| Literature DB >> 28917770 |
Lorenzo Ciofi1, Lapo Renai1, Daniele Rossini1, Claudia Ancillotti1, Alida Falai2, Donatella Fibbi3, Maria Concetta Bruzzoniti4, José Juan Santana-Rodriguez5, Serena Orlandini1, Massimo Del Bubba6.
Abstract
The applicability of a direct injection UHPLC-MS/MS method for the analysis of several perfluoroalkyl acids (PFAAs) in a wide range of water matrices was investigated. The method is based on the direct injection of 100µL of centrifuged water sample, without any other sample treatment. Very good method detection limits (0.014-0.44ngL-1) and excellent intra and inter-day precision (RSD% values in the range 1.8-4.4% and 2.7-5.7%, respectively) were achieved, with a total analysis time of 20min per sample. A high number of samples - i.e. 8 drinking waters (DW), 12 ground waters (GW), 13 surface waters (SW), 8 influents and 11 effluents of wastewater treatment plants (WWTPIN and WWTPOUT) were processed and the extent of matrix effect (ME) was calculated, highlighting the strong prevalence of |ME| < 20%. The occurrence of |ME| > 50% was occasionally observed only for perfluorooctanesulphonic and perfluorodecanoic acids. Linear discriminant analysis highlighted the great contribution of the sample origin (i.e. DW, GW, SW, WWTPIN and WWTPOUT) to the ME. Partial least square regression (PLS) and leave-one-out cross-validation were performed in order to interpret and predict the signal suppression or enhancement phenomena as a function of physicochemical parameters of water samples (i.e. conductivity, hardness and chemical oxygen demand) and background chromatographic area. The PLS approach resulted only in an approximate screening, due to the low prediction power of the PLS models. However, for most analytes in most samples, the fitted and cross-validated values were such as to correctly distinguish between | ME | higher than 20% or below this limit. PFAAs in the aforementioned water samples were quantified by means of the standard addition method, highlighting their occurrence mainly in WWTP influents and effluents, at concentrations as high as one hundred of µgL-1.Entities:
Keywords: Direct injection UHPLC-MS/MS; Drinking water; Environmental water; Matrix effect chemometrics; Perfluoroalkyl acids; Wastewater
Mesh:
Substances:
Year: 2017 PMID: 28917770 DOI: 10.1016/j.talanta.2017.08.052
Source DB: PubMed Journal: Talanta ISSN: 0039-9140 Impact factor: 6.057