| Literature DB >> 28918454 |
Abstract
BACKGROUND: Thermotactile thresholds and vibrotactile thresholds are measured to assist the diagnosis of the sensorineural component of the hand-arm vibration syndrome (HAVS).Entities:
Keywords: Hand-transmitted vibration; Hand–arm vibration syndrome; Sensorineural dysfunction; Thermotactile thresholds; Vibrotactile perception thresholds
Mesh:
Year: 2017 PMID: 28918454 PMCID: PMC5752730 DOI: 10.1007/s00420-017-1259-2
Source DB: PubMed Journal: Int Arch Occup Environ Health ISSN: 0340-0131 Impact factor: 3.015
Parameters of the HVLab thermal aesthesiometer and HVLab vibrotactile perception meter
| Parameter | Condition |
|---|---|
| Thermotactile thresholds | |
| Contact area | Circular, 5.5 cm diameter |
| Contact surface | Smooth and planar |
| Psychophysical method | Method of limits |
| Number of judgements | Six hot or cold |
| Reference temperature | 32.5 °C |
| Rate of change in temperature | 1 °C/s |
| Vibrotactile thresholds | |
| Probe diameter | 6 mm |
| Probe surround gap | 2 mm |
| Contactor surface | Smooth and planar |
| Psychophysical method | von Békésy |
| Number of judgements | At least six peaks and troughs |
| Rate of change in stimulus | 3 dB/s |
| Push force | 2 N |
Diagnostic criteria for hot and cold thresholds and vibrotactile thresholds at 31.5 and 125 Hz
| Test | Possible dysfunction | Definite dysfunction |
|---|---|---|
| Hot threshold (°C) | >45 | >48.5 |
| Cold threshold (°C) | <22 | <19 |
| 31.5 Hz threshold (m/s2, r.m.s.) | >0.3 | >0.4 |
| 125 Hz threshold (m/s2, r.m.s.) | >0.7 | >1.0 |
Possible dysfunction is identified when the measured threshold differs from thresholds measured in a reference group of males without symptoms by more than the mean plus one standard deviation, and definite dysfunction is assumed when the difference is greater than the mean plus two standard deviations (Lindsell and Griffin 1998, 2002)
Medians (and inter-quartile ranges) of hot thresholds, cold thresholds, neutral zones, and vibrotactile thresholds at 31.5 and 125 Hz on the distal phalanges of fingers with sensorineural symptoms (Group A) and fingers without sensorineural symptoms (Group B)
| 154 fingers with any sensorineural symptom (Group A) | 86 fingers without any sensorineural symptom (Group B) | |
|---|---|---|
| Hot thresholds (°C) | 48.2 (45.7–50.9)** | 41.4 (39.2–43.0) |
| Cold thresholds (°C) | 16.8 (14.2–21.3)** | 25.8 (24.3–28.0) |
| Neutral zone (°C) | 30.6 (24.4–32.7)** | 15.3 (13.8–19.7) |
| Thresholds, 31.5 Hz (m/s2 r.m.s.) | 0.41 (0.34–0.59)** | 0.17 (0.14–0.25) |
| Thresholds, 125 Hz (m/s2 r.m.s.) | 1.19 (0.86–1.72)** | 0.35 (0.28–0.61) |
* p < 0.01, ** p < 0.001: significant increase in hot threshold or decrease in cold thresholds on fingers with sensorineural symptoms compared to fingers without sensorineural symptoms (Mann–Whitney U test)
Fig. 1Receiver operating characteristics (ROC) curves for sensorineural symptoms (top) and finger whiteness (bottom) calculated for hot and cold thresholds and vibrotactile thresholds at 31.5 and 125 Hz. The ROC curves are shown for sensorineural scores of 1, 3, and 6 and for finger whiteness scores of 1, 3, or 6. Data from 60 subjects
Fig. 2Associations between a hot and cold thresholds, b vibrotactile thresholds at 31.5 and 125 Hz, c vibrotactile thresholds at 31.5 Hz and cold thresholds and d vibrotactile thresholds at 31.5 and hot thresholds in fingers with sensorineural scores of 0, 1, 3, and 6. Broken lines indicate diagnostic criteria for possible dysfunction (see Table 2). Data from 60 subjects
Sensitivity, specificity, and area under the ROC curve (AUC) calculated for thermotactile and vibrotactile thresholds using symptoms of numbness, tingling, and whiteness
| Measure | Numbness | Tingling | Whiteness | ||||||
|---|---|---|---|---|---|---|---|---|---|
| Sen. (%) | Spec. (%) | AUC | Sen. (%) | Spec. (%) | AUC | Sen. (%) | Spec. (%) | AUC | |
| Hot thresholds | 80 | 91 | 0.88 | 76 | 83 | 0.82 | 53 | 65 | 0.60 |
| Cold thresholds | 85 | 92 | 0.94 | 82 | 88 | 0.87 | 50 | 63 | 0.59 |
| Vibrotactile thresholds at 31.5 Hz | 77 | 88 | 0.85 | 73 | 85 | 0.82 | 49 | 64 | 0.58 |