Literature DB >> 28937526

COMPARISON OF CORNEAL WETTING PROPERTIES OF DIFFERENT DISPERSIVE OPHTHALMIC VISCOSURGICAL DEVICES: An Optical Coherence Tomography Study.

Cagatay Karaca1, Mustafa Ozkose2, Metin Unlu1, Duygu Gulmez Sevim1, Ertugrul Mirza1.   

Abstract

PURPOSE: To compare corneal wetting performances of different dispersive ophthalmic viscosurgical devices.
METHODS: Three different types of dispersive ophthalmic viscosurgical devices, hydroxypropyl methylcellulose %2 (HPMC), sodium hyaluronate %3-sodium chondroitin sulphate %4 (HACS), and sodium hyaluronate %3 (HA), were applied on corneal surfaces of 10 healthy volunteer subjects repeatedly at 3 different time points. Corneal wetting properties of the ophthalmic viscosurgical devices were compared qualitatively and quantitatively by anterior segment optical coherence tomography for 30 minutes.
RESULTS: Sodium hyaluronate 3% and HACS applications had a higher mean precorneal ophthalmic viscosurgical device thickness than HPMC application at all time points (seventh minute HPMC: 105.2 ± 25.3 μm, HA: 561.4 ± 115.8 μm, HACS: 481.2 ± 55 μm, P < 0.001). All HPMC applications were terminated by the 12th minute because of insufficient corneal wetting. Mean survival estimate time was significantly shortest for HPMC (11.5 ± 0.5 minutes, P < 0.001) and longest for HA (29.7 ± 0.28 minutes). It was slightly shorter for HACS (26.9 ± 0.87 minutes, P = 0.007) than the HA application.
CONCLUSION: Sodium hyaluronate 3% and HACS provide superior corneal covering compared with HPMC with an effect that can be maintained up to 30 minutes. They may be an effective option for corneal wetting during long vitreoretinal surgeries with longer duration of effect and fever number of applications.

Entities:  

Mesh:

Substances:

Year:  2018        PMID: 28937526     DOI: 10.1097/IAE.0000000000001854

Source DB:  PubMed          Journal:  Retina        ISSN: 0275-004X            Impact factor:   4.256


  2 in total

1.  Addition Of D-Sorbitol Improves The Usability Of Ophthalmic Viscosurgical Devices.

Authors:  Ippei Watanabe; Mayumi Nagata; Hiroyuki Matsushima
Journal:  Clin Ophthalmol       Date:  2019-09-23

2.  Quantitative Assessment of Ophthalmic Viscosurgical Devices on Visibility, Spreadability, and Durability as Corneal Wetting Agents for the Wet Shell Technique.

Authors:  Ippei Watanabe; Hirotaka Hoshi; Kiyoshi Suzuki; Mayumi Nagata; Hiroyuki Matsushima
Journal:  Ophthalmol Ther       Date:  2020-07-01
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.