BACKGROUND:CT radiation is arguably carcinogenic. Results from single-centre studies, mostly retrospective, have advocated lowering the CT radiation dose for the diagnosis of appendicitis. However, adoption of low-dose CT has been slow. We aimed to assess the effectiveness of low-dose CT compared with standard-dose CT in the diagnosis of appendicitis in adolescents and young adults. METHODS: We did this pragmatic, multicentre, randomised controlled non-inferiority trial at 20 South Korean teaching hospitals with little experience with low-dose CT. Patients aged 15-44 years with suspected appendicitis were randomly assigned (1:1), via computer-generated random assignments (permuted block sizes of two, four, six, and eight) concealed in sequentially numbered envelopes, to receive low-dose CT (2 mSv) or standard-dose CT (≤8 mSv). Randomisation was stratified by site. Group allocation was concealed from patients, outcome assessors, and adverse event adjudicators; care providers, site pathologists, and data collectors were aware of allocation. The primary endpoint was the negative (unnecessary) appendectomy rate among all appendectomies, with a non-interiority margin of 4·5% for low-dose versus standard-dose CT. Primary analysis was by modified intention to treat, which included all patients who received an appendectomy in the group to which they were assigned. This trial is registered with ClinicalTrials.gov, number NCT01925014. FINDINGS: Between Dec 4, 2013, and Aug 18, 2016, we assigned 1535 patients to the low-dose CT group and 1539 patients to the standard-dose CT group. 22 (3·9%) of 559 patients had a negative appendectomy in the low-dose group versus 16 (2·7%) of 601 patients in the standard-dose group (difference 1·3%, 95% CI -0·8 to 3·3; p=0·0022 for the non-inferiority test). We recorded 43 adverse events in 43 (2·8%) of 1535 patients in the low-dose group and 41 adverse events in 40 (2·6%) of 1539 patients in the standard-dose group. One life-threatening adverse event of anaphylaxis caused by an iodinated contrast material occurred in the low-dose group. INTERPRETATION:Radiation dose of appendiceal CT for adolescents and young adults can be reduced to 2 mSv without impairing clinical outcomes. In view of the vast number of appendiceal CT examinations done worldwide, use of low-dose CT could prevent a sizeable number of radiation-associated cancers in the future. FUNDING: Korea Health Industry Development Institute, Seoul National University Bundang Hospital, Dasol Life Science, and Bracco Imaging Korea.
RCT Entities:
BACKGROUND:CT radiation is arguably carcinogenic. Results from single-centre studies, mostly retrospective, have advocated lowering the CT radiation dose for the diagnosis of appendicitis. However, adoption of low-dose CT has been slow. We aimed to assess the effectiveness of low-dose CT compared with standard-dose CT in the diagnosis of appendicitis in adolescents and young adults. METHODS: We did this pragmatic, multicentre, randomised controlled non-inferiority trial at 20 South Korean teaching hospitals with little experience with low-dose CT. Patients aged 15-44 years with suspected appendicitis were randomly assigned (1:1), via computer-generated random assignments (permuted block sizes of two, four, six, and eight) concealed in sequentially numbered envelopes, to receive low-dose CT (2 mSv) or standard-dose CT (≤8 mSv). Randomisation was stratified by site. Group allocation was concealed from patients, outcome assessors, and adverse event adjudicators; care providers, site pathologists, and data collectors were aware of allocation. The primary endpoint was the negative (unnecessary) appendectomy rate among all appendectomies, with a non-interiority margin of 4·5% for low-dose versus standard-dose CT. Primary analysis was by modified intention to treat, which included all patients who received an appendectomy in the group to which they were assigned. This trial is registered with ClinicalTrials.gov, number NCT01925014. FINDINGS: Between Dec 4, 2013, and Aug 18, 2016, we assigned 1535 patients to the low-dose CT group and 1539 patients to the standard-dose CT group. 22 (3·9%) of 559 patients had a negative appendectomy in the low-dose group versus 16 (2·7%) of 601 patients in the standard-dose group (difference 1·3%, 95% CI -0·8 to 3·3; p=0·0022 for the non-inferiority test). We recorded 43 adverse events in 43 (2·8%) of 1535 patients in the low-dose group and 41 adverse events in 40 (2·6%) of 1539 patients in the standard-dose group. One life-threatening adverse event of anaphylaxis caused by an iodinated contrast material occurred in the low-dose group. INTERPRETATION: Radiation dose of appendiceal CT for adolescents and young adults can be reduced to 2 mSv without impairing clinical outcomes. In view of the vast number of appendiceal CT examinations done worldwide, use of low-dose CT could prevent a sizeable number of radiation-associated cancers in the future. FUNDING: Korea Health Industry Development Institute, Seoul National University Bundang Hospital, Dasol Life Science, and Bracco Imaging Korea.
Authors: Ji Hoon Park; Jong-June Jeon; Sung Soo Lee; Amar C Dhanantwari; Ji Ye Sim; Hae Young Kim; Kyoung Ho Lee Journal: Eur Radiol Date: 2017-12-07 Impact factor: 5.315
Authors: Salomone Di Saverio; Mauro Podda; Belinda De Simone; Marco Ceresoli; Goran Augustin; Alice Gori; Marja Boermeester; Massimo Sartelli; Federico Coccolini; Antonio Tarasconi; Nicola De' Angelis; Dieter G Weber; Matti Tolonen; Arianna Birindelli; Walter Biffl; Ernest E Moore; Michael Kelly; Kjetil Soreide; Jeffry Kashuk; Richard Ten Broek; Carlos Augusto Gomes; Michael Sugrue; Richard Justin Davies; Dimitrios Damaskos; Ari Leppäniemi; Andrew Kirkpatrick; Andrew B Peitzman; Gustavo P Fraga; Ronald V Maier; Raul Coimbra; Massimo Chiarugi; Gabriele Sganga; Adolfo Pisanu; Gian Luigi De' Angelis; Edward Tan; Harry Van Goor; Francesco Pata; Isidoro Di Carlo; Osvaldo Chiara; Andrey Litvin; Fabio C Campanile; Boris Sakakushev; Gia Tomadze; Zaza Demetrashvili; Rifat Latifi; Fakri Abu-Zidan; Oreste Romeo; Helmut Segovia-Lohse; Gianluca Baiocchi; David Costa; Sandro Rizoli; Zsolt J Balogh; Cino Bendinelli; Thomas Scalea; Rao Ivatury; George Velmahos; Roland Andersson; Yoram Kluger; Luca Ansaloni; Fausto Catena Journal: World J Emerg Surg Date: 2020-04-15 Impact factor: 5.469
Authors: Suvi Sippola; Juha Grönroos; Ville Sallinen; Tero Rautio; Pia Nordström; Tuomo Rantanen; Saija Hurme; Ari Leppäniemi; Sanna Meriläinen; Johanna Laukkarinen; Heini Savolainen; Johanna Virtanen; Paulina Salminen Journal: BMJ Open Date: 2018-11-03 Impact factor: 2.692
Authors: Kyung Hee Lee; Seungjae Lee; Ji Hoon Park; Sung Soo Lee; Hae Young Kim; Won Jin Lee; Eun Shil Cha; Kwang Pyo Kim; Woojoo Lee; Ji Yun Lee; Kyoung Ho Lee Journal: JAMA Surg Date: 2021-04-01 Impact factor: 14.766