Literature DB >> 28910163

Anterior Lens Capsule and Iris Thicknesses in Pseudoexfoliation Syndrome.

Muhammed Batur1, Erbil Seven1, Serek Tekin1, Tekin Yasar1.   

Abstract

PURPOSE: The aim of this study was to evaluate anatomic properties of the lens capsule and iris by anterior segment optical coherence tomography (AS-OCT) in patients with pseudoexfoliation (PEX).
METHODS: This prospective study included 62 eyes of 62 patients with PEX syndrome and 43 eyes of 43 age- and gender-matched controls. All subjects underwent full ophthalmologic examinations including AS-OCT. Pupillary diameter, midperipheral stromal iris thickness, central and temporal lens capsule thicknesses, and peripheral pseudoexfoliation material thickness on the anterior lens capsule surface were measured and recorded.
RESULTS: Mean age was 66.8 ± 9.3 years in the PEX group and 65.5 ± 8.9 years in the control group (p = 0.44). The PEX group consisted of 62 patients: 38 men (61.3%) and 24 women (38.7%); the control group included 43 subjects: 25 men (58.1%) and 18 women (41.9%). Pupillary diameter after pharmacologic mydriasis was 21% smaller in the PEX group than controls. Mean midperipheral iris thickness was 36 ± 7.2 μm (7.8%) thinner in the PEX group than that of control group (p = 0.047). The central anterior capsule was a mean of 3.40 ± 0.51 μm (18%) thicker in the PEX group compared to the control group (p = 0.0001). The temporal anterior lens capsule was a mean of 0.17 ± 0.15 μm thicker in the PEX group compared to the control group (p = 0.81).
CONCLUSIONS: With high-resolution OCT imaging, it has become possible to evaluate the anterior lens capsule without histologic examination and demonstrate that it is thicker than normal in PEX patients.

Entities:  

Keywords:  Iris; optical coherence tomography; pseudoexfoliation syndrome; pupillary diameter

Mesh:

Year:  2017        PMID: 28910163     DOI: 10.1080/02713683.2017.1338349

Source DB:  PubMed          Journal:  Curr Eye Res        ISSN: 0271-3683            Impact factor:   2.424


  4 in total

Review 1.  Pathological Changes of the Anterior Lens Capsule.

Authors:  Wei Liu; Dandan Huang; Ruru Guo; Jian Ji
Journal:  J Ophthalmol       Date:  2021-05-04       Impact factor: 1.909

2.  Determination of iris thickness development in children using swept-source anterior-segment optical coherence tomography.

Authors:  Shunsuke Nakakura; Yuki Nagata; Yukiko Shimizu; Akiko Kawai; Hitoshi Tabuchi; Yoshiaki Kiuchi
Journal:  PLoS One       Date:  2019-05-28       Impact factor: 3.240

Review 3.  Anterior segment optical coherence tomography for evaluation of cornea and ocular surface.

Authors:  Mittanamalli S Sridhar; Raul Martin
Journal:  Indian J Ophthalmol       Date:  2018-03       Impact factor: 1.848

Review 4.  Diagnostic imaging versus surgical procedure: intra- and postoperative OCT evaluation of sutureless scleral-fixated intraocular lens implantation and possible related complications.

Authors:  Raffaele Nuzzi; Alessandro Rossi
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2021-03-12       Impact factor: 3.117

  4 in total