Literature DB >> 28890304

Hemodynamic parameters that may predict false-lumen growth in type-B aortic dissection after endovascular repair: A preliminary study on long-term multiple follow-ups.

Huanming Xu1, Zhenfeng Li1, Huiwu Dong2, Yilun Zhang3, Jianyong Wei3, Paul N Watton4, Wei Guo5, Duanduan Chen6, Jiang Xiong7.   

Abstract

Thoracic endovascular aortic repair (TEVAR) is commonly applied in type-B aortic dissection. For patients with dissection affects descending aorta and extends downward to involve abdominal aorta and possibly iliac arteries, false lumen (FL) expansion might occur post-TEVAR. Predictions of dissection development may assist in medical decision on re-intervention or surgery. In this study, two patients are selected with similar morphological features at initial presentation but with different long-term FL development post-TEVAR (stable and enlarged FL). Patient-specific models are established for each of the follow-ups. Flow boundaries and computational validations are obtained from Doppler ultrasound velocimetry. By analyzing the hemodynamic parameters, the false-to-true luminal pressure difference (PDiff) and particle relative residence time (RRT) are found related to FL remodeling. It is found that (i) the position of the first FL flow entry is the watershed of negative-and-positive PDiff and, in long-term follow-ups, and the position of largest PDiff is consistent with that of the greatest increase of FL width; (ii) high RRT occurs at the FL proximal tip and similar magnitude of RRT is found in both stable and enlarged cases; (iii) comparing to the RRT at 7days post-TEVAR, an increase of RRT afterwards in short-term is found in the stable case while a slight decrease of this parameter is found in the enlarged case, indicating that the variation of RRT in short-term post-TEVAR might be potential to predict long-term FL remodeling.
Copyright © 2017 IPEM. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Aortic dissection; Endovascular procedures; Hemodynamics

Mesh:

Year:  2017        PMID: 28890304     DOI: 10.1016/j.medengphy.2017.08.011

Source DB:  PubMed          Journal:  Med Eng Phys        ISSN: 1350-4533            Impact factor:   2.242


  8 in total

1.  False lumen pressure estimation in type B aortic dissection using 4D flow cardiovascular magnetic resonance: comparisons with aortic growth.

Authors:  David Marlevi; Julio A Sotelo; Ross Grogan-Kaylor; Yunus Ahmed; Sergio Uribe; Himanshu J Patel; Elazer R Edelman; David A Nordsletten; Nicholas S Burris
Journal:  J Cardiovasc Magn Reson       Date:  2021-05-13       Impact factor: 5.364

2.  Functional Evaluation of Embedded Modular Single-Branched Stent Graft: Application to Type B Aortic Dissection With Aberrant Right Subclavian Artery.

Authors:  Xuehuan Zhang; Duanduan Chen; Mingwei Wu; Huiwu Dong; Zhengdong Wan; Heyue Jia; Shichao Liang; Jun Shao; Jun Zheng; Shangdong Xu; Jiang Xiong; Wei Guo
Journal:  Front Cardiovasc Med       Date:  2022-05-02

3.  The Necessity to Seal the Re-Entry Tears of Aortic Dissection After TEVAR: A Hemodynamic Indicator.

Authors:  Zhenfeng Li; Huanming Xu; Chlöe Harriet Armour; Yuze Guo; Jiang Xiong; Xiaoyun Xu; Duanduan Chen
Journal:  Front Bioeng Biotechnol       Date:  2022-03-31

4.  Virtual stenting with simplex mesh and mechanical contact analysis for real-time planning of thoracic endovascular aortic repair.

Authors:  Duanduan Chen; Jianyong Wei; Yiming Deng; Huanming Xu; Zhenfeng Li; Haoye Meng; Xiaofeng Han; Yonghao Wang; Jia Wan; Tianyi Yan; Jiang Xiong; Xiaoying Tang
Journal:  Theranostics       Date:  2018-11-10       Impact factor: 11.556

5.  Virtual TEVAR: Overcoming the Roadblocks of In-Silico Tools for Aortic Dissection Treatment.

Authors:  Vanessa Diaz-Zuccarini; Mirko Bonfanti; Gaia Franzetti; Stavroula Balabani
Journal:  Theranostics       Date:  2018-12-07       Impact factor: 11.556

6.  Influence of MRI-based boundary conditions on type B aortic dissection simulations in false lumen with or without abdominal aorta involvement.

Authors:  Dongting Liu; Xuan Wang; Dongliang Zhao; Zhonghua Sun; Jumatay Biekan; Zhaoying Wen; Lei Xu; Jiayi Liu
Journal:  Front Physiol       Date:  2022-09-07       Impact factor: 4.755

7.  A Combined In Vivo, In Vitro, In Silico Approach for Patient-Specific Haemodynamic Studies of Aortic Dissection.

Authors:  Mirko Bonfanti; Gaia Franzetti; Shervanthi Homer-Vanniasinkam; Vanessa Díaz-Zuccarini; Stavroula Balabani
Journal:  Ann Biomed Eng       Date:  2020-09-14       Impact factor: 3.934

8.  Association of hemodynamic factors and progressive aortic dilatation following type A aortic dissection surgical repair.

Authors:  Yu Zhu; Saeed Mirsadraee; George Asimakopoulos; Alessia Gambaro; Ulrich Rosendahl; John Pepper; Xiao Yun Xu
Journal:  Sci Rep       Date:  2021-06-01       Impact factor: 4.379

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.