Literature DB >> 28921034

Does nasal congestion have a role in decreased resistance to regular CPAP usage?

Ayşe İriz1, Mehmet Düzlü2, Oğuz Köktürk3, Yusuf Kemal Kemaloğlu1, Fakih Cihat Eravcı1, Mehmet Ekrem Zorlu1, Recep Karamert1.   

Abstract

Nasal obstruction is known to cause resistance to continuous positive airway pressure (CPAP) therapy in obstructive sleep apnea syndrome (OSAS). In this paper, short- and long-term nasal congestion in OSAS patients receiving CPAP treatment were evaluated with acoustic rhinometry (AR). A total of 36 patients with moderate-to-severe OSAS, diagnosed with polysomnography were included in the study. Ten healthy subjects without OSAS constituted the control group. Pre-treatment nasal patency were measured with AR in all participants. 26 patients used the recommended CPAP treatment. Ten patients did not accept CPAP treatment. The AR test was repeated for all the subjects after 1 and 3 months except the 3rd month's measurements of the control group. There was no statistically significant difference between the initial minimum cross-sectional area (MCA) measurements of OSAS patients, using or not using CPAP, and the control group (P > 0.05). However, the first month MCA measurements of patients receiving CPAP were found to be significantly decreased compared with the initial values (P < 0.001). There was no significant change in the first and third months MCA values in the control group and patients who did not use CPAP (P > 0.05). No significant difference revealed in the 3rd month MCA measurements of the patients using CPAP compared with the initial values (P > 0.05). In this study, the increased nasal congestion, which is thought to be the cause of CPAP resistance, was objectively demonstrated in OSAS patients using CPAP. In addition, the nasal congestion developing at the first month was shown to disappear over time, supporting the opinion that patient compliance in CPAP treatment is expected to increase after regular device usage.

Entities:  

Keywords:  Acoustic rhinometry; CPAP; OSAS

Mesh:

Year:  2017        PMID: 28921034     DOI: 10.1007/s00405-017-4744-z

Source DB:  PubMed          Journal:  Eur Arch Otorhinolaryngol        ISSN: 0937-4477            Impact factor:   2.503


  13 in total

1.  Influence of upper airway narrowing on the effective continuous positive airway pressure level.

Authors:  Hyo Yeol Kim; Jin-Young Min; Do-Yeon Cho; Seung-Kyu Chung; Hun-Jong Dhong
Journal:  Laryngoscope       Date:  2007-01       Impact factor: 3.325

2.  Long-term compliance with nasal continuous positive airway pressure therapy for sleep apnea syndrome in an otorhinolaryngological office.

Authors:  Takahiro Tokunaga; Takahiro Ninomiya; Yukinori Kato; Yumi Ito; Tetsuji Takabayashi; Masaharu Tokuriki; Hiroshi Sunaga; Shigeharu Fujieda
Journal:  Eur Arch Otorhinolaryngol       Date:  2013-04-09       Impact factor: 2.503

3.  Subjective, anatomical, and functional nasal evaluation of patients with obstructive sleep apnea syndrome.

Authors:  Tatiana de Aguiar Vidigal; Fernanda Louise Martinho Haddad; Luiz Carlos Gregório; Dalva Poyares; Sérgio Tufik; Lia Rita Azeredo Bittencourt
Journal:  Sleep Breath       Date:  2012-03-03       Impact factor: 2.816

4.  Long-term use of CPAP therapy for sleep apnea/hypopnea syndrome.

Authors:  N McArdle; G Devereux; H Heidarnejad; H M Engleman; T W Mackay; N J Douglas
Journal:  Am J Respir Crit Care Med       Date:  1999-04       Impact factor: 21.405

Review 5.  Positive airway pressure treatment for obstructive sleep apnea.

Authors:  Rahul K Kakkar; Richard B Berry
Journal:  Chest       Date:  2007-09       Impact factor: 9.410

6.  Upper airway pressure-flow relationships in obstructive sleep apnea.

Authors:  P L Smith; R A Wise; A R Gold; A R Schwartz; S Permutt
Journal:  J Appl Physiol (1985)       Date:  1988-02

Review 7.  Impact of impaired nasal breathing on sleep-disordered breathing.

Authors:  Thomas Verse; Wolfgang Pirsig
Journal:  Sleep Breath       Date:  2003-06       Impact factor: 2.816

8.  Effects of long-term nasal continuous positive airway pressure therapy on morphology, function, and mucociliary clearance of nasal epithelium in patients with obstructive sleep apnea syndrome.

Authors:  Roberto Bossi; Gioia Piatti; Elisabetta Roma; Umberto Ambrosetti
Journal:  Laryngoscope       Date:  2004-08       Impact factor: 3.325

Review 9.  Nasal involvement in obstructive sleep apnea syndrome.

Authors:  Daniel de Sousa Michels; Amanda da Mota Silveira Rodrigues; Márcio Nakanishi; André Luiz Lopes Sampaio; Alessandra Ramos Venosa
Journal:  Int J Otolaryngol       Date:  2014-11-20

10.  Initial adherence to autotitrating positive airway pressure therapy: influence of upper airway narrowing.

Authors:  Yoon Kyoung So; Hun-Jong Dhong; Hyo Yeol Kim; Seung-Kyu Chung; Jeon-Yeob Jang
Journal:  Clin Exp Otorhinolaryngol       Date:  2009-12-31       Impact factor: 3.372

View more
  4 in total

1.  Laryngopharyngeal reflux is a potential cause of nasal congestion and obstructive sleep apnea syndrome.

Authors:  Zhengcai Lou; Zi-Han Lou
Journal:  Eur Arch Otorhinolaryngol       Date:  2017-10-17       Impact factor: 2.503

Review 2.  Non-surgical treatment of obstructive sleep apnea syndrome.

Authors:  Xu Tingting; You Danming; Chen Xin
Journal:  Eur Arch Otorhinolaryngol       Date:  2017-11-24       Impact factor: 2.503

3.  The effect of unilateral forced nostril breathing on sleep in healthy right-handed men: a preliminary report.

Authors:  Deniz Ozturk; Omer Araz; Elif Yilmazel Ucar; Metin Akgun
Journal:  Sleep Breath       Date:  2018-03-01       Impact factor: 2.816

Review 4.  Nasal function and CPAP use in patients with obstructive sleep apnoea: a systematic review.

Authors:  Marina Brimioulle; Konstantinos Chaidas
Journal:  Sleep Breath       Date:  2021-09-02       Impact factor: 2.655

  4 in total