Literature DB >> 28868370

Single-balloon Enteroscopy Assisted Endoscopic Retrograde Cholangiopancreatography with the Rendezvous Technique.

Teresa Pinto Pais1, Rolando Pinho1, Luísa Proença1, Carlos Fernandes1, Iolanda Ribeiro1, Tiago Pereira2, João Carvalho1, José Fraga1.   

Abstract

Entities:  

Year:  2015        PMID: 28868370      PMCID: PMC5580103          DOI: 10.1016/j.jpge.2014.07.005

Source DB:  PubMed          Journal:  GE Port J Gastroenterol        ISSN: 2387-1954


× No keyword cloud information.
Endoscopic retrograde cholangiopancreatography (ERCP) in patients with surgically altered upper gastrointestinal anatomy such as a Roux-en-Y anastomosis is challenging. The use of balloon-assisted enteroscopy allows evaluation of the surgically excluded segment, access to the biliopancreatic tract and performance of endoscopic therapy. A 79-year-old female patient, with history of cholecistectomy (2005) and total gastrectomy with Roux-en-Y anastomosis for gastric cancer (pT2N0M0, 2007), suffered from recurrent episodes of cholangitis (2012). Abdominal ultrasonography revealed pronounced bile duct dilation (20 mm) caused by a large gallstone (17 mm) in the distal third of the common bile duct. After a failed standard ERCP, a percutaneous transhepatic biliary drainage (PTBD) was initially performed to relieve the obstruction. However, stone extraction was not accomplished. Therefore, she was referred to us for SBE-assisted ERCP, which was performed using a rendezvous technique, since there was a previously placed PTDB. The SBE (SIF-Q180 Olympus Medical Systems, Tokyo, Japan) was advanced to the afferent limb up to the papilla, where externalization of the percutaneously inserted guidewire was observed. A 4 Fr catheter (0.038″ 65 cm, Cordis) was placed over the wire and the percutaneous guidewire removed. A 500 cm 0.0035′ guidewire (Endoflex 21535500, Germany) was placed percutaneously through the catheter and grasped with a standard polypectomy snare. Then, biliary cannulation over the guidewire using the rendezvous technique was performed. Only limited sphincterotomy was achievable, due to the use of a longer (280 cm) conventional sphincterotome (Endoflex OE1042230DL-280, Germany) (Fig. 1). To safely perform a large sphincterotomy, a long Bilroth II-type sphincterome should be used, due to the retrograde approach. Subsequently, endoscopic papillary dilation was performed using a standard 12–15 mm balloon (CRE Boston Scientific, Tokyo, Japan), under direct visualization and radiologic control (Fig. 2). Peroral direct cholangioscopy (PDCS) was possible with the enteroscope, owing to pronounced biliary dilation. The large bile duct stone was removed under direct visualization using a retrieval balloon (Fig. 3). Finally, residual gallstones were excluded by PDCS and PTDB cholangiogram. There were no procedure-related complications. The patient had an uneventful recovery, and remains stable after 2-year follow-up.
Figure 1

Endoscopic sphincterotomy (A) and endoscopic papillary balloon dilation (B), performed via a retrograde approach.

Figure 2

Fluoroscopic image of the fully expanded dilation balloon across the papilla, and visualization of the guidewire placed percutaneously.

Figure 3

Direct cholangioscopy with the enteroscope showed a large bile duct stone (A), which was subsequently removed under direct visualization using a retrieval balloon (B).

Endoscopic sphincterotomy (A) and endoscopic papillary balloon dilation (B), performed via a retrograde approach. Fluoroscopic image of the fully expanded dilation balloon across the papilla, and visualization of the guidewire placed percutaneously. Direct cholangioscopy with the enteroscope showed a large bile duct stone (A), which was subsequently removed under direct visualization using a retrieval balloon (B). Balloon-assisted enteroscopy–ERCP is now an accepted interventional modality in patients with complex postsurgical anatomy, such as Roux-en-Y anatomy. The enteroscope allows deep insertion into the small bowel and access to the papilla and the biliary tract. However, cannulation and sphincterotomy are technically difficult with a forward-viewing instrument, via retrograde approach. Additionally, the use of devices, such as dilating balloons, through a narrow and long working channel is limited. Also, the device maneuverability is difficult, particularly from looping and twisting scope position.2, 3 A systematic review by Skinner et al. reported an overall ERCP success of approximately 74%, due to these limitations. Traditionally used in conventional ERCP, the rendezvous technique has improved the success rate of biliary cannulation in enteroscope-assisted ERCP. The SBE–ERCP rendezvous technique presented herein allowed successful therapeutic techniques such as sphincterotomy, papillary balloon dilation and biliary stone extraction, under direct endoscopic view. Our case, as other recent reports, illustrates the gradual disappearance of barriers for endoscopic biliary interventions in patients with altered upper gastrointestinal tract anatomy.

Ethical disclosures

Protection of human and animal subjects

The authors declare that no experiments were performed on humans or animals for this study.

Confidentiality of data

The authors declare that they have followed the protocols of their work center on the publication of patient data.

Right to privacy and informed consent

The authors have obtained the written informed consent of the patients or subjects mentioned in the article. The corresponding author is in possession of this document.

Conflicts of interest

The authors have no conflicts of interest to declare.
  5 in total

1.  Percutaneous balloon dilation and placement of endoscopic biliary stent by using the double-balloon enteroscopy ERCP rendezvous technique.

Authors:  Klaus Mönkemüller; Brendan McGuire; C Mel Wilcox; Jayapal Ramesh; Derek DuBay; Devin Eckhoff
Journal:  Gastrointest Endosc       Date:  2013-08       Impact factor: 9.427

2.  Double-balloon enteroscopy-ERCP rendezvous technique.

Authors:  K Mönkemüller; D Popa; B McGuire; J Ramesh; C M Wilcox
Journal:  Endoscopy       Date:  2013-10-22       Impact factor: 10.093

3.  Biliary self-expandable metallic stent using single balloon enteroscopy assisted ERCP--overcoming limitations of current accessories.

Authors:  Rolando Pinho; Luisa Proença; Luis Alberto; Joao Carvalho; Teresa Pinto-Pais; Carlos Fernandes; Iolanda Ribeiro; Tiago Pereira; Jose Fraga
Journal:  Rev Esp Enferm Dig       Date:  2013-10       Impact factor: 2.086

4.  Single- and double-balloon enteroscopy-assisted endoscopic retrograde cholangiopancreatography in patients with Roux-en-Y plus hepaticojejunostomy anastomosis and Whipple resection.

Authors:  Fumihide Itokawa; Takao Itoi; Kentaro Ishii; Atsushi Sofuni; Fuminori Moriyasu
Journal:  Dig Endosc       Date:  2014-04       Impact factor: 7.559

Review 5.  ERCP with the overtube-assisted enteroscopy technique: a systematic review.

Authors:  Matthew Skinner; Daniel Popa; Helmut Neumann; C Mel Wilcox; Klaus Mönkemüller
Journal:  Endoscopy       Date:  2014-05-16       Impact factor: 10.093

  5 in total
  2 in total

1.  Percutaneous Transhepatic Cholangiography Rendez-Vous Procedure to Reach the Duodenum for Enteroscopy-Assisted Endoscopic Retrograde Cholangiopancreatography in Surgically Altered Anatomy.

Authors:  Ana Ponte; Rolando Pinho; Luísa Proença; Joana Silva; Jaime Rodrigues; Mafalda Sousa; Tiago Pereira; João Carvalho
Journal:  GE Port J Gastroenterol       Date:  2017-06-23

2.  The Vanishing Frontiers of Therapeutic Enteroscopy.

Authors:  Rolando Pinho
Journal:  GE Port J Gastroenterol       Date:  2015-07-06
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.