Literature DB >> 28880335

Refractive Outcomes of 20 Eyes Undergoing ICL Implantation for Correction of Hyperopic Astigmatism.

Efekan Coskunseven, Isilay Kavadarli, Onurcan Sahin, Belma Kayhan, Ioannis Pallikaris.   

Abstract

PURPOSE: To analyze 1-week, 1-month, and 12-month postoperative refractive outcomes of eyes that under-went ICL implantation to correct hyperopic astigmatism.
METHODS: The study enrolled 20 eyes of patients with an average age of 32 years (range: 21 to 40 years). The outcomes of spherical and cylindrical refraction, uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), vault, and angle parameters were evaluated 1 week, 1 month, and 12 months postoperatively.
RESULTS: The preoperative mean UDVA was 0.15 ± 0.11 (decimal) (20/133 Snellen) and increased to 0.74 ± 0.25 (20/27 Snellen) postoperatively, with a change of 0.59 (decimal) (20/33.9 Snellen) (P < .0001), which was statistically significant. The preoperative mean CDVA was 0.74 ± 0.25 (decimal) (20/27 Snellen) and increased to 0.78 ± 0.21 (20/25 Snellen), with a change of 0.03 (decimal) (20/666 Snellen) (P < .052), which was not statistically significant. The mean preoperative sphere was 6.86 ± 1.77 diopters (D) and the mean preoperative cylinder was -1.44 ± 0.88 D. The mean 12-month postoperative sphere decreased to 0.46 ± 0.89 D (P < .001) and cylinder decreased to -0.61 ± 0.46 D (P < .001), with a change of 6.40 D, both of which were statistically significant. The mean 1-month postoperative vault was 0.65 ± 0.13 mm and decreased to 0.613 ± 0.10 mm at 1 year postoperatively, with a change of 0.44 mm (P < .003). The preoperative/12-month and 1-month/12-month trabecular-iris angle (TIA), trabecular-iris space area 500 mm from the scleral spur (TISA500), and angle opening distance 500 mm from the scleral spur (AOD500) values were analyzed nasally, temporally, and inferiorly. All differences were statistically significant between preoperative/12-month analysis. The only differences between 1- and 12-month analysis were on TISA500 inferior (P < .002) and AOD500 nasal (0.031) values.
CONCLUSIONS: ICL hyperopic toric implantation is a safe method and provides stable refractive outcomes in patients with high hyperopia (up to 10.00 D) and astigmatism (up to 6.00 D). [J Refract Surg. 2017;33(9):604-609.]. Copyright 2017, SLACK Incorporated.

Entities:  

Mesh:

Year:  2017        PMID: 28880335     DOI: 10.3928/1081597X-20170504-06

Source DB:  PubMed          Journal:  J Refract Surg        ISSN: 1081-597X            Impact factor:   3.573


  4 in total

1.  The effects of implantable collamer lens implantation on higher order aberrations.

Authors:  Belma Kayhan; Efekan Coskunseven; Onurcan Sahin; Ioannis Pallikaris
Journal:  Int J Ophthalmol       Date:  2019-12-18       Impact factor: 1.779

Review 2.  Analysis of perioperative problems related to intraocular Implantable Collamer Lens (ICL) implantation.

Authors:  Hao Zhang; Rui Gong; Xiaolan Zhang; Yingping Deng
Journal:  Int Ophthalmol       Date:  2022-06-22       Impact factor: 2.029

3.  Safety and visual outcomes following posterior chamber phakic intraocular lens bilensectomy.

Authors:  Veronica Vargas; Jorge L Alió; Rafael I Barraquer; Justin Christopher D' Antin; Cristina García; Francisco Duch; Joan Balgos; Jorge L Alió Del Barrio
Journal:  Eye Vis (Lond)       Date:  2020-07-01

4.  Evaluation of the anterior chamber angle by anterior segment optical coherence tomography after implantable phakic contact lens implantation in myopic eyes.

Authors:  Mohamed Salah El-Din Mahmoud; Asmaa Anwar Mohamed; Hosny Ahmed Zein
Journal:  Int Ophthalmol       Date:  2022-03-04       Impact factor: 2.029

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.