Literature DB >> 28922511

Reliability and measurement error of digital planimetry for the measurement of chronic venous leg ulcers.

Michael C Stacey1,2, Steven A Phillips1, Forough Farrokhyar1,3, Jillian M Swaine2,4.   

Abstract

Area measurements of a chronic wound are the gold standard outcome measure to determine if a wound is on a healing or nonhealing trajectory. The use of digital planimetry can provide increased accuracy in measuring wound area however it is important to know the reliability and measurement error of these devices when used by multiple assessors. The aim of this study is to determine the within rater, between rater, and standard error of measurement of a digital planimetry device. Wound area in 42 patients was measured weekly for 12 weeks by two different raters, with each rater measuring the wound 10 times per visit. Intraclass correlation coefficients (ICC 1,k) and standard error of measurement were calculated for both within and between raters using 10 and the first three repeated measures to determine if using less measurements was as reliable. The true change in wound area was calculated by dividing stander error of measurements by mean wound areas. Within rater reliability for raters 1 and 2 were 0.995 and 0.992 for 10 measurements, and 0.996 and 0.992 for 3 measurements per time point. Between rater reliability was 0.979 for 10 measurements and 0.996 for 3 measurements per time point. The within rater standard error of measurement for raters 1 and 2 was 0.98 cm2 and 1.28 cm2 for 10 measurements and 0.895 cm2 and 1.29 cm2 for 3 measurements at each time point. The standard error of measurement for between raters was 2.07 cm2 for 10 measurements and 2.25 cm2 for 3 measurements per time point. The true change in wound size varied from 6.4% for within one rater to 15.7% for across different raters. This study found that both within and between rater reliability of the digital planimetry device was very high for three measurements per time point.
© 2017 by the Wound Healing Society.

Entities:  

Mesh:

Year:  2017        PMID: 28922511     DOI: 10.1111/wrr.12587

Source DB:  PubMed          Journal:  Wound Repair Regen        ISSN: 1067-1927            Impact factor:   3.617


  3 in total

1.  Superiority of a Novel Multifunctional Amorphous Hydrogel Containing Olea europaea Leaf Extract (EHO-85) for the Treatment of Skin Ulcers: A Randomized, Active-Controlled Clinical Trial.

Authors:  José Verdú-Soriano; Marisol de Cristino-Espinar; Silvia Luna-Morales; Caridad Dios-Guerra; Javier Caballero-Villarraso; Paloma Moreno-Moreno; Antonio Casado-Díaz; Miriam Berenguer-Pérez; Ipek Guler-Caamaño; Olga Laosa-Zafra; Leocadio Rodríguez-Mañas; José Luis Lázaro-Martínez
Journal:  J Clin Med       Date:  2022-02-25       Impact factor: 4.241

2.  SfM-3DULC: Reliability of a new 3D wound measurement procedure and its accuracy in projected area.

Authors:  David Sánchez-Jiménez; Fernando F Buchón-Moragues; Begoña Escutia-Muñoz; Rafael Botella-Estrada
Journal:  Int Wound J       Date:  2021-05-18       Impact factor: 3.315

3.  Evaluation of upper labial frenectomy: A randomized, controlled comparative study of conventional scalpel technique and Er:YAG laser technique.

Authors:  Roxana Sarmadi; Pia Gabre; Andreas Thor
Journal:  Clin Exp Dent Res       Date:  2020-12-25
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.