Literature DB >> 28866284

Intracardiac electrocardiographic assessment of precordial TASER shocks in human subjects: A pilot study.

Jason P Stopyra1, James E Winslow2, David M Fitzgerald3, William P Bozeman2.   

Abstract

BACKGROUND: Case reports of cardiac arrest in temporal proximity to Conducted Electrical Weapon(CEW) exposure raise legitimate concerns about this as a rare possibility. In this pilot study, we respectfully navigate the oversight and regulatory hurdles and demonstrate the intra-shock electrocardiographic effects of an intentional transcardiac CEW discharge using subcutaneous probes placed directly across the precordium of patients with a previously implanted intracardiac EKG sensing lead.
METHODS: Adults scheduled to undergo diagnostic EP studies or replacement of an implanted cardiac device were enrolled. Sterile subcutaneous electrodes were placed at the right sternoclavicular junction and the left lower costal margin at the midclavicular line. A standard police issue TASER Model X26 CEW was attached to the subcutaneous electrodes and a 5 s discharge was delivered. Continuous surface and intracardiac EKG monitoring was performed.
RESULTS: A total of 157 subjects were reviewed for possible inclusion and 21 were interviewed. Among these, 4 subjects agreed and completed the study protocol. All subjects tolerated the 5 s CEW discharge without clinical complications. There were no significant changes in mean heart rate or blood pressure. Interrogation of the devices after CEW discharge revealed no ventricular pacing, dysrhythmias, damage or interference with the implanted devices.
CONCLUSIONS: In this pilot study, we have successfully navigated the regulatory hurdles and demonstrated the feasibility of performing intracardiac EKG recording during intentional precordial CEW discharges in humans. While no CEW-associated dysrhythmias were noted, the size of this preliminary dataset precludes making conclusions about the risk of such events. Larger studies are warranted and should consider exploring variations of the CEW electrode position in relation to the cardiac silhouette.
Copyright © 2017. Published by Elsevier Ltd.

Entities:  

Keywords:  CEW; ECG; EKG; Electrophysiology; TASER

Mesh:

Year:  2017        PMID: 28866284     DOI: 10.1016/j.jflm.2017.08.004

Source DB:  PubMed          Journal:  J Forensic Leg Med        ISSN: 1752-928X            Impact factor:   1.614


  2 in total

Review 1.  Cardiac and skeletal muscle effects of electrical weapons : A review of human and animal studies.

Authors:  Sebastian N Kunz; Hugh Calkins; Jiri Adamec; Mark W Kroll
Journal:  Forensic Sci Med Pathol       Date:  2018-06-28       Impact factor: 2.007

2.  Human Health Risks of Conducted Electrical Weapon Exposure: A Systematic Review.

Authors:  Christos Baliatsas; Jenny Gerbecks; Michel L A Dückers; C Joris Yzermans
Journal:  JAMA Netw Open       Date:  2021-02-01
  2 in total