| Literature DB >> 28878470 |
Ashfaq Ahmad1, Mohammad A Mohseni Bandpei1,2, S Amir Gilani3, Arooj Munawar4, Ishaq Ahmed4, Fahad Tanveer5.
Abstract
[Purpose] The purpose of this study was to assess intra-rater and inter-rater reliability of musculoskeletal ultrasound (MSKUS) as a tool to measure supraspinatus tendon thickness in healthy subjects.Entities:
Keywords: Musculoskeletal ultrasound; Reliability; Supraspinatus tendon
Year: 2017 PMID: 28878470 PMCID: PMC5574356 DOI: 10.1589/jpts.29.1394
Source DB: PubMed Journal: J Phys Ther Sci ISSN: 0915-5287
Characteristics of the subjects (N=20)
| Characteristic | Mean ± SD | Range |
|---|---|---|
| Age (years) | 37.3 ± 18.1 | 30–49 |
| Gender | Male | 12 |
| Female | 8 | |
| Height (cm) | 173.2 ± 11.3 | 162–184 |
| Weight (kg) | 72.3 ± 12.2 | 60–84 |
| BMI | 22.1 ± 2.4 | 18–25 |
N: total number of participants; BMI: body mass index; SD: standard deviation
Measured values for supraspinatus tendon thickness (mm)
| Subjects | Rater 1 | Rater 2 | ||||
|---|---|---|---|---|---|---|
| Session 1 | Session 2 | Session 3 | Session 1 | Session 2 | Session 3 | |
| 1 | 3.9 | 3.7 | 4.3 | 4.1 | 4.2 | 4.5 |
| 2 | 5.0 | 4.6 | 4.5 | 4.8 | 5.1 | 5.3 |
| 3 | 5.6 | 6.0 | 5.3 | 5.3 | 5.6 | 5.7 |
| 4 | 5.7 | 5.3 | 5.3 | 5.5 | 5.8 | 5.8 |
| 5 | 3.3 | 3.8 | 3.5 | 3.5 | 3.2 | 3.1 |
| 6 | 4.6 | 5.0 | 5.0 | 4.8 | 4.4 | 4.2 |
| 7 | 5.3 | 5.9 | 5.7 | 5.5 | 5.2 | 5.0 |
| 8 | 4.3 | 4.0 | 3.8 | 4.5 | 4.1 | 4.1 |
| 9 | 5.1 | 5.5 | 5.4 | 5.2 | 4.9 | 4.9 |
| 10 | 6.2 | 6.0 | 6.5 | 6.0 | 5.7 | 5.6 |
| 11 | 5.8 | 5.4 | 5.4 | 5.6 | 5.3 | 5.2 |
| 12 | 6.2 | 6.6 | 6.6 | 6.4 | 6.1 | 6.1 |
| 13 | 5.3 | 4.8 | 5.7 | 5.5 | 5.3 | 5.1 |
| 14 | 5.5 | 5.8 | 5.9 | 5.7 | 5.5 | 5.4 |
| 15 | 5.8 | 6.1 | 6.2 | 6.0 | 5.7 | 5.7 |
| 16 | 4.7 | 4.4 | 4.3 | 4.9 | 4.6 | 5.3 |
| 17 | 6.3 | 5.9 | 6.7 | 6.5 | 6.3 | 6.3 |
| 18 | 5.3 | 5.5 | 5.6 | 5.1 | 5.4 | 5.0 |
| 19 | 4.3 | 4.1 | 4.8 | 4.1 | 4.4 | 4.5 |
| 20 | 4.7 | 4.5 | 4.3 | 4.9 | 4.6 | 4.5 |
Mean ± SD and ICC(2,1) for within day and between days intra-rater reliability measures of supraspinatus tendon thickness
| Variable | Reliability | Mean ± SD | ICC (95% CI) | SEM (deg) | |
|---|---|---|---|---|---|
| Supraspinatus tendon thickness (mm) | Within day | R1 | 5.14 ± 0.83 | 0.89 (0.76−0.95) | 0.18 |
| R2 | 5.14 ± 0.83 | 0.93 (0.85−0.97) | 0.18 | ||
| Between days | R1 | 5.19 ± 0.86 | 0.90 (0.77−0.96) | 0.38 | |
| R2 | 5.13 ± 0.76 | 0.88 (0.72−0.95) | 0.17 | ||
SD: standard deviation; ICC (2, 1): Intraclass Correlation Coefficient; SEM: standard error of measurement; deg: degrees; R1: Rater one; R2: Rater two; CI: confidence Interval
Mean ± SD and ICC (2,2) for within day and between days inter-rater reliability measures of supraspinatus tendon thickness
| Variable | Reliability | Mean ± SD | ICC (95% CI) | SEM (deg) |
|---|---|---|---|---|
| Supraspinatus tendon thickness (mm) | Within day | 5.17 ± 0.78 | 0.98 (0.95–0.99) | 0.17 |
| Between days | 5.10 ± 0.78 | 0.95 (0.88−0.98) | 0.17 |
SD: standard deviation; ICC (2, 2): Intraclass Correlation Coefficient; SEM: standard error of measurement; deg: degrees; CI: confidence interval