Literature DB >> 28885735

The seating mechanics of head-neck modular tapers in vitro: Load-displacement measurements, moisture, and rate effects.

Eric S Ouellette1,2, Aarti A Shenoy1,2, Jeremy L Gilbert1,2,3.   

Abstract

The mechanically assisted crevice corrosion performance of head-neck modular tapers is a significant concern in orthopedic biomaterials. Fretting crevice corrosion processes in modular tapers are thought to be influenced by a wide array of factors including seating mechanics of the junction, hence there is a need for in vitro test methods that can assess their performance. This study presented a test method to directly measure the load-displacement seating mechanics of modular tapers and used this method to compare the seating mechanics for different tapers, moisture, seating loads and seating rates. Seating mechanics were explored whereby the instantaneous load-displacement behavior of the head seating onto the neck is captured and used to define the mechanics of seating. Two distinct taper design/material combinations were assembled wet or dry using axially applied loads (500, 1,000, 2,000, and 4,000 N) at two loading rates of 100 and 104  N/s (n = 5 for each condition) using a servohydraulic test frame. The results showed that pull-off strength scaled with seating load and ranged between 43% and 68% of seating load depending on sample and wetness. Tapers seated wet had higher pull-off strengths (2,200 ± 300 N) than those seated dry (1,800 ± 200 N, p < 0.05). Seating mechanics (load-displacement plots) varied due to sample type and due to wetness with differences in seating energy, seating stiffness, and seating displacement. These results show the detailed mechanics of seating during assembly and provide significant insight into the complex interplay of factors associated with even "ideal" seating (axial, quasistatic) loading.
© 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:1164-1172, 2018. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

Keywords:  head-neck taper junction; implant assembly; mechanics; modular orthopedic implant; taper mechanics

Mesh:

Year:  2018        PMID: 28885735     DOI: 10.1002/jor.23725

Source DB:  PubMed          Journal:  J Orthop Res        ISSN: 0736-0266            Impact factor:   3.494


  3 in total

1.  CORR Insights®: Insights into Imprinting: How Is the Phenomenon of Tribocorrosion at Head-Neck Taper Interfaces Related to Corrosion, Fretting, and Implant Design Parameters?

Authors:  Mariano Fernandez-Fairen
Journal:  Clin Orthop Relat Res       Date:  2022-05-30       Impact factor: 4.755

Review 2.  What the Surgeon Can Do to Reduce the Risk of Trunnionosis in Hip Arthroplasty: Recommendations from the Literature.

Authors:  Claude B Rieker; Peter Wahl
Journal:  Materials (Basel)       Date:  2020-04-21       Impact factor: 3.623

3.  Importance of surgical assembly technique on the engagement of 12/14 modular tapers.

Authors:  A Wade; F Webster; A R Beadling; M G Bryant
Journal:  Proc Inst Mech Eng H       Date:  2021-10-25       Impact factor: 1.617

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.