Literature DB >> 28899126

Impact of region of interest (ROI) size on the diagnostic performance of shear wave elastography in differentiating solid breast lesions.

Jin Hee Moon1, Ji-Young Hwang1, Jeong Seon Park2, Sung Hye Koh3, Sun-Young Park3.   

Abstract

Background Shear wave elastography (SWE) using a region of interest (ROI) can demonstrate the quantitative elasticity of breast lesions. Purpose To prospectively evaluate the impact of two different ROI sizes on the diagnostic performance of SWE for differentiating benign and malignant breast lesions. Material and Methods A total of 154 breast lesions were included. Two types of ROIs were investigated: one involving an approximately 2-mm diameter, small round ROIs placed over the stiffest area of the lesion, as determined by SWE (ROI-S); and another ROI drawn along the margin of the lesion using a touch pen or track ball to encompass the entire lesion (ROI-M). Maximum elasticity (Emax), mean elasticity (Emean), minimum elasticity (Emin), and standard deviation (SD) were measured for the two ROIs. The area under the receiver operating characteristic curve (AUC) as well as the sensitivity and specificity of each elasticity value were determined. Results The AUCs for ROI-S were higher than those for ROI-M when differentiating benign and malignant breast solid lesions. The Emax, Emean, Emin, and SD of the elasticity values for ROI-S were 0.865, 0.857, 0.816, and 0.849, respectively, and for ROI-M were 0.820, 0.780, 0.724, and 0.837, respectively. However, only Emax ( P = 0.0024) and Emean ( P = 0.0015) showed statistically significant differences. For ROI-S, the sensitivity and specificity of Emax were 78.8% and 84.3%, respectively, and those for Emean were 80.8% and 81.4%, respectively. Conclusion Using ROI-S with Emax and Emean has better diagnostic performance than ROI-M for differentiating between benign and malignant breast lesions.

Entities:  

Keywords:  Breast; elastography; shear wave; ultrasonography

Mesh:

Year:  2017        PMID: 28899126     DOI: 10.1177/0284185117732097

Source DB:  PubMed          Journal:  Acta Radiol        ISSN: 0284-1851            Impact factor:   1.990


  7 in total

1.  Do deep inspiration breath-holds and free-breathing affect pancreatic tissue stiffness in shear wave elastography?

Authors:  Mustafa Kaya; Enes Gürün
Journal:  Abdom Radiol (NY)       Date:  2022-05-04

2.  Added value of deep learning-based computer-aided diagnosis and shear wave elastography to b-mode ultrasound for evaluation of breast masses detected by screening ultrasound.

Authors:  Min Young Kim; Soo-Yeon Kim; Yeon Soo Kim; Eun Sil Kim; Jung Min Chang
Journal:  Medicine (Baltimore)       Date:  2021-08-06       Impact factor: 1.817

3.  The significance of dual-mode elastography in the diagnosis of breast lesions by physicians with different levels of experience.

Authors:  Sijing Huang; Xiuqin Ye; Keen Yang; Hongtian Tian; Zhimin Ding; Jing Chen; Jinfeng Xu; Fajin Dong
Journal:  Quant Imaging Med Surg       Date:  2022-02

4.  2D-shear wave elastography in the evaluation of suspicious superficial inguinal lymph nodes: Reproducibility and region of interest selection.

Authors:  Olli Lahtinen; Mika Pulkkinen; Reijo Sironen; Ritva Vanninen; Suvi Rautiainen
Journal:  PLoS One       Date:  2022-03-28       Impact factor: 3.240

5.  Simplification of 2D shear wave elastography by enlarged SWE box and multiple regions of interest in one acquisition.

Authors:  Moritz Weiher; Felix Gunnar Richtering; Yvonne Dörffel; Hans-Peter Müller
Journal:  PLoS One       Date:  2022-09-09       Impact factor: 3.752

Review 6.  The Mechanical Microenvironment in Breast Cancer.

Authors:  Stephen J P Pratt; Rachel M Lee; Stuart S Martin
Journal:  Cancers (Basel)       Date:  2020-06-03       Impact factor: 6.575

7.  The effect of regions-of-interest and elasticity modulus selection on differentiating benign and malignant cervical lymph nodes with shear wave elastography.

Authors:  Yong-Mei Sun; Hai Dong; Zong-Yan Du; Zong-Li Yang; Cheng Zhao; Jing Chong; Ping Li
Journal:  Clinics (Sao Paulo)       Date:  2020-10-26       Impact factor: 2.365

  7 in total