Literature DB >> 28878514

Traumatic cervical epidural hematoma due to fusion mass fracture following elective rod removal.

Dominic T Kleinhenz1,2, Adam E M Eltorai2, Stephen Huo3,2, Alan H Daniels3,2.   

Abstract

Many studies have examined complications associated with spinal instrumentation, however, few have analyzed complications associated with removal. In this case report, we outline the course of a patient who presented with cervical epidural hematoma secondary to fusion mass fracture five years after removal of spinal hardware.

Entities:  

Keywords:  Cervical fracture; Epidural hematoma; Fusion mass fracture; Hardware removal; Spinal instrumentation

Year:  2017        PMID: 28878514      PMCID: PMC5574815          DOI: 10.1016/j.jor.2017.07.014

Source DB:  PubMed          Journal:  J Orthop        ISSN: 0972-978X


  7 in total

1.  Biomechanical study of thoracolumbar junction fixation devices with different diameter dual-rod systems.

Authors:  Ung-Kyu Chang; Jesse Lim; Daniel H Kim
Journal:  J Neurosurg Spine       Date:  2006-03

2.  Loss of coronal correction following instrumentation removal in adolescent idiopathic scoliosis.

Authors:  Benjamin K Potter; Kevin L Kirk; Suken A Shah; Timothy R Kuklo
Journal:  Spine (Phila Pa 1976)       Date:  2006-01-01       Impact factor: 3.468

3.  Spinal disorders at the cervicothoracic junction.

Authors:  H S An; A Vaccaro; J M Cotler; S Lin
Journal:  Spine (Phila Pa 1976)       Date:  1994-11-15       Impact factor: 3.468

4.  Fracture of fusion mass after hardware removal in patients with high sagittal imbalance.

Authors:  Cara L Sedney; Scott D Daffner; Jared J Stefanko; Hesham Abdelfattah; Sanford E Emery; John C France
Journal:  J Neurosurg Spine       Date:  2015-12-18

5.  Construct Type and Risk Factors for Pseudarthrosis at the Cervicothoracic Junction.

Authors:  Justin S Yang; Jacob M Buchowski; Vivek Verma
Journal:  Spine (Phila Pa 1976)       Date:  2015-06-01       Impact factor: 3.468

6.  Loss of sagittal plane correction after removal of spinal implants.

Authors:  J E Deckey; C Court; D S Bradford
Journal:  Spine (Phila Pa 1976)       Date:  2000-10-01       Impact factor: 3.468

7.  Thoracolumbar burst fracture. A biomechanical investigation of its multidirectional flexibility.

Authors:  M M Panjabi; T R Oxland; R M Lin; T W McGowen
Journal:  Spine (Phila Pa 1976)       Date:  1994-03-01       Impact factor: 3.468

  7 in total
  1 in total

1.  Traumatic and non-traumatic spinal cord injury: Demographic characteristics, neurological and functional outcomes. A 7-year single centre experience.

Authors:  B Alito; V Filardi; F Famà; D Bruschetta; C Ruggeri; G Basile; L Stancanelli; C D'Amico; S Bianconi; A Tisano
Journal:  J Orthop       Date:  2021-11-20
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.