Literature DB >> 28869455

Influence of Ultrasound Microbubbles on kidney oxygen tension.

P Lamby1, L Prantl1, A Krüger-Genge2, R P Franke3, E M Jung4, F Jung2.   

Abstract

Ultrasound contrast agents (USCA) allows the dynamic detection of blood flow of both the macro and microvasculature. An obvious prerequisite for USCAs is the unhindered passage of clinically relevant dose levels through the microcirculation especially of the lungue, where they have to pass capillaries with diameters of around 4 μm. While smaller microbubbles rapidly passed through the microcirculation along with the red blood cells, larger microbubbles, however, were observed to coalesce and interrupt the blood flow. Whether this might influence the tissue oxygen tension is unclear up to now.To examine this question a bolus of 2.4 ml SonoVue™ was injected into the suprarenal aorta at a flow rate of 10 ml/s (a dosage usually applied in the clinic). The pO2 in the outer medulla of the kidney was continuously measured using a flexible pO2 microcatheter. In addition, the SonoVue™ injection and its passage through the renal vasculature were documented by the CEUS technology to assess whether the microbubbles passed the kidney.The study revealed that SonoVue™ induced no changes of the mean oxygen partial pressure in the outer medulla which confirms that these microbubbles on their way through the medullar capillaries did not hinder the co-flow of blood through the renal microvessels in a big animal model with a renal morphology and function comparable to human kidneys. These results demonstrate that the CEUS diagnostic itself did not influence the system to be examined which is a most important prerequisite for any diagnostic method.

Entities:  

Keywords:  CEUS; Iopromide; iodixanol; kidney; microcirculation

Mesh:

Substances:

Year:  2017        PMID: 28869455     DOI: 10.3233/CH-179201

Source DB:  PubMed          Journal:  Clin Hemorheol Microcirc        ISSN: 1386-0291            Impact factor:   2.375


  2 in total

1.  Contrast enhanced ultrasound (CEUS) to assess pleural pulmonal changes in severe COVID-19 infection: First results.

Authors:  E M Jung; C Stroszczynski; F Jung
Journal:  Clin Hemorheol Microcirc       Date:  2020       Impact factor: 2.375

2.  Contrast enhanced ultrasonography (CEUS) to detect abdominal microcirculatory disorders in severe cases of COVID-19 infection: First experience.

Authors:  E M Jung; C Stroszczynski; F Jung
Journal:  Clin Hemorheol Microcirc       Date:  2020       Impact factor: 2.375

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.