Effectiveness of Bone Suppression Imaging in the Detection of Lung Nodules on Chest Radiographs: Relevance to Anatomic Location and Observer's Experience.

Tomohiro Miyoshi1, Junji Yoshida, Nao Aramaki, Yuki Matsumura, Keiju Aokage, Tomoyuki Hishida, Tsuyoshi Kobayashi, Shinichi Tsubura, Shinsuke Katsuhara, Satoshi Kasai, Yasuhiko Sasano, Kanji Nagai, Masahiro Tsuboi.   

Abstract

OBJECTIVE: To evaluate the effectiveness of bone suppression imaging (BSI) software in lung-nodule detection on chest radiographs (CXRs) in relation to nodule location and observer's experience.
MATERIALS AND METHODS: The CXRs of 80 patients, of which 40 had a lung nodule (8 to 30 mm in diameter) and 40 did not have any nodules, were interpreted by 20 observers comprising of 7 pulmonologists with >10 years of experience and 13 pulmonology residents. Each patient's image was sequentially read, first using the standard CXR and thereafter with the BSI software. The nodule location and confidence level with regard to the presence of a lung nodule were recorded. Receiver operating characteristic analysis was used to evaluate observer performance.
RESULTS: The average area under the curve (AUC) for the observers' receiver operating characteristic significantly improved from 0.867 to 0.900 (P=0.004) with the use of the BSI software. The average AUC for experienced pulmonologists improved from 0.877 to 0.924 (P=0.017) for lung nodules located in the apical and peripheral areas but not for those in the inner area. The average AUC for residents improved regardless of nodule location.
CONCLUSION: The use of BSI software improved the performance in lung-nodule detection on CXRs regardless of observer's experience and was more effective for observers with limited experience.

Entities:  

Mesh:

Year:  2017        PMID: 28914743     DOI: 10.1097/RTI.0000000000000299

Source DB:  PubMed          Journal:  J Thorac Imaging        ISSN: 0883-5993            Impact factor:   3.000


  3 in total

Review 1.  Dynamic Chest X-Ray Using a Flat-Panel Detector System: Technique and Applications.

Authors:  Akinori Hata; Yoshitake Yamada; Rie Tanaka; Mizuki Nishino; Tomoyuki Hida; Takuya Hino; Masako Ueyama; Masahiro Yanagawa; Takeshi Kamitani; Atsuko Kurosaki; Shigeru Sanada; Masahiro Jinzaki; Kousei Ishigami; Noriyuki Tomiyama; Hiroshi Honda; Shoji Kudoh; Hiroto Hatabu
Journal:  Korean J Radiol       Date:  2020-11-30       Impact factor: 3.500

2.  Bone Suppression on Chest Radiographs for Pulmonary Nodule Detection: Comparison between a Generative Adversarial Network and Dual-Energy Subtraction.

Authors:  Kyungsoo Bae; Dong Yul Oh; Il Dong Yun; Kyung Nyeo Jeon
Journal:  Korean J Radiol       Date:  2022-01       Impact factor: 3.500

3.  Added Value of Bone Suppression Image in the Detection of Subtle Lung Lesions on Chest Radiographs with Regard to Reader's Expertise.

Authors:  Gil Sun Hong; Kyung Hyun Do; Choong Wook Lee
Journal:  J Korean Med Sci       Date:  2019-10-07       Impact factor: 2.153