detorque increased in comparison to the insertion torque (51.0 ± 7.4 N.cm and 47.7 ± 15.1 N.cm, respectively).
CONCLUSION: The ASHT was more efficient than the other sealing agents, increasing the remaining preload (detorque value) 58.88%. Although the cyanoacrylate-based bonding agent also generated high detorque values, the high standard deviation suggested its lower reliability.

Entities:  

Mesh:

Substances:

Year:  2017        PMID: 28938032     DOI: 10.11607/jomi.5576

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  1 in total

1.  Sealing agent reduces formation of single and dual-species biofilms of Candida albicans and Enterococcus faecalis on screw joints at the abutment/implant interface.

Authors:  Cecília Alves de Sousa; Jadison Junio Conforte; Karina Sampaio Caiaffa; Cristiane Duque; Wirley Gonçalves Assunção
Journal:  PLoS One       Date:  2019-10-22       Impact factor: 3.240

  1 in total