| Literature DB >> 28932006 |
Tadamitsu Matsuda1, Takayuki Koyama2, Yasushi Kurihara1, Miki Tagami1, Yasuaki Kusumoto3, Osamu Nitta4.
Abstract
[Purpose] This study investigated lumbar muscle fatigue before and after maintaining a seated position for one hour, lumbar and pelvic inclination angle change, in subjects with and without active lumber support.Entities:
Keywords: Active lumbar support; Low back pain; Muscle fatigue
Year: 2017 PMID: 28932006 PMCID: PMC5599839 DOI: 10.1589/jpts.29.1649
Source DB: PubMed Journal: J Phys Ther Sci ISSN: 0915-5287
Demographic characteristics of study subjects
| ALS activated | ALS not activated | |
|---|---|---|
| Age (years) | 21.4 ± 0.8 | 21.4 ± 0.8 |
| Height (cm) | 167.1 ± 5.6 | 169.5 ± 10.9 |
| Weight (kg) | 54.7 ± 8.5 | 57.6 ± 9.9 |
All results are reported as mean ± standard deviation.
Fig. 1.Front and side views of the developed chair with active lumbar support. Right figure: Experiment environment
Fig. 2.Schematic diagrams showing active back rest, with each cycle requiring 34 sec. a: off phase: flow of air away from the subject through the back rest (pelvic neutral position) b: stage 1: flow of air towards the subject through the back rest (pelvic forward tilt and lumber lordosis) c: stage 2: flow of air towards the subject through the back rest (more pelvic forward tilt and lumber lordosis) The air bag inserted in the lumbar support on the back expands in two stages (upper row), pushing the waist forward within one cycle (34 seconds). The lower row shows the timing of inflation of the air bag using an electric motor (DC 12.8 V, 1.8 A).
Muscle frequencies before and after maintaining normal and dynamic sitting positions for 1 hour
| ALS not activated | ALS activated | ||||
|---|---|---|---|---|---|
| pre | post | pre | post | ||
| MDF | Rt | 81.0 ± 14.2 | 65.6 ± 19.7 | 77.3 ± 17.8 | 91.6 ± 19.7 |
| Lt | 78.5 ± 10.3 | 65.9 ± 16.6* | 79.4 ± 18.0 | 89.6 ± 23.1 | |
| MPF | Rt | 101.1 ± 16.2 | 96.4 ± 17.2 | 102.7 ± 21.4 | 112.7 ± 23.0 |
| Lt | 92.4 ± 11.1 | 92.5 ± 17.8 | 101.6 ± 19.3 | 110.66 ± 21.9 | |
All reports are reported as mean ± standard deviation. *p<0.05. Rt: right; Lt: left
Parameters measured before and after maintaining ALS activated and ALS not activated for 1 hour
| ALS not activated | ALS activated | |||
|---|---|---|---|---|
| pre | post | pre | post | |
| FFD (cm) | 0 | 0.4 ± 1.1 | 3.4 ± 4.7 | 2.6 ± 5.5 |
| ROM[Rt] (°) | 30.0 ± 9.6 | 27.1 ± 8.1 | 27.9 ± 4.9 | 27.9 ± 6.4 |
| ROM[Lt] (°) | 29.3 ± 9.3 | 24.3 ± 6.7* | 27.1 ± 4.9 | 27.9 ± 5.7 |
| Stiffness (Rt) | 47.9 ± 8.4 | 54.5 ± 10.9* | 53.4 ± 9.7 | 54.8 ± 11.6 |
| Stiffness (Lt) | 50.9 ± 10.0 | 61.5 ± 8.3* | 53.0 ± 10.7 | 52.9 ± 12.5 |
| VAS | 2.5 ± 2.0 | 1.3 ± 0.9 | ||
All results are reported as mean ± standard deviation. *p<0.05. Rt: right; Lt: left