Literature DB >> 28918145

Short communication: Relationship between methods for measurement of serum electrolytes and the relationship between ionized and total calcium and neutrophil oxidative burst activity in early postpartum dairy cows.

B M Leno1, E M Martens1, M J B Felippe2, K P Zanzalari3, J C Lawrence4, T R Overton5.   

Abstract

The objectives of this study were to (1) compare a test for serum measurement of total Ca (tCa), Mg, and P (VetTest Chemistry Analyzer, IDEXX Laboratories Inc., Westbrook, ME) to reference methods (spectrophotometric assays on a Beckman Coulter 640e automated clinical chemistry analyzer; Beckman Coulter, Brea, CA), (2) determine the relationship between ionized Ca (iCa) and reference method tCa in the immediate postpartum period, and (3) assess the relative value of these blood Ca indices as predictors of neutrophil oxidative burst activity. Samples were collected from multiparous Holstein cows (n = 33) over the first 5 d in milk. A total of 183 samples for objective 1 and 181 samples for objective 2 were available. Neutrophil oxidative burst activity was assessed once between 2 and 5 d in milk (n = 29). Linear regression demonstrated strong relationships between serum tCa, Mg, and P concentrations measured by the VetTest compared with the reference method. Bland Altman analysis indicated that the VetTest values were higher than the reference method by 0.22 mmol/L for tCa, 0.12 mmol/L for Mg, and 0.16 mmol/L for P. Compared with hypocalcemia categorized at ≤2.0 or ≤2.125 mmol/L with the reference method tCa, thresholds for the VetTest measured tCa of ≤2.23 mmol/L (sensitivity = 87%, specificity = 89%) or ≤2.30 mmol/L (sensitivity = 86%, specificity = 96%) could be used. The relationship between whole-blood iCa and reference method serum tCa differed by sampling time point after calving. Compared with identification of hypocalcemia with serum tCa measurements from the reference method (thresholds of ≤2.0 and 2.125 mmol/L), a whole-blood iCa threshold of ≤1.17 mmol/L resulted in the highest combined sensitivities (94 and 82%) and specificities (80 and 94%) at either threshold. Ionized Ca measurements were more consistently related to outcomes of neutrophil oxidative burst activity measured in vitro. The VetTest measurements of serum tCa reliably identified hypocalcemia when thresholds were adjusted to account for the bias of the test. The variation in the relationship between iCa and reference method tCa in the days following parturition suggest that these measures cannot be used interchangeably as indicators of Ca status. The more consistent associations between iCa and in vitro measures of neutrophil function, compared with tCa, indicated that this may be a more sensitive predictor of functional outcomes associated with postpartum Ca status.
Copyright © 2017 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  calcium; neutrophils

Mesh:

Substances:

Year:  2017        PMID: 28918145     DOI: 10.3168/jds.2017-12971

Source DB:  PubMed          Journal:  J Dairy Sci        ISSN: 0022-0302            Impact factor:   4.034


  4 in total

1.  Effect of induced hypocalcemia in nonlactating, nonpregnant Holstein cows fed negative DCAD with low, medium, or high concentrations of calcium.

Authors:  Laura A Amundson; Angela D Rowson; Peter M Crump; Austin P Prichard; Adrienne A Cheng; Collin E Wimmler; Marisa Klister; Samantha R Weaver; Scott S Bascom; Dennis E Nuzback; Ken P Zanzalari; Laura L Hernandez
Journal:  J Anim Sci       Date:  2018-12-03       Impact factor: 3.159

2.  Validation of the bovine blood calcium checker as a rapid and simple measuring tool for the ionized calcium concentration in cattle.

Authors:  Kazuyuki Suzuki; Nao Kondo; Kaede Takagi; Akitoyo Nishikawa; Yoshiki Murakami; Marina Otsuka; Kenji Tsukano; Keiko Ikeda; Hisashi Funakura; Ichiro Yasutomi; Satoshi Kawamoto
Journal:  J Vet Med Sci       Date:  2021-03-26       Impact factor: 1.267

3.  Changes in ionized calcium concentration in the blood of dairy cows with peracute coliform mastitis.

Authors:  Keiichi Hisaeda; Tomoko Koshiishi; Ayuna Sasaki; Yasunori Shinozuka; Naoki Isobe; Kazuhiro Kawai
Journal:  J Vet Med Sci       Date:  2020-02-26       Impact factor: 1.267

4.  Comparison of the bovine blood gas parameters produced with three types of portable blood gas analyzers.

Authors:  Younghye Ro; Woojae Choi; Leegon Hong; Eunkyung Kim; Eunhui Choe; Danil Kim
Journal:  J Vet Sci       Date:  2022-07       Impact factor: 1.603

  4 in total