Literature DB >> 28918767

Refractive Index Imaging of Cells with Variable-Angle Near-Total Internal Reflection (TIR) Microscopy.

Kevin P Bohannon1, Ronald W Holz1, Daniel Axelrod2.   

Abstract

The refractive index in the interior of single cells affects the evanescent field depth in quantitative studies using total internal reflection (TIR) fluorescence, but often that index is not well known. We here present method to measure and spatially map the absolute index of refraction in a microscopic sample, by imaging a collimated light beam reflected from the substrate/buffer/cell interference at variable angles of incidence. Above the TIR critical angle (which is a strong function of refractive index), the reflection is 100%, but in the immediate sub-critical angle zone, the reflection intensity is a very strong ascending function of incidence angle. By analyzing the angular position of that edge at each location in the field of view, the local refractive index can be estimated. In addition, by analyzing the steepness of the edge, the distance-to-substrate can be determined. We apply the technique to liquid calibration samples, silica beads, cultured Chinese hamster ovary cells, and primary culture chromaffin cells. The optical technique suffers from decremented lateral resolution, scattering, and interference artifacts. However, it still provides reasonable results for both refractive index (~1.38) and for distance-to-substrate (~150 nm) for the cells, as well as a lateral resolution to about 1 µm.

Entities:  

Keywords:  cellular imaging; evanescent wave; index of refraction; microscope optics; total internal reflection

Mesh:

Year:  2017        PMID: 28918767      PMCID: PMC7790292          DOI: 10.1017/S1431927617012570

Source DB:  PubMed          Journal:  Microsc Microanal        ISSN: 1431-9276            Impact factor:   4.127


  36 in total

1.  Quantitative phase microscopy via optimized inversion of the phase optical transfer function.

Authors:  Micah H Jenkins; Thomas K Gaylord
Journal:  Appl Opt       Date:  2015-10-01       Impact factor: 1.980

Review 2.  Secretory granule behaviour adjacent to the plasma membrane before and during exocytosis: total internal reflection fluorescence microscopy studies.

Authors:  R W Holz; D Axelrod
Journal:  Acta Physiol (Oxf)       Date:  2007-11-16       Impact factor: 6.311

3.  Simultaneous cell morphometry and refractive index measurement with dual-wavelength digital holographic microscopy and dye-enhanced dispersion of perfusion medium.

Authors:  Benjamin Rappaz; Florian Charrière; Christian Depeursinge; Pierre J Magistretti; Pierre Marquet
Journal:  Opt Lett       Date:  2008-04-01       Impact factor: 3.776

4.  Elastic scattering of evanescent electromagnetic waves.

Authors:  H Chew; D S Wang; M Kerker
Journal:  Appl Opt       Date:  1979-08-01       Impact factor: 1.980

5.  Whole-cell scan using automatic variable-angle and variable-illumination-depth pseudo-total internal reflection fluorescence microscopy.

Authors:  Wei Sun; Aoshuang Xu; Kyle Marchuk; Gufeng Wang; Ning Fang
Journal:  J Lab Autom       Date:  2011-04-01

Review 6.  Evanescent excitation and emission in fluorescence microscopy.

Authors:  Daniel Axelrod
Journal:  Biophys J       Date:  2013-04-02       Impact factor: 4.033

7.  Thickness and refractive index of DPPC and DPPE monolayers by multiple-beam interferometry.

Authors:  Daniel F Kienle; João V de Souza; Erik B Watkins; Tonya L Kuhl
Journal:  Anal Bioanal Chem       Date:  2014-05-21       Impact factor: 4.142

8.  Eliminating unwanted far-field excitation in objective-type TIRF. Part I. identifying sources of nonevanescent excitation light.

Authors:  Maia Brunstein; Maxime Teremetz; Karine Hérault; Christophe Tourain; Martin Oheim
Journal:  Biophys J       Date:  2014-03-04       Impact factor: 4.033

9.  Zero-cost modification of bright field microscopes for imaging phase gradient on cells: Schlieren optics.

Authors:  D Axelrod
Journal:  Cell Biophys       Date:  1981-06

10.  Measurement of single cell refractive index, dry mass, volume, and density using a transillumination microscope.

Authors:  Kevin G Phillips; Steven L Jacques; Owen J T McCarty
Journal:  Phys Rev Lett       Date:  2012-09-13       Impact factor: 9.161

View more
  3 in total

1.  Variable incidence angle linear dichroism (VALiD): a technique for unique 3D orientation measurement of fluorescent ensembles.

Authors:  Aaron T Blanchard; Joshua M Brockman; Khalid Salaita; Alexa L Mattheyses
Journal:  Opt Express       Date:  2020-03-30       Impact factor: 3.894

2.  Optometry for a short-sighted microscope.

Authors:  Carine Julien; Martin Oheim
Journal:  Biophys J       Date:  2021-09-10       Impact factor: 3.699

3.  Light scattering in TIRF microscopy: A theoretical study of the limits to surface selectivity.

Authors:  Jeremy J Axelrod; Daniel Axelrod
Journal:  Biophys J       Date:  2021-06-30       Impact factor: 3.699

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.