Literature DB >> 28889243

A high-throughput QCM chip configuration for the study of living cells and cell-drug interactions.

Haibo Shen1,2, Tiean Zhou3,4, Jiajin Hu1,2.   

Abstract

In this study, we present a novel design of interference-free, negligible installation-induced stress, suitable for the fabrication of high-throughput quartz crystal microbalance (HQCM) chips. This novel HQCM chip configuration was fabricated using eight independent yet same-batch quartz crystal resonators within a common glass substrate with eight through-holes of diameter slightly larger than that of the quartz resonator. Each quartz resonator's rim was adhered to the inner part of the through-hole via silicone glue to form the rigid (quartz)-soft (silicone)-rigid (glass) structure (RSRS) which effectively eliminates the acoustic couplings among different resonators and largely alleviates the installation-induced stresses. The consistence of the eight resonators was verified by very similar equivalent circuit parameters and very close response slopes to liquid density and viscosity. The HQCM chip was then employed for real-time and continuous monitoring of H9C2 cardiomyoblast adhesions and viscoelastic changes induced by the treatments of two types of drugs: drugs that affect the cytoskeletons, including nocodazole, paclitaxel, and Y-27632, and drugs that affect the contractile properties of the cells: verapamil and different dosages of isoprenaline. Meanwhile, we compared the cytoskeleton affecting drug-induced viscoelastic changes of H9C2 with those of human umbilical vein endothelial cells (HUVECs). The results described here provide the first solution to fabricate HQCM chips that are free from the limitation of resonator number, installation-induced stress, and acoustic interferences among resonators, which should find wide applications in areas of cell phenotype assay, cytotoxicity test, drug evaluation and screening, etc. Graphical abstract Schematic illustration of the principle and configuration of interference-free high-throughput QCM chip to evaluate and screen drugs based on cell viscoelasticity.

Entities:  

Keywords:  Cell phenotype; Cell-drug interactions; H9C2 cardiomyoblasts; High-throughput; Quartz crystal microbalance; Viscoelasticity

Mesh:

Year:  2017        PMID: 28889243     DOI: 10.1007/s00216-017-0591-4

Source DB:  PubMed          Journal:  Anal Bioanal Chem        ISSN: 1618-2642            Impact factor:   4.142


  2 in total

1.  Quartz Crystal Microbalance with Dissipation Monitoring of Dynamic Viscoelastic Changes of Tobacco BY-2 Cells under Different Osmotic Conditions.

Authors:  Zongxing Chen; Tiean Zhou; Jiajin Hu; Haifeng Duan
Journal:  Biosensors (Basel)       Date:  2021-04-27

2.  A Quartz Crystal Microbalance Immunosensor for Stem Cell Selection and Extraction.

Authors:  Ornella Maglio; Salvatore Costanzo; Rosaria Cercola; Gerardo Zambrano; Marco Mauro; Raffaele Battaglia; Gianluca Ferrini; Flavia Nastri; Vincenzo Pavone; Angela Lombardi
Journal:  Sensors (Basel)       Date:  2017-11-28       Impact factor: 3.576

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.