Literature DB >> 28867371

The suture retention test, revisited and revised.

M Pensalfini1, S Meneghello2, V Lintas3, K Bircher2, A E Ehret4, E Mazza4.   

Abstract

A systematic investigation of the factors affecting the suture retention test is performed. The specimen width w and the distance a of the suture bite from the specimen free edge emerge as the most influential geometrical parameters. A conservative approach for the quantification of suture retention strength is identified, based on the use of a camera to monitor the incipient failure and detect the instant of earliest crack propagation. The corresponding critical force, called break starting strength, is extremely robust against test parameter variations and its dependence on the specimen geometry becomes negligible when a≥ 2mm and w≥ 10mm. Comparison of suture retention and mode I crack opening tests reveals a linear correlation between break starting strength and tearing energy. This suggests that the defect created by the needle and the load applied by the suture thread lead to a fracture mechanics problem, which dominates the initiation of failure.
Copyright © 2017 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Biomaterial characterization; Break starting strength; Fracture mechanics; Soft tissues; Suture retention

Mesh:

Substances:

Year:  2017        PMID: 28867371     DOI: 10.1016/j.jmbbm.2017.08.021

Source DB:  PubMed          Journal:  J Mech Behav Biomed Mater        ISSN: 1878-0180


  8 in total

1.  On the defect tolerance of fetal membranes.

Authors:  Kevin Bircher; Alexander E Ehret; Deborah Spiess; Martin Ehrbar; Ana Paula Simões-Wüst; Nicole Ochsenbein-Kölble; Roland Zimmermann; Edoardo Mazza
Journal:  Interface Focus       Date:  2019-08-16       Impact factor: 3.906

2.  Standardized suturing can prevent slackening or bursting suture lines in midline abdominal incisions and defects.

Authors:  C Lesch; K Uhr; M Vollmer; R Raschidi; R Nessel; F Kallinowski
Journal:  Hernia       Date:  2022-08-23       Impact factor: 2.920

3.  A Route to Translate a Silk-Based Medical Device from Lab to Clinic: The Silk Biomaterials Srl Experience.

Authors:  Giulia Alessandra Bassani; Valentina Vincoli; Marco Biagiotti; Elisa Valsecchi; Marta Virginia Zucca; Claudia Clavelli; Antonio Alessandrino; Giuliano Freddi
Journal:  Insects       Date:  2022-02-21       Impact factor: 2.769

4.  Development of a Novel Human Cell-Derived Tissue-Engineered Heart Valve for Transcatheter Aortic Valve Replacement: an In Vitro and In Vivo Feasibility Study.

Authors:  V Lintas; E S Fioretta; S E Motta; P E Dijkman; M Pensalfini; E Mazza; E Caliskan; H Rodriguez; M Lipiski; M Sauer; N Cesarovic; S P Hoerstrup; M Y Emmert
Journal:  J Cardiovasc Transl Res       Date:  2018-08-13       Impact factor: 4.132

5.  Tear resistance of soft collagenous tissues.

Authors:  Kevin Bircher; Manuel Zündel; Marco Pensalfini; Alexander E Ehret; Edoardo Mazza
Journal:  Nat Commun       Date:  2019-02-15       Impact factor: 14.919

6.  Improvement of the Physical Properties of Guided Bone Regeneration Membrane from Porcine Pericardium by Polyphenols-Rich Pomace Extract.

Authors:  Nazario Russo; Clara Cassinelli; Elisa Torre; Marco Morra; Giorgio Iviglia
Journal:  Materials (Basel)       Date:  2019-08-12       Impact factor: 3.623

7.  The application of tissue-engineered fish swim bladder vascular graft.

Authors:  Hualong Bai; Peng Sun; Haoliang Wu; Shunbo Wei; Boao Xie; Wang Wang; Yachen Hou; Jing'an Li; Alan Dardik; Zhuo Li
Journal:  Commun Biol       Date:  2021-10-05

8.  Suture retention strength of P(LLA-CL) tissue-engineered vascular grafts.

Authors:  Xin Meng; Xiaofeng Wang; Yongchao Jiang; Bo Zhang; Kun Li; Qian Li
Journal:  RSC Adv       Date:  2019-07-09       Impact factor: 4.036

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.