Literature DB >> 2889555

Pharmacokinetics and pharmacodynamics of vecuronium administered by bolus and infusion during halothane or balanced anesthesia.

C A Shanks1, M J Avram, R J Fragen, D A O'Hara.   

Abstract

Vecuronium was administered to two patient groups as a single intravenous dose, 60 micrograms/kg, combined with an infusion, 1 microgram/min/kg. Anesthesia was maintained for the first group with a halothane-nitrous oxide technique; the second group received fentanyl-barbiturate-tranquilizer-nitrous oxide. As the infusion ended, plasma vecuronium concentrations were 0.34 (+/- 0.10) microgram/ml for the halothane group and 0.32 (+/- 0.07) microgram/ml for the fentanyl group, associated with 93% (+/- 8) and 88% (+/- 10) twitch depression, respectively. Vecuronium plasma concentration-time data were combined with the simultaneous intensities of neuromuscular blockade to model the kinetic-dynamic values for each patient. For the halothane group the steady-state volume was 0.21 (+/- 0.04) L/kg, the clearance was 2.9 (+/- 0.1) ml/min/kg, and the elimination half-life was 100 (+/- 36) minutes; for the fentanyl group these were 0.20 (+/- 0.08) L/kg, 3.2 (+/- 0.1) ml/min/kg, and 84 (+/- 43) minutes, respectively. Plasma concentrations associated with 50% blockade averaged 0.2 microgram/ml for both groups. Neither the pharmacokinetics nor the pharmacodynamics of vecuronium in humans differed between these two patient groups.

Entities:  

Mesh:

Substances:

Year:  1987        PMID: 2889555     DOI: 10.1038/clpt.1987.178

Source DB:  PubMed          Journal:  Clin Pharmacol Ther        ISSN: 0009-9236            Impact factor:   6.875


  4 in total

1.  Pharmacokinetic-pharmacodynamic modeling of doxacurium: effect of input rate.

Authors:  Y Zhu; G Audibert; F Donati; F Varin
Journal:  J Pharmacokinet Biopharm       Date:  1997-02

2.  Importance of early blood sampling on vecuronium pharmacokinetic and pharmacodynamic parameters.

Authors:  J Ducharme; F Varin; D R Bevan; F Donati
Journal:  Clin Pharmacokinet       Date:  1993-06       Impact factor: 6.447

3.  Cumulation and reversal with prolonged infusions of atracurium and vecuronium.

Authors:  R J Martineau; B St-Jean; J B Kitts; M C Curran; P Lindsay; K A Hull; D R Miller
Journal:  Can J Anaesth       Date:  1992-09       Impact factor: 5.063

4.  Effect of nitrous oxide on cisatracurium infusion demands: a randomized controlled trial.

Authors:  Hanna L Illman; Heikki Mj Antila; Klaus T Olkkola
Journal:  BMC Anesthesiol       Date:  2010-08-18       Impact factor: 2.217

  4 in total