Literature DB >> 28870745

Failed Two-Stage Exchange: Factors Leading to Unachievable Endoprosthetic Reconstruction After Multiple Revision Surgeries.

Kevin Staats1, Christoph Boehler1, Stephan Frenzel2, Stephan E Puchner1, Johannes Holinka1, Reinhard Windhager1.   

Abstract

BACKGROUND: Information about the outcome after failed 2-stage exchange is scarce. The aim of this study is to determine possible influencing factors leading to multiple revisions, resulting in a failed endoprosthetic joint reconstruction.
METHODS: Medical records of patients (15 hip and 29 knee joints) who had undergone additional revision surgeries due to a failed 2-stage exchange were reviewed concerning infection parameters, number and type of procedure(s), current state of the revised joint, and whether failure of endoprosthetic reconstruction had occurred.
RESULTS: Endoprosthetic reconstruction was achieved in 52.3% (n = 23) of the patients. About 36.4% (n = 16) of patients successfully reached the second stage of the initial 2-stage exchange. Half of the patients (n = 22) had to undergo spacer exchange in the initial interstage period. Five or more revision surgeries significantly increased the odds of failure of endoprosthetic reconstruction compared to patients with <5 revision surgeries (odds ratio 4.98, 95% confidence interval 1.34-18.4, P = .016). Patients with initial culture-negative revision surgery showed no significant differences in the odds of failure of endoprosthetic reconstruction (odds ratio 0.69, 95% confidence interval 0.20-2.43, P = .567).
CONCLUSION: Patients undergoing re-revision surgery due to a failed 2-stage exchange are very likely to ultimately experience a failed endoprosthetic reconstruction. The identification of the underlying pathogen does not influence the likelihood of a better outcome in terms of a successful endoprosthetic reconstruction.
Copyright © 2017 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  2-stage; arthroplasty; failed 2-stage; infection; multiple revisions

Mesh:

Year:  2017        PMID: 28870745     DOI: 10.1016/j.arth.2017.07.049

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  2 in total

1.  Long Term Results of a Rotating Hinge Total Knee Prosthesis With Carbon-Fiber Reinforced Poly-Ether-Ether-Ketone (CFR-PEEK) as Bearing Material.

Authors:  Klemens Vertesich; Kevin Staats; Christoph Böhler; Richard Koza; Richard Lass; Alexander Giurea
Journal:  Front Bioeng Biotechnol       Date:  2022-03-04

2.  Distal femoral reconstruction following failed total knee arthroplasty is accompanied with risk for complication and reduced joint function.

Authors:  Klemens Vertesich; Stephan E Puchner; Kevin Staats; Markus Schreiner; Christian Hipfl; Bernd Kubista; Johannes Holinka; Reinhard Windhager
Journal:  BMC Musculoskelet Disord       Date:  2019-01-31       Impact factor: 2.362

  2 in total