Literature DB >> 28917760

Rapid and sensitive serum glucose determination using chemical labeling coupled with black phosphorus-assisted laser desorption/ionization time-of-flight mass spectrometry.

Qing Wang1, Lei Yu1, Chu-Bo Qi2, Jun Ding1, Xiao-Mei He1, Ren-Qi Wang3, Yu-Qi Feng4.   

Abstract

Monitoring the concentration of blood glucose in patients is a key component of good medical diagnoses. Therefore, developing an accurate, rapid and sensitive strategy for monitoring blood glucose is of vital importance. We proposed a strategy for serum glucose determination combining 2-(4-boronobenzyl) isoquinolin-2-ium bromide chemical labeling with black phosphorus assisted laser desorption ionization-time of flight mass spectrometry (CL-BP/ALDI-TOF MS). The entire analytical process consisted of 1min of protein precipitation and 3min of chemical labeling in a microwave oven prior to the BP/ALDI-TOF MS analysis. The analysis can be completed in 5min with high throughput and extremely low sample consumption. Good linearity for glucose was obtained with a correlation coefficient (R) of 0.9986. The limit of detection (LOD) and limit of quantification (LOQ) were 11.5 fmol and 37.5 fmol, respectively. Satisfied reproducibility and reliability were gained by evaluation of the intra- and inter-day precisions with relative standard deviations (RSDs) less than 7.2% and relative recoveries ranging from 87.1% to 108.1%, respectively. The proposed strategy was also applied for the analysis of endogenous glucose in various serum samples and the results were consistent with those obtained using the hexokinase method in a clinical laboratory. Considering the results, the proposed CL-BP/ALDI-TOF MS strategy has proven to be reliable, fast, and sensitive for quantitative analysis of serum glucose.
Copyright © 2017 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Black phosphorus matrix; Chemical labeling; Matrix assisted laser desorption ionization-time of flight mass spectrometry; Serum glucose

Mesh:

Substances:

Year:  2017        PMID: 28917760     DOI: 10.1016/j.talanta.2017.08.055

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  3 in total

1.  Fe/C magnetic nanocubes with enhanced peroxidase mimetic activity for colorimetric determination of hydrogen peroxide and glucose.

Authors:  Fencheng Yang; Guodong Jiang; Feng Yan; Qing Chang
Journal:  Mikrochim Acta       Date:  2019-06-11       Impact factor: 5.833

2.  A boronic acid modified binary matrix consisting of boron nitride and α-cyano-4-hydroxycinnamic acid for determination of cis-diols by MALDI-TOF MS.

Authors:  Ya-Shun Chen; Hua-Ming Xiao; Tian-Qi Wang; Lei Yu; Yu-Qi Feng
Journal:  Mikrochim Acta       Date:  2019-08-01       Impact factor: 5.833

3.  Matrix enrichment by black phosphorus improves ionization and reproducibility of mass spectrometry of intact cells, peptides, and amino acids.

Authors:  Govinda Mandal; Lukáš Moráň; Lukáš Pečinka; Petr Vaňhara; Josef Havel
Journal:  Sci Rep       Date:  2022-01-21       Impact factor: 4.379

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.