PEAK HIP MUSCLE TORQUE MEASUREMENTS ARE INFLUENCED BY SAGITTAL PLANE HIP POSITION.

David M Bazett-Jones1, Tyler Tylinksi1, Jelena Krstic1, Abigail Stromquist1, Jay Sparks1.   

Abstract

BACKGROUND: An optimal position for strength testing of the hip musculature has not been identified. However, sagittal plane hip position during testing has been shown to influence hip external rotation strength. HYPOTHESIS/
PURPOSE: The purpose of this study was to compare hip extension, external rotation, and abduction isometric torque at positions with differing degrees of hip flexion using a handheld dynamometer. STUDY
DESIGN: A cross-sectional laboratory study.
METHODS: Twenty-nine healthy and physically active females participated in this study. Peak isometric contractions were measured with a handheld dynamometer secured with a non-elastic strap and then converted to torque using segment lengths. Hip external rotation and extension were tested at 0°, 30°, and 90° of hip flexion. Hip abduction was tested at 0° and 30° of hip flexion and 5° of extension. Testing was randomized and counterbalanced. Repeated measures ANOVAs with Sidak's test for multiple comparisons were used for statistical analysis. Significance was set at p<0.05.
RESULTS: Significant main effects were found for hip extension (p<0.001) and external rotation (p<0.027), but not for abduction (p=0.085). Pairwise comparisons showed significant differences between all three testing positions for hip extension torque (0°v30° : p<0.001, 0°v90° : p<0.001, 30°v90°: p=0.002). Extension torque was highest in 90° of flexion (1.43 ± 0.50 Nm/kg*m) and lowest in 0° of flexion (0.83 ± 0.30 Nm/kg*m). Comparisons of hip external rotation torque tested at 0°v90° (p=0.096) and 30°v90° (p=0.080) were not significantly different but did have medium effect sizes. External rotation torque was highest in 90° of flexion (0.29 ± 0.13 Nm/kg*m).
CONCLUSIONS: Direct comparisons of torque values of hip extension and external rotation tested at different sagittal plane positions should be cautioned due to differences. Hip extension and external rotation should be measured in consistent sagittal plane positions across examiners and testing sessions. Test position will be dependent upon the goals of strength testing. LEVEL OF EVIDENCE: 2b.

Entities:  

Keywords:  Dynamometer; hip joint; isometric force; muscle strength

Year:  2017        PMID: 28900559      PMCID: PMC5534143     

Source DB:  PubMed          Journal:  Int J Sports Phys Ther        ISSN: 2159-2896


  33 in total

1.  The relationship between lower extremity injury, low back pain, and hip muscle strength in male and female collegiate athletes.

Authors:  S F Nadler; G A Malanga; M DePrince; T P Stitik; J H Feinberg
Journal:  Clin J Sport Med       Date:  2000-04       Impact factor: 3.638

2.  Understanding and preventing acl injuries: current biomechanical and epidemiologic considerations - update 2010.

Authors:  Timothy E Hewett; Kevin R Ford; Barbara J Hoogenboom; Gregory D Myer
Journal:  N Am J Sports Phys Ther       Date:  2010-12

3.  Assessment of strength, flexibility, and running mechanics in men with iliotibial band syndrome.

Authors:  Brian Noehren; Anne Schmitz; Ross Hempel; Carolyn Westlake; William Black
Journal:  J Orthop Sports Phys Ther       Date:  2014-01-22       Impact factor: 4.751

4.  Isometric hip-rotator torque production at varying degrees of hip flexion.

Authors:  Sam Johnson; Mark Hoffman
Journal:  J Sport Rehabil       Date:  2010-02       Impact factor: 1.931

5.  Persons with chronic hip joint pain exhibit reduced hip muscle strength.

Authors:  Marcie Harris-Hayes; Michael J Mueller; Shirley A Sahrmann; Nancy J Bloom; Karen Steger-May; John C Clohisy; Gretchen B Salsich
Journal:  J Orthop Sports Phys Ther       Date:  2014-10-09       Impact factor: 4.751

6.  Hip muscle activity during 3 side-lying hip-strengthening exercises in distance runners.

Authors:  Joseph M McBeth; Jennifer E Earl-Boehm; Stephen C Cobb; Wendy E Huddleston
Journal:  J Athl Train       Date:  2012 Jan-Feb       Impact factor: 2.860

7.  Influence of joint position on electromyographic and torque generation during maximal voluntary isometric contractions of the hamstrings and gluteus maximus muscles.

Authors:  T W Worrell; G Karst; D Adamczyk; R Moore; C Stanley; B Steimel; S Steimel
Journal:  J Orthop Sports Phys Ther       Date:  2001-12       Impact factor: 4.751

8.  Concentric and eccentric torque of the hip musculature in individuals with and without patellofemoral pain.

Authors:  Michelle C Boling; Darin A Padua; R Alexander Creighton
Journal:  J Athl Train       Date:  2009 Jan-Feb       Impact factor: 2.860

9.  Hip rotator strength in healthy young adults measured in hip flexion and extension by using a hand-held dynamometer.

Authors:  Nancy Bloom; Suzanne L Cornbleet
Journal:  PM R       Date:  2014-06-17       Impact factor: 2.298

10.  Hip isometric strength following knee surgery.

Authors:  J Jaramillo; T W Worrell; C D Ingersoll
Journal:  J Orthop Sports Phys Ther       Date:  1994-09       Impact factor: 4.751

View more
  3 in total

1.  THE INFLUENCE OF HIP JOINT ANGLE ON THE RATIO BETWEEN ADDUCTION AND ABDUCTION TORQUE IN EXPERIENCED, RECREATIONAL MALE ICE HOCKEY PLAYERS.

Authors:  Patrick Welsh; Scott Howitt; Samuel J Howarth
Journal:  Int J Sports Phys Ther       Date:  2020-02

Review 2.  Hamstrings force-length relationships and their implications for angle-specific joint torques: a narrative review.

Authors:  Eleftherios Kellis; Anthony J Blazevich
Journal:  BMC Sports Sci Med Rehabil       Date:  2022-09-05

3.  Dynamic changes in intramedullary pressure 72 hours after spinal cord injury.

Authors:  Xin Zhang; Chang-Bin Liu; De-Gang Yang; Chuan Qin; Xue-Chao Dong; Da-Peng Li; Chao Zhang; Yun Guo; Liang-Jie Du; Feng Gao; Ming-Liang Yang; Jian-Jun Li
Journal:  Neural Regen Res       Date:  2019-05       Impact factor: 5.135

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.