Literature DB >> 28867380

Homemade fenestrated stent-graft for thoracic endovascular aortic repair of zone 2 aortic lesions.

Ludovic Canaud1, Kiyofumi Morishita2, Thomas Gandet3, Julien Sfeir3, Sebastien Bommart3, Pierre Alric3, Marcello Mandelli4.   

Abstract

OBJECTIVE: The aim of this retrospective analysis was to evaluate the outcomes of homemade fenestrated stent-grafts for thoracic endovascular aortic repair of zone 2 aortic lesions.
METHODS: From November 2013 to January 2017, 24 patients underwent thoracic endovascular aortic repair with left subclavian artery revascularization using a homemade fenestrated stent-graft to preserve the patency of the left subclavian artery. Elective cases accounted for 54% (n = 13) of the sample. Indications included acute complicated type B aortic dissection (n = 9), degenerative aneurysm (n = 9), penetrating aortic ulcer (n = 5), and intramural hematoma (n = 1). Routine postoperative follow-up imaging with computed tomography angiography was performed to assess thoracic endovascular aortic repair and left subclavian artery fenestration patency and endoleak.
RESULTS: Median duration for stent-graft modification was 16 minutes (range, 14-17 minutes). The technical success rate was 100%. One patient had a distal type I endoleak requiring additional stent-graft placement. One patient had partial coverage of the left common carotid artery requiring left common carotid artery stenting. One patient had a stroke without permanent sequelae (4.1%). Overall mortality was 0%. All left subclavian arteries were patent. Two type III endoleaks required additional left subclavian artery covered stent placement. One type II endoleak is currently observed. During a mean follow-up of 13.2 ± 2 months, there were no conversions to open surgical repair, aortic rupture, paraplegia, or retrograde dissection.
CONCLUSIONS: The use of a homemade fenestrated stent-graft for thoracic endovascular aortic repair of zone 2 aortic lesions is both feasible and effective for left subclavian artery revascularization during thoracic endovascular aortic repair involving a spectrum of thoracic aortic pathology. Durability concerns will need to be assessed in additional studies with long-term follow-up.
Copyright © 2017 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  physician-modified thoracic stent-grafts; thoracic endovascular aortic repair

Mesh:

Year:  2017        PMID: 28867380     DOI: 10.1016/j.jtcvs.2017.07.045

Source DB:  PubMed          Journal:  J Thorac Cardiovasc Surg        ISSN: 0022-5223            Impact factor:   5.209


  7 in total

1.  Physician-Modified Endovascular Grafts for Zone-2 Thoracic Endovascular Aortic Repair.

Authors:  André B Queiroz; Jackson B Lopes; Vanessa P Santos; Pedro B A F Cruz; Ronald J R Fidelis; José S Araújo Filho; Luiz C S Passos
Journal:  Aorta (Stamford)       Date:  2022-05-31

2.  Outcomes of single physician-modified fenestrated stent grafts for endovascular repair of thoracic aortic lesions involving the distal aortic arch.

Authors:  Jiechang Zhu; Chao Ma; Xiangchen Dai; Zheng Wang; Hailun Fan; Zhou Feng; Yudong Luo; Yiwei Zhang; Fanguo Hu
Journal:  Interact Cardiovasc Thorac Surg       Date:  2021-04-19

Review 3.  Narrative review on endovascular techniques for left subclavian artery revascularization during thoracic endovascular aortic repair and risk factors for postoperative stroke.

Authors:  Mario D'Oria; Kevin Mani; Randall DeMartino; Martin Czerny; Konstantinos P Donas; Anders Wanhainen; Sandro Lepidi
Journal:  Interact Cardiovasc Thorac Surg       Date:  2021-05-10

4.  Surgeon-modified fenestrated stent graft deployment in type B aortic dissection.

Authors:  Hakkı Zafer İşcan; Ertekin Utku Ünal
Journal:  Turk Gogus Kalp Damar Cerrahisi Derg       Date:  2021-04-26       Impact factor: 0.332

5.  Endovascular treatment for aortic arch pathologies: chimney, on-the-table fenestration, and in-situ fenestration techniques.

Authors:  Chang Shu; Bowen Fan; Mingyao Luo; Quanming Li; Kun Fang; Ming Li; Xin Li; Hao He; Tun Wang; Chenzi Yang; Yunfei Xue; Haoyu Gao; Jiawei Zhao
Journal:  J Thorac Dis       Date:  2020-04       Impact factor: 2.895

6.  A cadaveric perfused model with antegrade arteriovenous pulsatile circulation: a new tool for teaching endovascular skills.

Authors:  Ahmad Rifahi; Robin Chastant; Catherine Forest-Nault; Elena Refet-Mollof; Aymeric Guy; Emmanuel Charbonney; Gilles Bronchti; Guillaume Febrer
Journal:  Can J Surg       Date:  2022-07-05       Impact factor: 2.840

7.  Single-center experience with a unibody single-branched stent graft for zone 2 thoracic endovascular aortic repair.

Authors:  Xiang Kong; Peng Ruan; Jiquan Yu; Tianshu Chu; Lei Gao; Hui Jiang; Jianjun Ge
Journal:  Front Cardiovasc Med       Date:  2022-09-09
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.