Kensuke Shimada1, Tomo Onishi2, Yoshiko Ogawa1, Junichiro Yamauchi3, Shigeo Kawada1. 1. Department of Sport and Medical Science, Faculty of Medical Technology, Teikyo University, Japan. 2. Teikyo University Institute of Sports Science and Medicine, Japan. 3. Graduate School of Human Health Sciences, Tokyo Metropolitan University, Japan.
Abstract
[Purpose] This study aimed to develop a simple, inexpensive, and accurate method for measuring the strength of shoulder flexion (Experiment 1) and evaluate the bilateral force deficit in shoulder flexion (Experiment 2) in healthy subjects. [Subjects and Methods] In Experiment 1, maximal voluntary contractions (MVCs) in isometric shoulder flexion were measured on both sides using an isometric dynamometer (ID) and a hand-grip dynamometer (HGD), as an alternative dynamometer, in six subjects. In Experiment 2, bilateral force deficit was evaluated using HGD in 21 subjects who performed unilateral and bilateral MVCs in isometric flexions of the shoulder. The peak value of electromyography (PVE) in the lateral head of the biceps brachii and anterior deltoid was measured during MVCs. [Results] In Experiment 1, ID and HGD showed almost similar coefficients of variation. A strong positive correlation was found between the values obtained using the two methods. In Experiment 2, the bilateral force deficit in shoulder flexion associated with a reduced PVE (‒10.9%) was found in 85.7% of subjects. [Conclusion] The reproducibility of measurements was similar between ID and HGD. HGD could evaluate the bilateral force deficit in shoulder flexion and is a practical tool for measuring shoulder strength.
[Purpose] This study aimed to develop a simple, inexpensive, and accurate method for measuring the strength of shoulder flexion (Experiment 1) and evaluate the bilateral force deficit in shoulder flexion (Experiment 2) in healthy subjects. [Subjects and Methods] In Experiment 1, maximal voluntary contractions (MVCs) in isometric shoulder flexion were measured on both sides using an isometric dynamometer (ID) and a hand-grip dynamometer (HGD), as an alternative dynamometer, in six subjects. In Experiment 2, bilateral force deficit was evaluated using HGD in 21 subjects who performed unilateral and bilateral MVCs in isometric flexions of the shoulder. The peak value of electromyography (PVE) in the lateral head of the biceps brachii and anterior deltoid was measured during MVCs. [Results] In Experiment 1, ID and HGD showed almost similar coefficients of variation. A strong positive correlation was found between the values obtained using the two methods. In Experiment 2, the bilateral force deficit in shoulder flexion associated with a reduced PVE (‒10.9%) was found in 85.7% of subjects. [Conclusion] The reproducibility of measurements was similar between ID and HGD. HGD could evaluate the bilateral force deficit in shoulder flexion and is a practical tool for measuring shoulder strength.
In the rehabilitation field, the evaluation of muscle strength is important. Specific
isometric and/or isokinetic dynamometers (IDs) such as Biodex and Cybex are used for the
evaluation, and the evaluation using these is employed as the gold standard. However,
because these dynamometers are extensive and too large, use in sports-medicine practices are
limited1). In recent years, the validity
and reliability of simple handheld dynamometers have been investigated for alternative
measurements of muscle strength2, 3). Significant correlation coefficients
between the values obtained using handheld dynamometers and isometric dynamometers have been
reported2, 4,
5).When handheld dynamometers are alternatively used to evaluate muscle strength, most studies
measure a lower limb muscle strength. In this context, there are limited data reporting
analyses of muscle strength in upper limbs, especially in shoulders. Shoulder injuries often
occur at work and in sports6).
Particularly, for athletes, recovery of both shoulder muscle strength and function are
important in the rehabilitation program. Assessment of bilateral force deficit is one of the
methods used to evaluate muscle function in the practical situation. Bilateral force deficit
is a reduction in the maximal voluntary strength induced by simultaneous bilateral muscle
contractions compared with that induced by the sum of right and left unilateral
contractions7,8,9). Bilateral force deficit is
common in untrained individuals, whereas it is not found in competitive oarsmen10), implying that an habitual bilateral
training influences to the bilateral force deficit. In the rehabilitation of athletes who
perform sports using bilateral limbs simultaneously, assessment of bilateral force deficit
is one of the important methods for evaluating muscle function. The validity, reliability,
mobility, and low cost of equipment for the evaluation of muscle strength are considered
highly advantageous in the rehabilitation field. Therefore, the aims of this investigation
were to develop a simple, inexpensive, and accurate method of measuring muscle strength
using a hand-grip dynamometer (HGD) (one of the inexpensive handheld dynamometers) as an
alternative dynamometer (Experiment 1) and to determine whether HGD is able to evaluate
bilateral force deficit in shoulder flexion (Experiment 2).
SUBJECTS AND METHODS
All experimental procedures were performed in accordance with the guidelines of the
Declaration of Helsinki and were approved by the Ethics Committee of the Teikyo University
(approval no. 16-031). The subjects were informed regarding the experimental procedures,
risks, and purpose of the study and signed an informed consent prior to undergoing the
experimental procedures. Six healthy adult male volunteers (age, 21.5 ± 0.8 years; height,
174.6 ± 5.1 cm; body weight, 68.3 ± 6.9 kg) with no known neuromuscular disorders or
functional limitations participated in Experiment 1. The data of muscle strength obtained
using IDs are employed as a reference in research field2). Therefore, to evaluate the validity and reproducibility of the
subjects’ strength of shoulder flexion with a digital HGD (TKK5401, Takei Scientific
Instruments Co., Ltd., Niigata, Japan), correlation analysis was performed between HGD and
ID (Cybex Norm, Medica Co., Ltd., Fukuoka, Japan). The subjects were randomly divided into
two groups. In three subjects we measured the maximal voluntary contractions (MVCs) of the
right shoulder flexion during maximal isometric contractions for 3 s/repetition at 90° of
shoulder flexion, at 0° of elbow (full extension of elbow), and neutral angle (0°) of the
wrist using ID (Fig. 1A), and then the MVC of their left shoulder flexion using HGD was measured in a posture
same as that for ID measurement. After a minimum 24-h interval, we measured the MVCs of the
same subjects’ left shoulder flexion using ID and right shoulder flexion using HGD (Fig. 1B). We also measured the MVC of the other three
subjects’ shoulder flexion using a protocol same as that for the first group in the reverse
order. The subjects were tested in a gravity-neutral, supine position. For HGD measurement,
a leather belt was hung between the center of the HGD grip and the processus styloideus
radii (Fig. 1B). To calculate the torque of the
shoulder flexion using HGD, the length from the acromion to the processus styloideus radii
was measured in each subject. To evaluate the reproducibility of both HGD and ID, each
measurement was repeated three times at a 10-min interval between each repetition, and the
respective coefficients of variation (CVs) were calculated. To analyze the correlation of
torque of the shoulder flexion between ID and HGD, the mean torque values of each of the
three repetitions in each apparatus were used as the representative values for each
apparatus.
Fig. 1.
Measurement methods in ID (A) and HGD (B)
Measurement methods in ID (A) and HGD (B)Twenty-one healthy subjects (males, n=17; age, 20.8 ± 1.3 years; females, n=4; age, 18.8 ±
0.5 years) with no known neuromuscular disorders or functional limitations participated in
Experiment 2 to investigate if bilateral force deficit in shoulder flexion could be detected
using HGD. The subjects were seated on a chair with their back straight along with a
backrest to fix their trunk during the measurements (Fig.
2). They were randomly divided into two groups. In 11 subjects, we measured the MVC of
isometric bilateral strength of their shoulder flexion. After a 10-min interval, the right
and left unilateral MVCs of shoulder flexion were measured. The same MVC measurements were
performed in the other 10 subjects but in the reverse order. The subjects performed one
repetition of maximal shoulder flexion for 3 s at 90° of shoulder flexion, at 0° of elbow
flexion, and at 90° of wrist pronation. For HGD measurement, a leather belt was hung between
the center of HGD grip and processus styloideus radii. Because the limitation of detection
for the HGD used in this study was ≥5.0 kg, measurements for the subjects with strengths of
<5.0 kg were obtained using the leather belt hung from their elbow (two males and three
females). The data from each of the right and left unilateral and bilateral tasks were used
to calculate the bilateral indices (BIs). The BI was defined as follows: BI=bilateral/(left
unilateral + right unilateral) in HGD strength. BIs >1.0 indicated that the bilateral
values were greater than the unilateral values (bilateral force facilitation), whereas
BIs<1.0 indicated that the sum of the right and left bilateral values was less than that
of the unilateral values (bilateral force deficit). One week after the first assessment of
bilateral force deficit, the subjects who were found to have a bilateral force deficit were
asked to visit to the laboratory, where electromyography (EMG) signals during bilateral and
unilateral MVCs were recorded from the biceps brachii and anterior of deltoideus. EMG
signals were recorded from the side that was found to have a larger BI among the right and
left sides (ME6400; Nihon Medix, Tokyo, Japan). Bipolar surface electrodes (Ambu Blue Sensor
M-00-S/50; Nihon Medix) were placed over the belly of the muscles with a constant
interelectrode distance of 30 mm. The EMG data were band-pass filtered at frequencies
between 8 and 500 Hz, and sampled at 1,000 Hz. The obtained values were averaged per 10 ms
to exclude artifactual influences; subsequently, the peak values of electromyography (PVE)
in the lateral head of biceps brachii and anterior deltoid were obtained.
Fig. 2.
Measurement method while sitting
Measurement method while sittingAll values were expressed as mean ± standard deviation (SD). In Experiment 1, correlation
analyses were used to compare the values of ID and HGD using the Pearson’s product moment
correlation coefficient. The differences between the values of ID and HGD were examined
using the paired Student’s t-test. In Experiment 2, the differences between the values of
bilateral and unilateral measurements were examined using the paired student’s t-test. The
BIs were examined using the one-sample t-test. To analyze PVE the relative values (bilateral
PVE/unilateral PVE) were examined using the one-sample t-test. A probability (p) value of
<0.05 was considered to be statistically significant. Statistical analyses were performed
using a statistical software (IBM SPSS Statics 23, IBM Japan).
RESULTS
ID and HGD measurements showed almost similar CVs (Table 1). The values of shoulder flexion torque using HGD were significantly higher
than those using ID (p<0.01) (Table 1). ID
and HGD measurements were significantly correlated (p<0.01) with correlation coefficients
of 0.775 (95% CI, 0.364‒0.934). Bilateral force deficit was detected in 18 out of 21 (85.7%)
subjects. The mean BI was 0.884 (p<0.01) (Table
2). Although each PVE in the lateral head of the biceps brachii or anterior
deltoid did not significantly decrease during bilateral MVCs compared to that during
unilateral MVCs, the mean value of PVE in the lateral head of the biceps brachii and
anterior deltoid during bilateral contractions was significantly lower (p<0.05) than that
during unilateral contractions (Table 2).
Table 1.
Coefficients of variation (CVs) in ID and HGD, and the torque of ID and
HGD
Bilateral index (BI) and the relative peak values of electromyography (PVE) in
bilateral muscle contraction
BI ± SD
0.884 ± 0.050**
95% CI
0.859–0.909
relative PVE ± SD
95% CI
Shoulder
0.925 ± 0.207
0.822–1.028
Biceps brachii
0.857 ± 0.298
0.709–1.005
(Shoulder + Biceps brachii)/2
0.891 ± 0.200*
0.792–0.990
The relative PVE was calculated as follows: (PVE in bilateral contraction/PVE in
unilateral contraction)
*p<0.05, **p<0.01
*p<0.01ID: isometric dynamometer; HGD: hand-grip dynamometer; 95% CI: 95% confidence
intervalThe relative PVE was calculated as follows: (PVE in bilateral contraction/PVE in
unilateral contraction)*p<0.05, **p<0.01
DISCUSSION
The results of the present study showed no significant differences in CV between ID and
HGD. In addition, we found a significant correlation between ID and HGD. Therefore, we
believe that HGD is acceptable for use in evaluating the strength of shoulder flexion.
However, a few points should be considered. In this study, HGD showed a significantly higher
torque (26.1%) compared with ID. During the measurement of shoulder flexion torque in this
study, the researchers had to pull HGD toward the opposite direction against the direction
of shoulder flexion to maintain a constant angle of shoulder flexion; thus the muscles
involved in shoulder flexion might have been forced to eccentrically contract. This
eccentric muscle contraction may have caused the generation of a large amount of force. It
has been reported that eccentric muscle contractions generate greater strength than
isometric and concentric muscle contractions11, 12). Although evaluations of time course
changes in the muscle strength of individuals using HGD are thought to be fully accessible
in the rehabilitation field, attention must be paid in the comparisons of the absolute
values between the different measurement equipment.It is well known that a decrease in the maximal voluntary strength is induced by
simultaneous bilateral exertion and not with unilateral exertion7, 8). This phenomenon is
known as bilateral force deficit. It is also known that all exertions do not necessarily
show the same extent of bilateral force deficit. Exertions using smaller muscles such as
hand grip and finger flexion still show bilateral force deficit to a smaller extent compared
with exertions using larger muscles such as arm flexion and knee extension7, 13,14,15).
Because shoulder and biceps brachii muscles are larger than finger muscles, we predicted
that the detection of bilateral force deficit is possible in shoulder flexion. Although
bilateral force deficit was not observed in some of the subjects (14.7%), it was detected in
most of the subjects (BI=0.884). A study has shown that healthy subjects who have not
experienced any bilateral training of the upper extremities show bilateral force deficit in
shoulder flexion with a certain degree of variation, implying that some subjects do not show
the bilateral force deficit13). Our study
also detected bilateral force deficit in shoulder flexion in majority of the participants.
Because the assessment of bilateral force deficit is one of the important methods for
evaluating muscle function, HGD is a useful measuring tool as an alternative dynamometer in
the rehabilitation field.Bilateral force deficit is considered to be induced by a neural limitation during bilateral
exertions16, 17). It has been reported that reduced electromyographic activation is
associated with reduced muscle strength under bilateral knee extensions18). In this study, EMG data were obtained from shoulder and
biceps brachii muscles because anatomically, these muscles were considered to be mainly
activated during shoulder flexion. Our EMG data showed that significant reductions of PVE
were not observed in the shoulder and biceps brachii muscles individually under bilateral
contractions compared to those under unilateral contractions. However, the mean value of the
two muscles showed significant reductions under bilateral contractions compared with those
under unilateral contractions, implying that bilateral force deficit in an exertion using
multiple muscles is not necessarily induced evenly in all muscles related to the
exertion.Because commercially available HGDs are used to measure the hand-grip strength in children
and adults, much lower strength than predicted hand-grip strength in children is not
detected. The limitation of detection for the HGD used in this study was ≥5.0 kg. A part of
the subjects in this study was not over 5.0 kg when a leather belt was hung between the
center of HGD grip and processus styloideus radii. However, measurements for the subjects
with strengths of <5.0 kg were obtained using the leather belt hung from their elbow.
Therefore, it is possible to measure low strength by moving the hanging point of the leather
belt to more proximal point, e.g. from processus styloideus radii to elbow.In conclusion, HGD is a valid, reproducible, portable, and cost-effective tool as an
alternative dynamometer that is practical and useful for the assessment of shoulder strength
and function in the rehabilitation field. Using this HGD method, bilateral force deficit in
shoulder flexion was found. Because the assessment of bilateral force deficit is one of the
important methods for evaluating sports specific muscle function, HGD is an alternative
measuring tool in the rehabilitation field.