Literature DB >> 28917801

Development of a quantitative approach in blood plasma for low-dosed hallucinogens and opioids using LC-high resolution mass spectrometry.

Achim T Caspar1, Andreas B Kollas1, Hans H Maurer1, Markus R Meyer2.   

Abstract

The WHO annually reports an increasing abuse of new psychoactive substances (NPS), which are a heterogeneous group of synthetic drugs and are consumed as substitute for controlled drugs of abuse. In this work, we focused on highly potent derivatives such those of phenethylamine (2C), N-2-methoxybenzyl phenethylamine (NBOMes), lysergic acid diethylamide (LSD), and fentanyl. Severe to fatal intoxications were described due to their high potency. Therefore, they have to be taken at very low doses resulting in low blood concentration in the low ng/mL range, which is a challenge for reliable analytical detection and quantification. The aim of this work was therefore to design a simple, robust, and fast method for simultaneous detection and quantification of multiple substances of the different classes in human blood plasma using liquid chromatography (LC) high resolution (HR) mass spectrometry (MS) with alternating HR full-scan (HRFS) MS and "All-ions fragmentation" (AIF) MS. The paper contains results of the method validation according to the EMA guideline, including intra-/interday accuracy and precision, matrix effects, storage and benchtop analyte stability as well as selectivity and carryover. All validation criteria were fulfilled for most tested compounds except for the NBOMe derivatives, one out of ten 2C-derivatives and butyryl fentanyl, which failed at accuracy and/or precision or at the acceptance criteria for matrix effect. Reasons for this are discussed and solutions presented. Despite some limitations, the HRFS + AIFMS analysis allowed detection of most of the analytes down to 0.1ng/mL, seamless integration of new or unexpected analytes, identification and quantification with no limitations on the number of monitored compounds, and reevaluation of the acquired data also concerning metabolism studies using group-indicating fragment ions.
Copyright © 2017 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Analytical toxicology; Drugs of abuse; High resolution mass spectrometry; New psychoactive substances; Plasma quantification

Mesh:

Substances:

Year:  2017        PMID: 28917801     DOI: 10.1016/j.talanta.2017.08.063

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  3 in total

Review 1.  1H Nuclear Magnetic Resonance: A Future Approach to the Metabolic Profiling of Psychedelics in Human Biofluids?

Authors:  Sylvana Vilca-Melendez; Malin V Uthaug; Julian L Griffin
Journal:  Front Psychiatry       Date:  2021-12-13       Impact factor: 4.157

2.  [Analysis of 29 fentanyl analogs and their fragmentation mechanism by liquid chromatography-quadrupole time-of-flight mass spectrometry].

Authors:  Zhenlin Dong; Chunguang Yang; Tian Xu; Di Dai; Lu Gao; Lu Yang; Qiuyan Wang
Journal:  Se Pu       Date:  2022-01

3.  Hyphenated high-resolution mass spectrometry-the "all-in-one" device in analytical toxicology?

Authors:  Hans H Maurer
Journal:  Anal Bioanal Chem       Date:  2020-11-28       Impact factor: 4.142

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.