| Literature DB >> 28935985 |
Yaseera Ismail1, Stuti Joshi2, Francesco Petruccione2,3.
Abstract
The generation of two photon fields, to date, has been demonstrated utilizing a fully coherent pump beam. In this paper we demonstrate, the theoretical and experimental generation of polarization entangled single photon pairs by varying the spatial coherence of the pump beam. The effect of the pump beam spatial coherence on the visibility of a polarization-entangled single photon source is investigated. A comparison of the visibility measurements using a fully coherent and partially coherent pump beam is performed. It is shown that the partial coherence of the pump beam contributes to an increase in the visibility. The coherence properties of the beam are significant for free-space optical transmission in particular for long range free-space quantum communication.Entities:
Year: 2017 PMID: 28935985 PMCID: PMC5608753 DOI: 10.1038/s41598-017-12376-6
Source DB: PubMed Journal: Sci Rep ISSN: 2045-2322 Impact factor: 4.379
Figure 1Schematic setup used to study the influence of the pump spatial coherence on the polarization entangled photons.
Figure 2Schematic of an entangled photon source comprising of a pump laser lasing as 405 nm, diffuser system containing a ground glass diffuser and lens system, mirrors (M), a Half Wave Plate (HWP), a Quartz Crystal (QC), BBO crystal, a polarizer in each arm followed by infra-red filters (IF) and a fiber coupler connected to single photon detectors (SPCM1 and SPCM2) via polarization maintaining fibers to the in-house coincidence counting unit (CCU) comprising of a Field Programmable Gated Array (FPGA).
Figure 3Correlation fringes for the rectilinear (α = 0°) and diagonal basis (α = 45°) while varying the orientation of the second polarizer (β :0° to 360°) for the pump beam coherence length of 112 μm.
Visibility obtained from the correlation fringes for the rectilinear (α = 0°) and diagonal basis (α = 45°) for a FSC beam and varying coherence length of the PSC beam.
| Pump Beam Size | Pump Beam Coherent Length | Rectilinear Basis | Diagonal Basis | Theoretical Visibility |
|---|---|---|---|---|
| — | FSC | 90.1 ± 1.3 % | 90.6 ± 1.3 % | 97% |
| 110 | 112 | 95.1 ± 3.4 % | 94.7 ± 3.9 % | 98.5% |
| 350.5 | 35 | 95.8 ± 2.9 % | 95.6 ± 3.1 % | 98.7% |
| 456.8 | 27 | 96.9 ± 3.1 % | 97.1 ± 2.8 % | 98.9% |
Measured violation of the CHSH inequality for the fully (FSC) and varying values of coherence length of the partially spatially coherent (PSC) pump beam.
| Pump Beam Coherent Length | CHSH Inequality | Percentage(%) |
|---|---|---|
| FSC | 2.70 | 2.0 |
| 112 | 2.76 | 0.2 |
| 35 | 2.77 | 0.2 |
| 27 | 2.78 | 0.2 |