Literature DB >> 28869636

Structure and corrosion resistance of Co-Cr-Mo alloy used in Birmingham Hip Resurfacing system.

Ewa Dobruchowska1, Monika Paziewska1, Krzysztof Przybyl1, Kazimierz Reszka1.   

Abstract

PURPOSE: The endoprostheses made of cobalt-chromium-molybdenum (Co-Cr-Mo) alloys belong to the group of the most popular metallic implants used for reconstruction of hip joints. For such biomaterials, the primary goal is a correct and long-term functioning in the aggressive environment of body fluids. Therefore, the purpose of this study was to examine both the morphology and the corrosion resistance of implants made of the cobalt alloy used in Birmingham Hip Resurfacing (BHR) system (Smith & Nephew). For comparative purposes, the electrochemical studies were done for the nitrided stainless steel - Orthinox.
METHODS: Observations of the microstructure of the material under investigation were performed by means of the optical metallographic microscope and the scanning electron microscope. Furthermore, Energy Dispersive X-ray Spectroscopy was used to analyse the chemical composition of the endoprosthesis. Characterisation and evaluation of electrochemical corrosion resistance of the selected alloys were performed by potentiodynamic polarisation tests.
RESULTS: The structural studies confirmed that Co-Cr-Mo (BHR system) is characterised by a typical dendritic microstructure with carbide precipitates, mainly M23C6, within the interdendritic areas. The results of the polarisation measurements showed that the cobalt alloy investigated exhibits lower corrosion potential than Orthinox in the utilised environments (3% NaCl, simulated body fluid - Hank's Body Fluid).
CONCLUSIONS: However, the high passivation ability of the Co-Cr-Mo alloy, as well as its resistance to the initiation and propagation of localised corrosion processes, indicate that this material is significantly more appropriate for long-term implants.

Entities:  

Mesh:

Substances:

Year:  2017        PMID: 28869636

Source DB:  PubMed          Journal:  Acta Bioeng Biomech        ISSN: 1509-409X            Impact factor:   1.073


  3 in total

1.  Recycling of Technogenic CoCrMo Alloy by Electron Beam Melting.

Authors:  Katia Vutova; Vladislava Stefanova; Vania Vassileva; Stela Atanasova-Vladimirova
Journal:  Materials (Basel)       Date:  2022-06-12       Impact factor: 3.748

2.  Total Talar Replacement With Custom-Made Vitallium Prosthesis for Talar Avascular Necrosis.

Authors:  Wenbin Luo; Hanyang Zhang; Qing Han; Zhaoyan Li; Zhuan Zhong; Guoliang Jia; Yuxuan Liu; Fei Chang; Jincheng Wang
Journal:  Front Bioeng Biotechnol       Date:  2022-05-20

3.  Metal-Metal Hip Prosthesis and Kidney Cancer: Assumed Role of Chromium and Cobalt Overload.

Authors:  Valentin Massardier; Mickaël Catinon; Ana-Maria Trunfio-Sfarghiu; Jacques Hubert; Michel Vincent
Journal:  Am J Case Rep       Date:  2020-09-03
  3 in total