Comparison of stored red blood cell washing techniques for priming extracorporeal circuits.

Jun Sasaki1,2, Christopher Tirotta1, Hyunsoo Lim1, Kathleen Kubes1, Jane Salvaggio1, Robert Hannan1, Redmond Burke1, Jorge Ojito1.   

Abstract

BACKGROUND: The aim of this study was to compare three different blood washing techniques and describe the differences for the composition of the washed red blood cells (RBC).
METHODS: Stored RBCs less than 5 days old were washed using three different techniques. 1) Washing with normal saline with the COBE Model 2991 blood processor in the blood bank (BB-S). 2) Washing with normal saline with the Continuous AutoTransfusion System (C.A.T.S) in the operating room (OR-S). 3) Washing with Plasma-Lyte with the C.A.T.S in the operating room (OR-PL). Then, we compared the values for hemoglobin (Hb), hematocrit (Hct), blood volume, RBC volume, lactate, glucose, sodium and potassium of the three different groups.
RESULTS: Forty-five units of RBCs were washed and analyzed (15 for each technique). The OR-S RBCs, when compared to the BB-S RBCs, had lower hemoglobin (g/dL) (22.8 vs 24.1, p=0.006), lower hematocrit (%) (67 vs 71, p=0.006), higher RBC volume (ml) (161 vs 130, p<0.001), higher glucose (mg/dL) (185 vs 46, p<0.001) and lower sodium (mmol/L) (153 vs 158, p<0.001). When compared to the OR-S RBCs, the OR-PL RBCs showed higher potassium (mmol/L) (5.3 vs 2, p<0.001) and lower sodium (mmol/L) (129 vs 153, p<0.001).
CONCLUSION: RBCs washed with an autotransfusion device had a higher RBC volume and more physiological levels of glucose and sodium when compared with the blood processor in the blood bank. It can be an alternative option to use RBCs washed with an autotransfusion device for priming the extracorporeal circuits utilized in patients undergoing cardiac surgery.

Entities:  

Keywords:  blood washing technique; cardiac surgery; extracorporeal circuit; pediatric perfusion; stored red blood cell

Mesh:

Year:  2017        PMID: 28925857     DOI: 10.1177/0267659117730134

Source DB:  PubMed          Journal:  Perfusion        ISSN: 0267-6591            Impact factor:   1.972


  4 in total

1.  Irradiated red blood cells: Can all sins be washed away?

Authors:  Pranava Sinha; Mark Nuszkowski; Morgan Burke; Nikki Gillum Posnack
Journal:  Transfusion       Date:  2022-01       Impact factor: 3.337

2.  Bedside Allogeneic Erythrocyte Washing with a Cell Saver to Remove Cytokines, Chemokines, and Cell-derived Microvesicles.

Authors:  Ian J Welsby; Philip J Norris; William J Mauermann; Mihai V Podgoreanu; Chelsea M Conn; Laurie Meade; Tamara Cannon; Sheila M Keating; Christopher C Silliman; Marguerite Kehler; Phillip J Schulte; Daryl J Kor
Journal:  Anesthesiology       Date:  2021-03-01       Impact factor: 7.892

Review 3.  American Society of ExtraCorporeal Technology: Development of Standards and Guidelines for Pediatric and Congenital Perfusion Practice (2019).

Authors:  Molly E Oldeen; Ronald E Angona; Ashley Hodge; Tom Klein
Journal:  J Extra Corpor Technol       Date:  2020-12

4.  Effect of washing units of canine red blood cells on storage lesions.

Authors:  Ashley C Coll; Matthew K Ross; Matthew L Williams; Robert W Wills; Andrew J Mackin; John M Thomason
Journal:  J Vet Intern Med       Date:  2021-12-23       Impact factor: 3.333