Comparison of computed tomography (CT) and contrast-enhanced ultrasound (CEUS) for the quantitative evaluation of an ablation defect following radiofrequency ablation of malignant liver lesions.

K Bruenn1, L Beyer1, M Haimerl1, B Pregler1, C Stroszczynski1, E M Jung1, P Wiggermann1.   

Abstract

OBJECTIVE: To compare contrast-enhanced computed tomography (CT) and contrast-enhanced ultrasound (CEUS) for the quantitative evaluation of an ablation defect following radiofrequency ablation of malignant liver lesions in a prospective study.
MATERIALS AND METHODS: 22 radiofrequency ablations of malignant liver tumors were performed. The ablation defects were then measured and evaluated by two independent examiners via contrast-enhanced computed tomography (CT) and contrast-enhanced ultrasound (CEUS) using a 1-5 MHz multifrequency convex ultrasound transducer (LOGIQ E9, GE) with respect to the short-axis diameter, the long-axis diameter, and the area.
RESULTS: Quantitative evaluation of ablation defects is possible with both contrast-enhanced CT and CEUS. The average long-axis diameter was 47.1 mm (±11.08;±23,5%) on CEUS and 56.48 mm (±14.14;±25,0%) on CT; the short-axis diameter was 39.72 mm (±11.14;±28,05%) on CEUS and 40.27 mm (±10.50;±26,07%) on CT; the area was 1439.82 mm2 (±678.57;±47,13%) on CEUS and 2392.68 mm2 (1147.67;±48,0%) on CT. On average, ablation defects are assessed to be larger on CT than on CEUS. A significant correlation between the modalities could not be achieved for all measurement axes.
CONCLUSION: CEUS can be used for the postinterventional detection and evaluation of ablation defects. However, these are always assessed to be larger on contrast-enhanced CT than CEUS.

Entities:  

Keywords:  CEUS; CT; HCC; RFA; ablation

Mesh:

Substances:

Year:  2017        PMID: 28885212     DOI: 10.3233/CH-179225

Source DB:  PubMed          Journal:  Clin Hemorheol Microcirc        ISSN: 1386-0291            Impact factor:   2.375


  2 in total

Review 1.  [Contrast-enhanced ultrasound (CEUS) and image fusion for procedures of liver interventions].

Authors:  E M Jung; D A Clevert
Journal:  Radiologe       Date:  2018-06       Impact factor: 0.635

2.  Clinical Value Study on Contrast-Enhanced Ultrasound Combined with Enhanced CT in Early Diagnosis of Primary Hepatic Carcinoma.

Authors:  Libo Zhang; Junyi Gu; Ya Li; Zhen Ren; Bo Zhang; Zuoren Yu
Journal:  Contrast Media Mol Imaging       Date:  2022-09-02       Impact factor: 3.009

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.