Literature DB >> 28917787

Gas chromatographic-mass spectrometric analysis of urinary volatile organic metabolites: Optimization of the HS-SPME procedure and sample storage conditions.

Tanja Živković Semren1, Irena Brčić Karačonji1, Toni Safner2, Nataša Brajenović1, Blanka Tariba Lovaković3, Alica Pizent1.   

Abstract

Non-targeted metabolomics research of human volatile urinary metabolome can be used to identify potential biomarkers associated with the changes in metabolism related to various health disorders. To ensure reliable analysis of urinary volatile organic metabolites (VOMs) by gas chromatography-mass spectrometry (GC-MS), parameters affecting the headspace-solid phase microextraction (HS-SPME) procedure have been evaluated and optimized. The influence of incubation and extraction temperatures and times, coating fibre material and salt addition on SPME efficiency was investigated by multivariate optimization methods using reduced factorial and Doehlert matrix designs. The results showed optimum values for temperature to be 60°C, extraction time 50min, and incubation time 35min. The proposed conditions were applied to investigate urine samples' stability regarding different storage conditions and freeze-thaw processes. The sum of peak areas of urine samples stored at 4°C, -20°C, and -80°C up to six months showed a time dependent decrease over time although storage at -80°C resulted in a slight non-significant reduction comparing to the fresh sample. However, due to the volatile nature of the analysed compounds, more than two cycles of freezing/thawing of the sample stored for six months at -80°C should be avoided whenever possible.
Copyright © 2017 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  HS-SPME procedure; Metabolomic; Sample stability; Urine samples; Volatile organic metabolites

Mesh:

Substances:

Year:  2017        PMID: 28917787     DOI: 10.1016/j.talanta.2017.08.064

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  6 in total

1.  Global Plasma Profiling for Colorectal Cancer-Associated Volatile Organic Compounds: a Proof-of-Principle Study.

Authors:  Seongho Kim; Xinmin Yin; Md Aminul Islam Prodhan; Xiang Zhang; Zichun Zhong; Ikuko Kato
Journal:  J Chromatogr Sci       Date:  2019-05-01       Impact factor: 1.618

2.  Lichen Planopilaris: The first biopsy layer microbiota inspection.

Authors:  Daniela Pinto; Francesco Maria Calabrese; Maria De Angelis; Giuseppe Celano; Giammaria Giuliani; Fabio Rinaldi
Journal:  PLoS One       Date:  2022-07-18       Impact factor: 3.752

3.  Predictive Metagenomic Profiling, Urine Metabolomics, and Human Marker Gene Expression as an Integrated Approach to Study Alopecia Areata.

Authors:  Daniela Pinto; Francesco Maria Calabrese; Maria De Angelis; Giuseppe Celano; Giammaria Giuliani; Marco Gobbetti; Fabio Rinaldi
Journal:  Front Cell Infect Microbiol       Date:  2020-04-29       Impact factor: 5.293

Review 4.  Volatilomics: An Emerging and Promising Avenue for the Detection of Potential Prostate Cancer Biomarkers.

Authors:  Cristina V Berenguer; Ferdinando Pereira; Jorge A M Pereira; José S Câmara
Journal:  Cancers (Basel)       Date:  2022-08-17       Impact factor: 6.575

5.  Chemical Characterization of the Marking Fluid of Breeding and Non-Breeding Male Cheetahs.

Authors:  Alexia Tommasi; Andreas G J Tredoux; Jacek A Koziel; Giulia Esposito
Journal:  Animals (Basel)       Date:  2022-09-03       Impact factor: 3.231

6.  An Optimization of Liquid-Liquid Extraction of Urinary Volatile and Semi-Volatile Compounds and Its Application for Gas Chromatography-Mass Spectrometry and Proton Nuclear Magnetic Resonance Spectroscopy.

Authors:  Natalia Drabińska; Piotr Młynarz; Ben de Lacy Costello; Peter Jones; Karolina Mielko; Justyna Mielnik; Raj Persad; Norman Mark Ratcliffe
Journal:  Molecules       Date:  2020-08-11       Impact factor: 4.411

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.