Literature DB >> 28888523

Mechanical alignment technique for TKA: Are there intrinsic technical limitations?

C Rivière1, F Iranpour2, E Auvinet2, A Aframian2, K Asare2, S Harris2, J Cobb2, S Parratte3.   

Abstract

BACKGROUND: Mechanically aligned (MA) total knee arthroplasty (TKA) is affected by disappointing functional outcomes in spite of the recent improvements in surgical precision and implant designs. This might suggest the existence of intrinsic technical limitations. Our study aims to compare the prosthetic and native trochlear articular surfaces and to estimate the extent of collateral ligament imbalance, which is technically uncorrectable by collateral ligament release when TKA implants are mechanically aligned. STUDY HYPOTHESIS: Conventional MA technique generates a high rate of prosthetic overstuffing of the distal groove, distal lateral trochlear facet and distal lateral femoral condyle (Hypothesis 1), and technically uncorrectable collateral ligament imbalance (hypothesis 2)? Disregarding the distal femoral joint line obliquity (DFJLO) when performing femoral cuts explains distal lateral femoral prosthetic stuffing and uncorrectable imbalance (hypothesis 3)?
METHODS: Twenty patients underwent a conventional MA TKA. Pre-operative MRI-based 3D knee models were generated and MA TKA was simulated. Native and prosthetic trochlear articular surfaces were compared using in-house analysis software. Following the automatic determination by the planning software of the size of the extension and flexion gaps, an algorithm was applied to balance the gaps and the frequency and amplitude of technically uncorrectable knee imbalance were estimated.
RESULTS: The conventional MA technique generates a significant slight distal lateral femoral prosthetic overstuffing (mean 0.6mm, 0.8mm, 1.25mm for the most distal lateral facet point, groove, and at the most distal point of lateral femoral condyle, respectively) and a high rate of type 1 and 2 uncorrectable knee imbalance (30% and 40%, respectively). The incidence of distal lateral prosthetic overstuffing (trochlea and condyle) and uncorrectable knee imbalance were strongly to very strongly correlated with the DFJLO (r=0.53 to 0.89).
CONCLUSION: Conventional MA technique for TKA generates frequent lateral distal femoral prosthetic overstuffing and technically uncorrectable knee imbalance secondary to disregarding the DFJLO when adjusting the femoral component frontal and axial rotations, respectively. LEVEL OF EVIDENCE: level 4.
Copyright © 2017 Elsevier Masson SAS. All rights reserved.

Entities:  

Keywords:  Imbalance; Laxity; Mechanical alignment; Retinacula ligament; Stuffing; Total knee replacement; Trochlea facet

Mesh:

Year:  2017        PMID: 28888523     DOI: 10.1016/j.otsr.2017.06.017

Source DB:  PubMed          Journal:  Orthop Traumatol Surg Res        ISSN: 1877-0568            Impact factor:   2.256


  7 in total

1.  Bone resection for mechanically aligned total knee arthroplasty creates frequent gap modifications and imbalances.

Authors:  William Blakeney; Yann Beaulieu; Benjamin Puliero; Marc-Olivier Kiss; Pascal-André Vendittoli
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2019-06-14       Impact factor: 4.342

2.  An anatomo-functional implant positioning technique with robotic assistance for primary TKA allows the restoration of the native knee alignment and a natural functional ligament pattern, with a faster recovery at 6 months compared to an adjusted mechanical technique.

Authors:  Sébastien Parratte; Philippe Van Overschelde; Marc Bandi; Burak Yagmur Ozturk; Cécile Batailler
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2022-05-13       Impact factor: 4.342

3.  Wide variation in tibial slopes and trochlear angles in the arthritic knee: a CT evaluation of 4116 pre-operative knees.

Authors:  Kaushik Hazratwala; William B O'Callaghan; Shilpa Dhariwal; Matthew P R Wilkinson
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2021-09-06       Impact factor: 4.114

4.  Using a patella reduced technique while balancing a TKA results in restored physiological strain in the collateral ligaments: an ex vivo kinematic analysis.

Authors:  Ignace Ghijselings; Orcun Taylan; Hendrik Pieter Delport; Josh Slane; Hans Van den Wyngaert; Alex Demurie; Lennart Scheys
Journal:  Arch Orthop Trauma Surg       Date:  2021-07-03       Impact factor: 3.067

5.  Undercoverage of lateral trochlear resection is correlated with the tibiofemoral alignment parameters in kinematically aligned TKA: a retrospective clinical study.

Authors:  Zhiwei Wang; Liang Wen; Liang Zhang; Desi Ma; Xiang Dong; Tiebing Qu
Journal:  BMC Musculoskelet Disord       Date:  2021-02-17       Impact factor: 2.362

6.  Primary osteoarthritic knees have more varus coronal alignment of the femur compared to young non-arthritic knees in a large cohort study.

Authors:  Elliot Sappey-Marinier; Cécile Batailler; John Swan; Matthieu Malatray; Laurence Cheze; Elvire Servien; Sébastien Lustig
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2020-06-01       Impact factor: 4.114

Review 7.  The stiff total knee arthroplasty: causes, treatment modalities and results.

Authors:  E Carlos Rodríguez-Merchán
Journal:  EFORT Open Rev       Date:  2019-10-07
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.