Literature DB >> 28868392

Secondary Aortoesophageal Fistula Due to Thoracic Aortic Stent Graft: Is There a Role for Endoscopic Intervention?

Sofia Vitor1, Liliane Meireles1, João Lopes1, Luís Carrilho Ribeiro1, José Velosa1.   

Abstract

Entities:  

Year:  2015        PMID: 28868392      PMCID: PMC5580158          DOI: 10.1016/j.jpge.2015.03.001

Source DB:  PubMed          Journal:  GE Port J Gastroenterol        ISSN: 2387-1954


× No keyword cloud information.
We present a case report of a 78-year-old man that was admitted in our Intensive Care Unit after an urgent surgical repair of a stent-grafting endoleak and an aortobronchial fistula. Five years before this event, he had been submitted to a thoracic endovascular repair of a descending thoracic aorta aneurysm. The immediate post-operative course was uneventful. Four days after surgery, the patient developed acute renal failure, elevated inflammatory markers, bacteremia and refractory shock, although he was under therapy with broad-spectrum antibiotics and there was no evidence of bleeding. A CT-scan revealed a thickened esophageal wall and small gas bubbles near the aortic stent graft suggesting an aortoesophageal fistula (Fig. 1). He was referred to our department for upper endoscopy and a fistula on the posterior surface of the middle third of the esophagus was recognized, through which the aortic stent was observed (Fig. 2). With the diagnosis of an aortoesophageal fistula secondary to the previous thoracic endovascular repair technique, esophageal stenting with a covered self-expanding esophageal stent with Ultraflex Esophageal NG 23 × 100 mm (Boston Scientific®, United States) was performed to help local infection control (Fig. 3). The medical treatment was optimized with intravenous proton pump inhibitors and parenteral nutrition, maintaining broad-spectrum antibiotics. In the next three weeks, no signs of hemorrhage or infection were noticed. The patient recovered from shock, with subsequent suspension of amines and ventilator support. Despite this clinical improvement, the patient died unexpectedly a few days before his scheduled surgery. The autopsy identified rupture of the aortic arch.
Figure 1

CT-scan image showing an esophagus thickened wall near the aortic stent graft.

Figure 2

Upper endoscopy showing an esophageal ulceration with the prosthetic aortic graft visible at the base which corresponds to an aortoesophageal fistula.

Figure 3

Upper endoscopy showing insertion of a covered self-expanding esophageal stent Ultraflex Esophageal NG, 23 × 100 mm (Boston Scientific®, United States).

CT-scan image showing an esophagus thickened wall near the aortic stent graft. Upper endoscopy showing an esophageal ulceration with the prosthetic aortic graft visible at the base which corresponds to an aortoesophageal fistula. Upper endoscopy showing insertion of a covered self-expanding esophageal stent Ultraflex Esophageal NG, 23 × 100 mm (Boston Scientific®, United States). Aortoesophageal fistula is a catastrophic complication of thoracic endovascular repair techniques with a reported incidence of 1.5%. Despite being the most frequent symptom, upper gastrointestinal bleeding is absent in some reported series in which new-onset fever and/or elevated inflammatory markers are the only clinical finding.1, 2 When a fistula is established, only surgery can offer definitive treatment. However, in most cases, patients are considered unsuitable for emergent invasive procedures due to their poor general condition.1, 2, 3, 4 In this particular case, we believe that esophageal stenting had a role in improving the septic shock and preventing bleeding. In the literature this endoscopic approach has been described more commonly in the presence of massive hemorrhage, and there is no bibliography specifying the secondary sepsis as indication for esophageal stenting.1, 4, 5 In conclusion, we highlight that esophageal stenting may play a role as a bridging procedure, improving the condition of these patients while awaiting surgery.

Ethical disclosures

Right to privacy and informed consent

The authors declare that no patient data appear in this article.

Confidentiality of data

The authors declare that no patient data appear in this article.

Protection of human and animal subjects

The authors declare that no experiments were performed on humans or animals for this study.

Conflicts of interest

The authors have no conflicts of interest to declare.
  5 in total

1.  Temporary stent placement in 2 cases of aortoesophageal fistula.

Authors:  Ina Zuber-Jerger; Ursula Hempel; Felix Rockmann; Frank Klebl
Journal:  Gastrointest Endosc       Date:  2008-06-09       Impact factor: 9.427

2.  Aorto-oesophageal and aortobronchial fistulae following thoracic endovascular aortic repair: a national survey.

Authors:  R Chiesa; G Melissano; E M Marone; M M Marrocco-Trischitta; A Kahlberg
Journal:  Eur J Vasc Endovasc Surg       Date:  2010-01-21       Impact factor: 7.069

3.  Successful management of aortoesophageal fistula by combining endoscopic cyanoacrylate injection and endovascular stent grafting.

Authors:  K-C Tseng; C-W Lin; J W-H Tan
Journal:  Endoscopy       Date:  2011-03-18       Impact factor: 10.093

4.  Aortoesophageal fistula after thoracic aortic stent-graft placement: a rare but catastrophic complication of a novel emerging technique.

Authors:  Holger Eggebrecht; Rajendra H Mehta; Alexander Dechene; Konstantinos Tsagakis; Hilmar Kühl; Sebastian Huptas; Guido Gerken; Heinz G Jakob; Raimund Erbel
Journal:  JACC Cardiovasc Interv       Date:  2009-06       Impact factor: 11.195

5.  Aortoesophageal fistula after endovascular aortic aneurysm repair of a mycotic thoracic aneurysm.

Authors:  Elizabeth Gavens; Zehra Zaidi; Wissam Al-Jundi; Palepu Kumar
Journal:  Int J Vasc Med       Date:  2011-09-06
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.