Literature DB >> 28892841

Movement of traditional fecal indicator bacteria and source-tracking targets through septic drainfields.

Hannah Billian1, Leigh-Anne Krometis2, Theresa Thompson1, Charles Hagedorn3.   

Abstract

The past three decades' data on outbreaks in the United States indicate that homes dependent on untreated groundwater (e.g. wells) for household drinking water that are also reliant on onsite treatment of household wastewater (e.g. septic systems) may be at greater risk for waterborne disease. While groundwater quality monitoring to protect public health has traditionally focused on the detection of fecal indicator bacteria, the application of emerging source tracking strategies may offer a more efficient means to identify pollution sources and effective means of remediation. This study compares the movement of common fecal indicator bacteria (E. coli and enterococci) with a chemical (optical brighteners, OB) and a molecular (Bacteroides HF183) source tracking (ST) target in small scale septic drainfield models in order to evaluate their potential utility in groundwater monitoring. Nine PVC column drainfield models received synchronized doses of primary-treated wastewater twice daily, with influent and effluent monitored bi-weekly over a 7-month period for all targets. Results indicate that E. coli and enterococci concentrations were strongly associated (Spearman's rank, p<0.05), and correlations between enterococci and optical brighteners were moderately strong. Bacteroides HF183 was significantly, but not strongly, associated with optical brighteners and both indicator bacteria (Point-biserial correlation, p<0.05), most likely due to its sporadic detection. Application of human ST marker monitoring in groundwaters at risk of contamination by human sewage is recommended, although consistent interpretation of results will rely on more detailed evaluation of HF183 incidence in source contamination waters.
Copyright © 2017 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Fecal indicator bacteria; Groundwater; Onsite wastewater treatment; Septic drainfield; Source tracking

Mesh:

Substances:

Year:  2017        PMID: 28892841     DOI: 10.1016/j.scitotenv.2017.08.131

Source DB:  PubMed          Journal:  Sci Total Environ        ISSN: 0048-9697            Impact factor:   7.963


  1 in total

1.  Characterization of Stormwater Runoff Based on Microbial Source Tracking Methods.

Authors:  Silvia Monteiro; Gaspar Queiroz; Filipa Ferreira; Ricardo Santos
Journal:  Front Microbiol       Date:  2021-06-10       Impact factor: 5.640

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.