| Literature DB >> 28870061 |
Mitsuhiko Takahashi1,2, Ryosuke Sato2, Kenji Kondo2, Koichi Sairyo2.
Abstract
PURPOSE: The aim of this study was to elucidate whether intrasynovial corticosteroid injections for trigger digit reduced the volume of the tendon and pulley on high-resolution ultrasonography.Entities:
Keywords: Adrenal cortex hormones; Tendons; Trigger finger disorder; Ultrasound
Year: 2017 PMID: 28870061 PMCID: PMC5885478 DOI: 10.14366/usg.17038
Source DB: PubMed Journal: Ultrasonography ISSN: 2288-5919
Fig. 1.A 70-year-old man with grade III trigger finger at the left 4th finger.
A. Longitudinal view on ultrasonography over the palmar aspect of the affected metacarpophalangeal joint refers the positional relation of the axial images. Dotted lines indicate the corresponding axial planes shown in C and D. Scale bar=10 mm. B. The same view with A shows the A1 and A2 pulleys (shaded area) over the tendon (T), volar plate (V), metacarpal head (M) and proximal phalanx (P). C, D. Consecutive axial images show the distal, less thick pulley (C) and the thickest pulley (D). Hypoechoic fluid distension was maximal at the level of D, E. Ultrasonography at the same level as D conducted 26 days after the injection shows decreased thickness of the tendon (from 3.78 to 3.41 mm), cross-sectional area of the tendon (from 18.52 to 16.15 mm2), and thickness of the pulley (from 0.922 to 0.533 mm), but no decrease in the transverse diameter of the tendon (from 5.59 to 5.81 mm) in this case.
Fig. 2.Axial view for the measurements.
A-D. An axial view on ultrasonography is used in this study to measure four parameters: the transverse diameter of the tendon (A, dotted line), the thickness of the tendon (B, dotted line), the cross-sectional area of the tendon (C, dotted line), and the thickness of the pulley (D, arrows). The tendon shows a hyperechoic fibrillar pattern, while hypoechoic fluid distension is maximal.
Ultrasound parameters measured by the two independent raters before and after the injection
| Parameter | Before injection | After injection | P-value |
|---|---|---|---|
| Transverse diameter of the tendon (mm) | |||
| Rater 1 | 6.29±0.20 | 5.93±0.20 | 0.011 |
| Rater 2 | 6.27±0.20 | 5.74±0.19 | 0.009 |
| Thickness of the tendon (mm) | |||
| Rater 1 | 4.52±0.16 | 4.38±0.12 | 0.119 |
| Rater 2 | 4.72±0.17 | 4.53±0.15 | 0.072 |
| Cross-sectional area of the tendon (mm2) | |||
| Rater 1 | 21.67±1.34 | 19.01±1.15 | 0.020 |
| Rater 2 | 22.34±1.44 | 19.70±1.28 | 0.016 |
| Thickness of the pulley (mm) | |||
| Rater 1 | 1.12±0.10 | 0.70±0.05 | 0.002 |
| Rater 2 | 1.06±0.09 | 0.67±0.04 | <0.001 |