Oscar M Cañete1,2, Suzanne C Purdy1,2, Michel Neeff3, Colin R S Brown3, Peter R Thorne4,2. 1. a Speech Science, School of Psychology , The University of Auckland , New Zealand. 2. d Eisdell Moore Centre for Research in Hearing and Balance , Auckland , New Zealand. 3. b Starship Children's Hospital , Auckland , New Zealand. 4. c Section of Audiology , The University of Auckland , New Zealand.
Abstract
OBJECTIVES: To study the changes in behavioural and cortical responses over time in a child with single-sided deafness fitted with a cochlear implant (CI). METHODS: Cortical auditory evoked potentials (CAEPs) in noise (+5 dB signal-to-noise ratio) were recorded and auditory skills were assessed using tests of sound localization, spatial speech perception in noise, and self-ratings of auditory abilities (Listening inventory for education, LIFE and Speech, spatial and qualities of hearing questionnaire, SSQ parental version). Measures were obtained prior to and after a CI fitting, including one, six, and 12 months after the CI switch on. RESULTS: Spatial speech recognition improved over time. At 12 months post-CI, word recognition scores were similar to those of normal hearing children. Signal-to-noise ratios for sentences decreased (i.e. improved) over time post-CI. Sound localization markedly improved at 12 months post-CI compared to baseline. Self-perception of difficulty scores decreased over time. Parental ratings of hearing abilities improved compared to baseline for all subscales. There were changes in the P1-N1-P2 complex at 12 months post-CI, which were clearer frontally across stimuli. Further research is needed to understand the significance of such changes after CI fitting for single-sided deafness. CONCLUSION: Although the changes observed could reflect maturational changes, the clinically significant improvement in recognition of speech in noise and improved questionnaire results suggest that the CI was beneficial, consistent with the feedback from the participant.
OBJECTIVES: To study the changes in behavioural and cortical responses over time in a child with single-sided deafness fitted with a cochlear implant (CI). METHODS: Cortical auditory evoked potentials (CAEPs) in noise (+5 dB signal-to-noise ratio) were recorded and auditory skills were assessed using tests of sound localization, spatial speech perception in noise, and self-ratings of auditory abilities (Listening inventory for education, LIFE and Speech, spatial and qualities of hearing questionnaire, SSQ parental version). Measures were obtained prior to and after a CI fitting, including one, six, and 12 months after the CI switch on. RESULTS: Spatial speech recognition improved over time. At 12 months post-CI, word recognition scores were similar to those of normal hearing children. Signal-to-noise ratios for sentences decreased (i.e. improved) over time post-CI. Sound localization markedly improved at 12 months post-CI compared to baseline. Self-perception of difficulty scores decreased over time. Parental ratings of hearing abilities improved compared to baseline for all subscales. There were changes in the P1-N1-P2 complex at 12 months post-CI, which were clearer frontally across stimuli. Further research is needed to understand the significance of such changes after CI fitting for single-sided deafness. CONCLUSION: Although the changes observed could reflect maturational changes, the clinically significant improvement in recognition of speech in noise and improved questionnaire results suggest that the CI was beneficial, consistent with the feedback from the participant.
Entities:
Keywords:
Child case study; Cochlear implant; Cortical auditory evoked potential; Single-sided deafness; Unilateral hearing loss
Authors: Elsa Legris; John Galvin; Sylvie Roux; Marie Gomot; Jean-Marie Aoustin; Mathieu Marx; Shuman He; David Bakhos Journal: PLoS One Date: 2018-09-24 Impact factor: 3.240