Demonstration of extended field-of-view ultrasound's potential to increase the pool of muscles for which in vivo fascicle length is measurable.

Amy N Adkins1, Patrick W Franks2, Wendy M Murray3.   

Abstract

Static, B-mode ultrasound is the most common method of measuring fascicle length in vivo. However, most forearm muscles have fascicles that are longer than the field-of-view of traditional ultrasound (T-US). As such, little work has been done to quantify in vivo forearm muscle architecture. The extended field-of-view ultrasound (EFOV-US) method, which fits together a sequence of B-mode images taken from a continuous ultrasound scan, facilitates direct measurements of longer, curved fascicles. Here, we test the validity and reliability of the EFOV-US method for obtaining fascicle lengths in the extensor carpi ulnaris (ECU). Fascicle lengths from images of the ECU captured in vivo with EFOV-US were compared to lengths from a well-established method, T-US. Images were collected in a joint posture that shortens the ECU such that entire fascicle lengths were captured within a single T-US image. Resulting measurements were not significantly different (p=0.18); a Bland-Altman test demonstrated their agreement. A novice sonographer implemented EFOV-US in a phantom and in vivo on the ECU. The novice sonographer's measurements from the ultrasound phantom indicate that the combined imaging and analysis method is valid (average error=2.2±1.3mm) and the in vivo fascicle length measurements demonstrate excellent reliability (ICC=0.97). To our knowledge, this is the first study to quantify in vivo fascicle lengths of the ECU using any method. The ability to define a muscle's architecture in vivo using EFOV-US could lead to improvements in diagnosis, model development, surgery guidance, and rehabilitation techniques. Published by Elsevier Ltd.

Entities:  

Keywords:  Fascicle length; Forearm; Muscle architecture; Skeletal muscle; Ultrasonography

Mesh:

Year:  2017        PMID: 28882331      PMCID: PMC5648603          DOI: 10.1016/j.jbiomech.2017.08.012

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  37 in total

1.  A model of the upper extremity for simulating musculoskeletal surgery and analyzing neuromuscular control.

Authors:  Katherine R S Holzbaur; Wendy M Murray; Scott L Delp
Journal:  Ann Biomed Eng       Date:  2005-06       Impact factor: 3.934

2.  Rehabilitative ultrasound imaging: understanding the technology and its applications.

Authors:  Jackie L Whittaker; Deydre S Teyhen; James M Elliott; Katy Cook; Helene M Langevin; Haldis H Dahl; Maria Stokes
Journal:  J Orthop Sports Phys Ther       Date:  2007-08       Impact factor: 4.751

Review 3.  Skeletal muscle design to meet functional demands.

Authors:  Richard L Lieber; Samuel R Ward
Journal:  Philos Trans R Soc Lond B Biol Sci       Date:  2011-05-27       Impact factor: 6.237

4.  US extended-field-of-view imaging technology.

Authors:  L Weng; A P Tirumalai; C M Lowery; L F Nock; D E Gustafson; P L Von Behren; J H Kim
Journal:  Radiology       Date:  1997-06       Impact factor: 11.105

5.  Functional bases of fiber length and angulation in muscle.

Authors:  C Gans; F de Vree
Journal:  J Morphol       Date:  1987-04       Impact factor: 1.804

Review 6.  Functional morphology of force transmission in skeletal muscle. A brief review.

Authors:  J A Trotter
Journal:  Acta Anat (Basel)       Date:  1993

Review 7.  Functional and clinical significance of skeletal muscle architecture.

Authors:  R L Lieber; J Fridén
Journal:  Muscle Nerve       Date:  2000-11       Impact factor: 3.217

8.  Intra- and intermuscular variation in human quadriceps femoris architecture assessed in vivo.

Authors:  Anthony J Blazevich; Nicholas D Gill; Shi Zhou
Journal:  J Anat       Date:  2006-09       Impact factor: 2.610

Review 9.  Reliability and validity of ultrasound measurements of muscle fascicle length and pennation in humans: a systematic review.

Authors:  Li Khim Kwah; Rafael Z Pinto; Joanna Diong; Robert D Herbert
Journal:  J Appl Physiol (1985)       Date:  2013-01-10

10.  Effect of Transducer Orientation on Errors in Ultrasound Image-Based Measurements of Human Medial Gastrocnemius Muscle Fascicle Length and Pennation.

Authors:  Bart Bolsterlee; Simon C Gandevia; Robert D Herbert
Journal:  PLoS One       Date:  2016-06-13       Impact factor: 3.240

View more
  3 in total

1.  Motor Impairment-Related Alterations in Biceps and Triceps Brachii Fascicle Lengths in Chronic Hemiparetic Stroke.

Authors:  Christa M Nelson; Wendy M Murray; Julius P A Dewald
Journal:  Neurorehabil Neural Repair       Date:  2018-08-23       Impact factor: 3.919

2.  Obtaining Quality Extended Field-of-View Ultrasound Images of Skeletal Muscle to Measure Muscle Fascicle Length.

Authors:  Amy N Adkins; Wendy M Murray
Journal:  J Vis Exp       Date:  2020-12-14       Impact factor: 1.355

3.  Serial sarcomere number is substantially decreased within the paretic biceps brachii in individuals with chronic hemiparetic stroke.

Authors:  Amy N Adkins; Julius P A Dewald; Lindsay P Garmirian; Christa M Nelson; Wendy M Murray
Journal:  Proc Natl Acad Sci U S A       Date:  2021-06-29       Impact factor: 12.779

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.