Literature DB >> 28932142

Color stability and marginal integrity of interim crowns: An in vitro study.

Marwa I Elagra1, Mohammad R Rayyan1, Maisam M Alhomaidhi1, Areej A Alanaziy2, Mona O Alnefaie2.   

Abstract

OBJECTIVE: Many commercial dental materials are used to fabricate interim restorations. This study aimed to compare the color stability and the marginal integrity of four different interim crown materials.
MATERIALS AND METHODS: An ivorine right maxillary central incisor was prepared for a full coverage all-ceramic restoration. A total of 36 specimens in the form of crowns were fabricated on the master die using four different materials (n = 9); Polymethyl methacrylate (PMMA) resin (TrimPLUS), PMMA computer-aided design, and computer-aided manufacturing (CAD-CAM) blocks (Ceramill TEMP), cold cure bis-acryl resin (Success CD), and bis-acryl resin dual-cure composite (TempSpan). Color change ΔE for each sample was calculated by measuring its color as Commission Internationale de l'Eclairage L* a* b* with a spectrophotometer before and after immersing in a concentrated tea solution for 7 days. Marginal gap was measured at four reference points using stereomicroscope at ×40. One-way ANOVA and the Tukey multiple comparisons test were used to determine any statistically significant difference between the four groups, (α = 0.05).
RESULTS: Success CD showed significantly the greatest color change (7.7) among all the tested materials, while no significant difference was found between the other three materials. TempSpan showed significantly the highest marginal gap formation (430.15 μm), while no significant difference was found between the three other materials.
CONCLUSIONS: Bis-acryl resin composite materials demonstrated clinically noticeable change in color while PMMA materials demonstrated superior color stability. Dual cure interim materials exhibited significantly higher marginal discrepancy in comparison to PMMA and cold cure bis-acrylic resin materials. CAD-CAM PMMA material exhibited the best color stability and marginal integrity.

Entities:  

Keywords:  Color stability; interim restorations; marginal fit

Year:  2017        PMID: 28932142      PMCID: PMC5594961          DOI: 10.4103/ejd.ejd_66_17

Source DB:  PubMed          Journal:  Eur J Dent


INTRODUCTION

Interim restorations play an important role in the success of dental treatment. They are essential to provide protection for dentin, restore esthetic and function, maintain positional stability, and promote gingival health. Although interim restorations are used for limited period, they still have to meet certain biologic, mechanical, and esthetic requirements to achieve these functions.[1] Polymethyl methacrylate (PMMA) has been long in use for the fabrication of interim restorations. Although this material has provided satisfactory interim restorations in regard to esthetics and function, it has been accompanied with drawbacks such as heat generation, shrinkage, excess monomer, and color changes.[2] In the past few decades, several other materials have come into usage. These include ethylmethacrylate, vinylmethacrylate, and butylmethacrylate, bis-acrylics (bisphenol A-glycidyl methacrylate and urethane dimethacrylate).[3] Recently, computer-aided design and computer-aided manufacturing (CAD-CAM) technology have been utilized to fabricate interim restorations. Crosslinked PMMA blocks which have been previously polymerized are milled to produce interim restorations of better strength as well as homogeneity. Unlike conventional PMMA materials, PMMA blocks do not undergo polymerization shrinkage or have excess monomer as they are fully polymerized before milling. Moreover, studies have suggested superior physical and mechanical properties of this material and promoted its use for long-term interim restorations.[45] Materials used for the fabrication of interim restorations varies greatly in their physical and mechanical properties such as stains resistance, dimensional stability, polishability, strength, surface hardness, and biocomaptability.[678910] Yet no material is superior in all aspects and the restorative dentist should make the assessment of these materials’ advantages and disadvantages to decide which to use.[11] The current study aimed to compare four different materials used to fabricate interim restorations in terms of their marginal integrity and color stability.

MATERIALS AND METHODS

The study was registered and approved by the Institutional Review Board of Riyadh Colleges of Dentistry and Pharmacy (FUGRP/2012/5).

Preparation of samples

An ivorine right maxillary incisor was prepared for a full coverage all-ceramic restoration with a heavy chamfer margin. Four points were engraved at a distance of 1 mm below the facial, lingual, mesial, and distal margins[12] [Figure 1].
Figure 1

Master die

Master die A total of 36 specimens in the form of crowns were fabricated on the master die using four different interim materials. The samples were divided according to the material used into four groups of nine specimens in each group (n = 9) [Table 1].
Table 1

Interim crown materials under investigation

Interim crown materials under investigation For each interim crown in group PM, BC, and DC, the material was mixed and cured according to its manufacturer instructions. For group PMCAD, an impression for the master die was made and the working die was scanned. Crowns were designed and milled using Ceramill Mind software and Ceramill Motion Milling Machine (Amann Girrbach, Austria). Specimens of all groups were then finished and polished according to manufacturers’ instructions. All specimens were then stored in a light-protected container until ready for testing.

Testing

Marginal adaptation

Crowns were fitted on the master die and tested for marginal adaptation using stereomicroscope at ×40 magnification (Nikon Stereoscopic Microscope, SMZ1000), and photographed (Nikon Digital Camera, DXM1200F). At each of the four engraved reference points, the vertical marginal gap between the finish line and the crown margin was measured to the nearest 0.01 μm [Figure 2]. The average marginal gap was calculated and tabulated for each sample.
Figure 2

Vertical marginal gap at the labial reference point of one of the samples

Vertical marginal gap at the labial reference point of one of the samples

Color stability test

Baseline color measurements Baseline color measurements for all specimens were done using spectrophotometer (Color-Eye 7000A, X-Rite Europe GmbH, Switzerland). The measurements were established in mathematic coordinates referred to the international color space Commission Internationale de l’Eclairage L* a* b*. For each sample, three readings at the labial surface were taken. The average L*, a*, and b* values for the three readings were calculated and tabulated as the baseline color measurements. Staining solution Specimens were immersed in a high concentration tea solution (Lipton, Unilever Gulf FZE, UAE) at 37°C. Temperature was controlled using a thermostatically controlled incubator. The solution was constantly changed every 2 days. After 7 days of immersing crowns in the tea solution, the specimens were rinsed with distilled water, brushed with Aquafresh, soft brush (GlaxoSmithKline, the UK), and blotted dry with tissue paper before the second color measurement. Poststain color measurements The color of the specimens was measured again using the spectrophotometer and tabulated as described previously. The calculation of the color change Δ E* between the two color positions (after storage and baseline) was calculated according to the following formula: ΔE = ([L2* − L1*]2 + [a2* − a1*]2 + [b2* − b1*]2)1/2.[13] Color change >3.3 was considered clinically unacceptable.[14]

Statistical analysis

The measurements were analyzed using one-way ANOVA with a Tukey post hoc multiple comparison to determine any statistically significant difference in color change and marginal gap between the four materials. Analysis was done using the Statistical Package for Social Sciences (SPSS version 17.0 SPSS Inc, Chicago, USA). The level of statistical significance was set at P < 0.05.

RESULTS

Color stability

The mean color change Δ E values of the four materials are shown in Figure 3. TempSpan and Success CD are the only two materials that exhibited clinically noticeable color change (ΔE >3.3). Analysis of results showed significant difference between the four materials (P = 0.00). Success CD showed significantly the greatest color change among all the tested materials, while no significant difference was found between the other three materials [Table 2].
Figure 3

Mean color change ΔE

Table 2

One-way ANOVA comparison for the color change between groups

Mean color change ΔE One-way ANOVA comparison for the color change between groups

Marginal adaptation

The mean gap formation for each group is shown in Figure 4. Analysis of results showed significant difference between the four materials (P = 0.00). TempSpan showed significantly the highest marginal gap formation among the tested materials, while no significant difference was found between the three other materials [Table 3].
Figure 4

Mean marginal gap in μm

Table 3

One-way ANOVA comparison for marginal gap between groups

Mean marginal gap in μm One-way ANOVA comparison for marginal gap between groups

DISCUSSION

Despite being used for limited time, color stability of interim crowns is a concern, particularly when the interim restoration is in the esthetic zone, and must be worn for extended periods of time. Moreover, an interim restoration needs to seal and insulate the prepared tooth from the oral environment, thereby protecting the underlying pulp from insult and injury and the prepared dentin from recurrent decay. Yet, many studies have reported significant color changes and marginal discrepancy of interim restorations made of different materials.[589] Unlike permanent restorations, interim restorations are usually used for limited times. Thus, in the current study, samples were immersed in high concentration tea solution for 1 week. This method does not exactly reflect the clinical reality. However, similar protocol to evaluate color stability of interim restorations was adopted in previous studies and was considered adequate.[9] Various studies have reported different thresholds of color difference values ranged from 1 to 3.7 above which the color change is perceptible by the human eye.[14] In the present study, a color change (ΔE*) >3.3 was considered visually perceptible as well as clinically unacceptable. Both bis-acryl methacrylate based resins in this study; TempSpan and Success CD demonstrated visually perceptible and clinically unacceptable color change (3.88 and 7.74, respectively). Moreover, the auto-cured bis-acryl (Success CD) crowns showed significantly the highest color change. Those results were in agreement with previous studies.[8910] Proprietary variations in chemistry, such as size distribution of the PMMA particles, polarity of the monomers, pigment stability, and efficiency of the initiator system for interim resins may lead to differing degrees of polymerization, water sorption, and consequently, color stability.[8] As with permanent restorations, marginal adaptation of interim restorations is detrimental for the success of treatment and maintenance of teeth and gingival health.[1] The results of the present studies showed that dual cured bis-acryl interim material (TempSpan) demonstrated significantly the highest mean marginal gap (430.15 μm) when compared to the other groups. This was in agreement with Givens et al. who suggested that that the majority of gap formation occurs during the auto-cure phase of polymerization of dual-cured materials.[9] In this study, the machined CAD-CAM material demonstrated the lowest mean color change (1.84) and lowest mean marginal gap (49.76 μm). This can be attributed to the industrially optimized conditions under which the polymerization of this material happens so it has no or minimal residual unreacted monomers and lower polymerization shrinkage. This supports the recommendation of similar studies to use machined CAD-CAM resin blocks for the fabrication of long-term interim restorations.[45]

CONCLUSIONS

Under the conditions of this study, the following can be concluded: The bis-acryl resin composite materials demonstrated clinically noticeable change in color while PMMA materials demonstrated superior color stability Dual cure interim materials exhibited significantly higher marginal discrepancy in comparison to PMMA and cold cure bis-acrylic resin materials CAD-CAM PMMA material exhibited the best color stability and marginal integrity.

Financial support and sponsorship

Nil.

Conflicts of interest

There are no conflicts of interest.
  13 in total

Review 1.  A review of selected dental literature on contemporary provisional fixed prosthodontic treatment: report of the Committee on Research in Fixed Prosthodontics of the Academy of Fixed Prosthodontics.

Authors:  David R Burns; David A Beck; Steven K Nelson
Journal:  J Prosthet Dent       Date:  2003-11       Impact factor: 3.426

2.  Color stability of provisional crown and fixed partial denture resins.

Authors:  Debra R Haselton; Ana M Diaz-Arnold; Deborah V Dawson
Journal:  J Prosthet Dent       Date:  2005-01       Impact factor: 3.426

3.  Marginal accuracy of interim restorations fabricated from four interim autopolymerizing resins.

Authors:  Farahnaz Nejatidanesh; Hamid Reza Lotfi; Omid Savabi
Journal:  J Prosthet Dent       Date:  2006-05       Impact factor: 3.426

4.  Color stability evaluation of aesthetic restorative materials.

Authors:  Adriana Postiglione Bührer Samra; Stella Kossatz Pereira; Leyla Cotrina Delgado; Christiane Phillipini Borges
Journal:  Braz Oral Res       Date:  2008 Jul-Sep

5.  Color stability of provisional resin restorative materials.

Authors:  S A Yannikakis; A J Zissis; G L Polyzois; C Caroni
Journal:  J Prosthet Dent       Date:  1998-11       Impact factor: 3.426

6.  Comparison of interim restorations fabricated by CAD/CAM with those fabricated manually.

Authors:  Mohammad M Rayyan; Moustafa Aboushelib; Nagwa M Sayed; Ahmed Ibrahim; Ryo Jimbo
Journal:  J Prosthet Dent       Date:  2015-05-20       Impact factor: 3.426

Review 7.  Provisional materials: advances lead to extensive options for clinicians.

Authors:  John C Comisi
Journal:  Compend Contin Educ Dent       Date:  2015-01

8.  Comparative in vitro evaluation of two provisional restorative materials.

Authors:  H M Young; C T Smith; D Morton
Journal:  J Prosthet Dent       Date:  2001-02       Impact factor: 3.426

9.  Comparative assessment of marginal accuracy of grade II titanium and Ni-Cr alloy before and after ceramic firing: An in vitro study.

Authors:  Abhijit Patil; Kishan Singh; Sukant Sahoo; Suraj Suvarna; Prince Kumar; Anupam Singh
Journal:  Eur J Dent       Date:  2013-07

10.  Discoloration of different esthetic restorative materials: A spectrophotometric evaluation.

Authors:  Matteo Ceci; Matteo Viola; Davide Rattalino; Riccardo Beltrami; Marco Colombo; Claudio Poggio
Journal:  Eur J Dent       Date:  2017 Apr-Jun
View more
  4 in total

1.  Retrospective clinical and radiographic evaluation of restored endodontically treated teeth.

Authors:  Paula Pontes Garcia; Aline Cappoani; Ricardo Susin Schelbauer; Gisele Maria Correr; Carla Castiglia Gonzaga
Journal:  Restor Dent Endod       Date:  2020-10-07

2.  Assessment of Marginal Integrity and Color Stability of Provisional Restoration Fabricated from Different Autopolymerizing Acrylic Resins - A Comparative Study.

Authors:  Mohamed Usman Jafar Abdulla; Mohammed Hussain Dafer Al Wadei; Mohamed Abd-Ellatif El-Patal; George Sam; Yousef H Abokhlifa; Ashutosh Thorat
Journal:  J Pharm Bioallied Sci       Date:  2021-06-05

3.  Influence of experimental staining on the color stability of indirect computer-aided design/computer-aided manufacturing dental provisional materials.

Authors:  Thamer Almohareb; Mohammed S Alkatheeri; Fahim Vohra; Ali Alrahlah
Journal:  Eur J Dent       Date:  2018 Apr-Jun

4.  Influences of Toothbrushing and Different Toothpastes on the Surface Roughness and Color Stability of Interim Prosthodontic Materials.

Authors:  Ayşegül Köroğlu; Onur Şahin; Ahmet Serkan Küçükekenci; Doğu Ömür Dede; Hüsniye Yıldırım; Burak Yilmaz
Journal:  Materials (Basel)       Date:  2022-08-24       Impact factor: 3.748

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.